Explanation
Platform LIC detected an error
Response
Abnormal or unexpected HSL OptiConnect disconnection from a
remote system or partition.
The local system or partition disconnected from a remote
system or partition due to an unexpected event or failure.
Licensed Internal Code will attempt to recover from the
error. Intervention at the local or remote system or
partition might be required.
Possible causes include time out, hang, or hardware failure.
The problem may be with the local system or partition or the
remote system or partition.
If a complete RIO or HSL loop did not exist before this
error
occurred, the cause of this error might be a failure or
power down in a RIO or HSL component between the local
system
or
partition and the remote system or partition. Check for SRCs
with FRUs that indicate problems with the following:
- RIO or HSL cables
- The RIO or HSL I/Oidge
- Power in an expansion I/O tower or unit on this
loop
On the local system or partition, examine the SAL or
serviceable event view. Look for failures on the same loop
or with the RIO or HSL controller that occurred at
approximately the same time as this error.
Examine the remote system or partition for problems. Correct
any RIO or HSL controller problems you find with the
remote and local
systems or partitions.
If you find no problems with either the local or the remote
systems or partitions, collect all the PAL information for
this failure on both systems. Be sure to record all words in
the SRC. Contact your next level of support.
Problem determination
No action is required.