DS8000 Service Documentation Version 6.3.3

MAP1245 Finding FRUs by using location codes

How to convert a location code to the storage facility location that contains the FRU or function.

In most cases, any FRU listed in a serviceable event includes a location code. Cables are a special case because they do not have their own location code. Cables that can be identified as failing by the microcode use the location of the FRU connectors they connect to. This means that those cables have two location codes, one for each end of the cable. For a Y cable in the power system, there will be three location codes. Cables that are not reported directly by the microcode are determined by guided isolation procedures.

MAP1245 Section-1

  1. Location codes have two parts:
    • The "MTMS" (machine type, model, serial number) of the rack or enclosure within the rack
    • The physical location within the rack or enclosure
    Example of location code: 2107.D01.1300177-P1-C2-T3
    • The "MTMS"(machine type, model, serial number):
      • 2107.D01 = storage enclosure (machine type/model)
      • 1300177 = storage enclosure serial number (visible on the bar code label)
    • The physical location:
      • P1- = Planar 1
      • C2- = FCIC card 2 (second from left in storage enclosure)
      • T3 = FC-AL cable connector (third FC-AL cable connector from left on FCIC card)
  2. To convert the MTMS or location code to the FRU type or enclosure type, select the following conditions that apply:
    • For rack models 951, 95E, use Table 1
    • For rack models 941, 94E, use Table 2
Table 1. Location code conversions for rack Model 951, 95E
MTMS or location code Description MTMS label location Second part of Location Code
242n.951.ssssss0 Storage Facility On the rack 1 front door, just above the latch handle. Also on rack UEPO panel (behind front door), to left of UEPO switch.

(The SF is not a physical FRU, it is a managed entity that contains one or more racks).

 

2107.951.ssssss1

Storage Facility Image (SFI) (The SFI is not a physical FRU; it is a logical partition on the CEC enclosure.)  
242n.AE1.ssssss0 (Model 951) Storage Facility Rack (base) Not on label (obtained by substituting AE1 for 951 in Storage Facility MTMS). Rack power and cooling location codes (Models 951, 95E)
242n.AB1.ssssss0 (Model 951) Storage Facility Rack (base)
(business class cabling)
Not on label (obtained by substituting AB1 for 951 in Storage Facility MTMS). Rack power and cooling location codes (Models 951, 95E)
242n.95E.ssssss0 (Model 951) Storage Facility Rack (expansion)
(Rack-2, with I/O enclosures)
On the rack front door, just above the latch handle. Also on rack UEPO panel (behind front door), to left of UEPO switch. Rack power and cooling location codes (Models 951, 95E)
242n.95F.ssssss0 (Model 951) Storage Facility Rack (expansion)
(without I/O enclosures)
Not on label - obtained by substituting 95F for 95E in expansion rack MTMS, which is on the rack front door, just above the latch handle. Also on rack UEPO panel (behind front door), to left of UEPO switch. Rack power and cooling location codes (Models 951, 95E)

U242n-mmm.sssssss-Ax
(x=1, 2, 3, 4)

)
Ethernet switch tray fan On the rack front door, just above the latch handle. Rack power and cooling location codes (Models 951, 95E)

U242n-mmm.sssssss-Cx
(x=1, 2)

Rack Power Control (RPC) card On the rack front door, just above the latch handle. Rack power and cooling location codes (Models 951, 95E)

U242n.mmm.sssssss-Cx
(x=5)

Rack identity card On the rack front door, just above the latch handle. Rack power and cooling location codes (Models 951, 95E)

U242n.mmm.sssssssCx
(x=6)

Local/Remote or zSeries switch card On the rack front door, just above the latch handle. Rack power and cooling location codes (Models 951, 95E)

U242n.mmm.sssssss-Ex
(x=1, 2)

Primary Power Supply (PPS) On the rack front door, just above the latch handle. Rack power and cooling location codes (Models 951, 95E)

U242n.mmm.sssssss-Ex
(x=10, 11, 12)

Battery module enclosure On the rack front door, just above the latch handle. Rack power and cooling location codes (Models 951, 95E)

U242n.mmm.sssssss-E2x
(x=1, 2, 3, 4, 5, 6)

