Does the serviceable event FRU list
that sent you to this MAP contain any FRUs, other than the service
processor card, that are not replaced yet?
Yes, exit this isolation procedure to replace the
non-service processor card FRUs one at a time until the problem is
resolved. If you cannot replace the FRU by selecting it in the FRU
list, refer to MAP1230 Replace a FRU without using a serviceable event.
No, there are no non-service processor card FRUs
to be replaced, go to the next step.
Are you going through this isolation
procedure for the first time?
Yes, close this serviceable event and exit this isolation
procedure. If there is a problem with the service processor firmware,
a new serviceable event is
opened.
No, go to the next step.
The error is assumed
to be in the service processor firmware. There is no DS8000® service
representative procedure to reload the same level of firmware on the CEC enclosureservice processor. Instead,
replace the service processor;
go to MAP1215 Replace a FRU.