About this task
The UEPO switch has two sets of contacts, one set of contacts
for each
PPS.
Each set of contacts has a two wire UEPO loop cable that goes to the
PPS sequencer
module J4 connector. When the UEPO switch is on (normal operation),
the circuit is closed and the LED should be lit. When the UEPO switch
is tripped off, the circuit is open and the LED should be off.