Power distribution unit (PDU) On the rack front door, just above the latch handle. Rack power and cooling location codes (Models 951, 95E)
U2107.D02.sssssss (Model 951) Storage enclosure
  • On the front of the storage enclosure, at the far right on the mounting flange.
  • On the rear of the storage enclosure, in the middle between the left and right FCIC cards.
Storage enclosure location codes (Models 951, 95E)
9117-MMA*sssssss Server model (also called "system" or "CEC complex")
(CEC complex is 1 or more than 1 CEC enclosure cabled together and controlled by the service processor in the first CEC enclosure)
On the front of the CEC enclosure, on the operator panel. CEC enclosure location codes (Models 941, 951)
U789D.001.sssssss CEC enclosure feature code.model (also called enclosure type.model)
(a CEC complex might have more than one CEC enclosure, each with a unique ssssss)
On the front of the CEC enclosure, at the far right, in between the rack mounting screws (in a vertical orientation). CEC enclosure location codes (Models 941, 951)
U1400.rBn.sssssss I/O enclosure On the front of the I/O enclosure, at the bottom of the left I/O enclosure power supply. I/O enclosure location codes (Models 951, 95E)
8676.mmm.sssssss x335 management console On the front of the HMC server, at the far right, near the thumb screw (in a vertical orientation). Management console (MC) server location codes (Models 961, 951, 941)
8837.mmm.sssssss x3550 management console On the front of the HMC server, at the far right, near the thumb screw (in a vertical orientation). Management console (MC) server location codes (Models 961, 951, 941)
7978.mmm.sssssss x336 management console On the front of the HMC server, at the far right, near the thumb screw (in a vertical orientation). Management console (MC) server location codes (Models 961, 951, 941)
4061.mmm.sssssss ThinkPad W500 laptop management console On the bottom of the ThinkPad laptop. Management console (MC) server location codes (Models 961, 951, 941)
4349.mmm.sssssss ThinkPad T510 laptop management console On the bottom of the ThinkPad laptop. Management console (MC) server location codes (Models 961, 951, 941)
4242.mmm.sssssss ThinkPad T520 laptop management console On the bottom of the ThinkPad laptop. Management console (MC) server location codes (Models 961, 951, 941)
Table 2. Location code conversions for rack Models 941, 94E
MTMS or location code Description MTMS label location Second part of Location Code
242n.941.ssssss0 Storage Facility On the Rack-1 front or rear door, just above the latch handle. Also, on Rack-1 UEPO panel (behind front door), above power and attention LEDs.

(The SF is not a physical FRU; it is Rack-1 and any attached expansion racks.)

 

2107.941.ssssssy
(y=1, 2)

Storage Facility Image (SFI) (The SFI is not a physical FRU; it is a logical partition on the CEC enclosure.)  
242n.A01.ssssss0 Storage Facility Rack (base) Not on label (obtained by substituting A01 for 941 in Storage Facility MTMS). Rack power and cooling location codes (Models 941, 94E)

242n.94E.ssssss0
2nnn.92E.ssssss0

Storage Facility Rack (expansion) On the rack front or rear door, just above the latch handle.
Also on rack UEPO panel (behind front door), above power and attention LEDs.

Model 92E only: On the rack operator panel below the UEPO red switch cover.

Rack power and cooling location codes (Models 941, 94E)

U242n.mmm.sssssss-Ax
(x=1, 2, 3)

DASD Fan Trays On the rack front or rear door, just above the latch handle. Rack power and cooling location codes (Models 941, 94E)

U242n.mmm.sssssss-Cx
(x=1, 2)

Rack Power Control (RPC) card On the rack front or rear door, just above the latch handle. Rack power and cooling location codes (Models 941, 94E)

U242n.mmm.sssssss-Cx
(x=3, 4)

Fan sense card On the rack front or rear door, just above the latch handle. Rack power and cooling location codes (Models 941, 94E)

U242n.mmm.sssssss-Cx
(x=5)

Rack identity card On the rack front or rear door, just above the latch handle. Rack power and cooling location codes (Models 941, 94E)

U242n.mmm.sssssss-Cx
(x=6)

Local/Remote or zSeries switch card On the rack front or rear door, just above the latch handle. Rack power and cooling location codes (Models 941, 94E)

U242n.mmm.sssssss-Ex
(x=1, 2)

Primary Power Supply (PPS) On the rack front or rear door, just above the latch handle. Rack power and cooling location codes (Models 941, 94E)

U242n.mmm.sssssss-Ex
(x=10, 11, 12)

Battery module enclosure On the rack front or rear door, just above the latch handle. Rack power and cooling location codes (Models 941, 94E)
U2107.D01.sssssss Storage enclosure On the front of the storage enclosure, at the far right in between the rack mounting screws. Storage enclosure location codes (Models 941, 94E)
9117-MMA*sssssss Server model (also called "system" or "CEC complex")
(CEC complex is 1 or more than 1 CEC enclosure cabled together and controlled by the service processor in the first CEC enclosure)
On the front of the CEC enclosure, on the operator panel. CEC enclosure location codes (Models 941, 951)
U789D.001.sssssss CEC enclosure feature code.model (also called enclosure type.model)
(a CEC complex might have more than one CEC enclosure, each with a unique ssssss)
On the front of the CEC enclosure, at the far right, in between the rack mounting screws (in a vertical orientation). CEC enclosure location codes (Models 941, 951)
U1400.rBn.sssssss I/O enclosure On the front of the I/O enclosure, at the bottom of the left I/O enclosure power supply. I/O enclosure location codes (Models 941, 94E)
8676.mmm.sssssss x335 management console On the front of the HMC server, at the far right, near the thumb screw (in a vertical orientation). Management console (MC) server location codes (Models 961, 951, 941)
8837.mmm.sssssss x3550 management console On the front of the HMC server, at the far right, near the thumb screw (in a vertical orientation). Management console (MC) server location codes (Models 961, 951, 941)
7978.mmm.sssssss x336 management console On the front of the HMC server, at the far right, near the thumb screw (in a vertical orientation). Management console (MC) server location codes (Models 961, 951, 941)
4061.mmm.sssssss ThinkPad W500 laptop management console On the bottom of the ThinkPad laptop. Management console (MC) server location codes (Models 961, 951, 941)
4349.mmm.sssssss ThinkPad T510 laptop management console On the bottom of the ThinkPad laptop. Management console (MC) server location codes (Models 961, 951, 941)
4242.mmm.sssssss ThinkPad T520 laptop management console On the bottom of the ThinkPad laptop. Management console (MC) server location codes (Models 961, 951, 941)