SRCs in the range BE1110xx are used to report problems that were detected by the SFI LPAR dual hard-drive process. In some cases they will be logged normally during a repair action and in some cases they will appear in conjunction with other SRCs.
| SRC | Action |
|---|---|
| BE111050 | Description: The SFI LPAR hard-disk drives
are not mirrored, and the automatic mirroring function has been disabled. Action: Go to step 4. |
| BE111051 | Description: An SFI LPAR hard-drive has
failed. Action: Notes: This
SRC may be logged if a hard-drive repair action was started but not
completed.
Note: Next level should check the dual hard-drive status
with lsdev -C | grep hdisk. If either
hard drive displays status as defined, it should be replaced. To replace
a FRU that is not listed in a serviceable event, use
the HMC Exchange Parts menu option. See MAP1215 Replace a FRU.
|
| BE111052 | Description: An SFI LPAR dual hard-drive
Mirror operation failed. Action: Go to step 4. |
| BE111053 | Description: An SFI LPAR dual hard-drive
Unmirror operation failed.
Action: Notes: This SRC may have been created during
a repair action.
|
| BE111057 | Description: The capacity of the disk drive being installed is less than the capacity of the original disk drive. Action: Use the repair process to replace the disk drive with one of proper capacity. |
| BE111058 | Description: An SFI LPAR dual hard-drive
Mirroring cleanup operation failed. Action: Contact your next level of support. |
| BE111059 | Description: The partition's file system
is full. Action: This can occur if a CD or DVD media is discovered in the in the CEC enclosure DVD drive. Remove the media. If no media is present, contact your next level of support. |
| BE11105A | Description: An illegal SFI dual hard-drive
operation was attempted. Action: If all repair actions were being done through the maintenance package, then this is an unexpected condition. Contact your next level of support. |
| BE11105B | Description: An SFI LPAR dual hard-drive
command failed. Action: Go to step 3. |
| BE11105C | Description: The mirrored SFI LPAR dual
hard-drives cannot be synchronized. Action: Go to step 4. |
| BE11105D | Description: An SFI LPAR dual hard-drive
drive bosboot command failed. Action: Go to step 3. |
| BE11105F | Description: An SFI LPAR dual hard-drive is failing. The other is not mirrored so cannot be used. The AIX and Licensed Internal Code will have to be reloaded. Go to MAP4020 Hard disk drive build process for both boot drives in a storage facility image LPAR. |
| BE111060 | Description: The SFI LPAR IML'd from
the second hard disk drive in the bootlist, instead of the first.
Action: Go to MAP43C0 SFI LPAR IML from Second Hard Disk Drive. |
| BE11106F | Description: One of the FHD logical volumes
is failing. Action: Go to step 5. |