A power supply or regulator overcurrent fault is occurring
in the CEC enclosure.
Before you begin
Before servicing the system, refer to the other PWR19xx MAPs
for important safety information.
PWR1904 Section-1
Before you begin
Note: Storage complex repair actions must always be managed from the management
console. To replace any FRUs identified in this
procedure, use Storage
Facility Management > storage facility > Exchange Parts. If the FRUs are listed in
this or another Serviceable Event, select them from there.
Power off the failing CEC enclosure indicated
in the problem. Use HMC > Service
Applications > Service Focal Point > Service Utilities > Storage Facility
Systems Management > Deactivate a System then
Power Off a System.
Power on the CEC enclosure. Use HMC > Service Applications > Service Focal Point > Service Utilities > Storage Facility Systems Management > Power
On a System.
Has the problem been resolved?
Yes, the problem is resolved, continue with step 17.
No, repeat step 3 and
replace the next memory DIMM.
Perform the following steps:
Power off the failing CEC enclosure indicated
in the problem. Use HMC > Service
Applications > Service Focal Point > Service Utilities > Storage Facility
Systems Management > Deactivate a System then
Power Off a System.
Power on the CEC enclosure. Use HMC > Service Applications > Service Focal Point > Service Utilities > Storage Facility Systems Management > Power
On a System.
Has the problem been resolved?
Yes, the problem has been resolved. Continue with step 17.
No, repeat step 4 and
replace the next processor card.
Perform the following steps:
Power off the failing CEC enclosure indicated
in the problem. Use HMC > Service
Applications > Service Focal Point > Service Utilities > Storage Facility
Systems Management > Deactivate a System then
Power Off a System .
Remove and label all PCI cards that are installed.
Reconnect the power cable to the CEC power supplies
E1 and E2.
Power on the CEC enclosure. Use HMC > Service Applications > Service Focal Point > Service Utilities > Storage Facility Systems Management > Power
On a System.
If you have not done so already, power on
the CEC enclosure,
close associated problems and return it to the customer. Perform the
following:
Power on the storage facility. Use HMC > Service Applications > Service Focal Point > Service Utilities > Storage Facility Systems Management > Power
On a System and Reactivate a System
To close any associated problems, use HMC > Service Applications > Service Focal Point > Manage Serviceable
Events.