Use Table 1 to find the condition that applies:
| AC INPUT GOOD | UEPO LOOP GOOD | PPS Display Panel | Action |
|---|---|---|---|
| On | Off | Ignore | Normal condition, continue with the next step |
| On | On | Ignore | UEPO fault, go to MAP21F0 UEPO loop good LED should be off |
| Off | Off | Ignore | Input power fault, go to MAP2050 Loss of AC Input to a single primary power supply Note: If
both PPSs are failing, then repeat the customer voltage checks done
previously.
|
| AC INPUT GOOD | UEPO LOOP GOOD | PPS Display Panel | Action |
|---|---|---|---|
| On | On | Blank, U0, XC, XE or XF Note: Some
levels of PPS firmware cause an XC error code to be displayed. This
is a false error. The condition remains until the DDM power supply
is turned on in a later step.
The XE and XF status report that the PPSs are not communicating with the RPC cards. This is expected as the expansion rack power control cables from the PPS to Rack-1 RPC card cables have not yet been connected. No action is required. Continue with the next step. |
Normal condition, continue with the next step. |
| On | On | Two-character status code other than Blank, U0, XC, XE or XF. | Go to MAP21A0 PPS fault isolation during install |
| On | Off | Ignore the display's status code. | This is a UEPO fault. Go to MAP21E0 UEPO Loop Good LED should be on |