Explanation
Platform LIC detected an error
Response
Abnormal or unexpected HSL OptiConnect disconnection from a
remote system or partition.
The local system or partition disconnected from a remote
system or partition due to an unexpected event or failure.
The problem, which most likely originates with the remote
system or partition, probably requires intervention at the
remote system. Examine both the local and remote HSL
OptiConnected systems or partitions for problems on this
RIO or HSL
loop.
Possible reasons include: A fatal software or hardware error
in the remote system or partition, or a power failure in the
remote system.
If a complete RIO or HSL loop did not exist before this
error
occurred, the cause of this error might be a failure or
power down in a RIO or HSL component between the local
system
or
partition and the remote system or partition. Check for a
problem with the following:
- A RIO or HSL cable
- The RIO or HSL I/Oidge
- Power in an expansion I/O tower or unit on this
loop
On the local system or partition, examine the Service Action
Log (SAL) or serviceable event view. Look for RIO or HSL
failures
that occurred on the same RIO or HSL loop at approximately
the
same
time as this error.
Examine the remote system or partition for problems. If the
remote system or partition is powered on and IPL'd, examine
the SAL or serviceable event view on the remote system or
partition. Look for problems on the same RIO or HSL loop
that
occurred at approximately the same time as this error.
Correct any problems you find with the remote and local
systems or partitions that happened at approximately the
same time and involve HSL Opticonnect or RIO or HSL loop
components.
When the remote system is IPL'd, it will automatically
reconnect with this system or partition. If you find no
problems with either the local or the remote systems or
partitions, collect all the Product Activity Log (PAL)
information for this failure on both systems. Be sure to
record all words in the SRC. Contact your next level of
support.
Problem determination
No action is required.