Wait a maximum of 1 hour 45 minutes (1:45) for a series of status screens
to be displayed. Does the HMC display the following message?
The
installation is now complete. Return to the MES or installation instructions. - Yes. The verify process has successfully completed. Click
Next and go to the next step.
- No. If the verify process does not complete successfully and
an exception screen is displayed, call the next level of support.
Note: The installation process will normally complete and display
this message within 25 minutes. However, if the expansion rack primary
power supply (PPS) firmware level is lower than that of the existing
rack(s), the installation process will automatically update the expansion
rack PPS firmware. This process will add up to one hour and 20 minutes (1:20) to the installation.
During a PPS firmware update, abnormal PPS LED status codes are expected.
Do not reboot the HMC or recycle PPS power during this update. Allow
the update to complete, and wait for the installation complete message.