| BE80CB00 |
Recovery error, soft device bus error recovered
by the IOA. |
| BE80CB01 |
Recovery error, device bus fabric error. |
| BE80CB04 |
Recovery error, the IOA recovered the logical
block LRC error on the host to IOA transfer. |
| BE80CB05 |
Recovery error, the IOA recovered the count
key data transfer LRC error on the host to IOA transfer. |
| BE80CB06 |
Recovery error, the IOA recovered the logical
block sequence number error on the host to IOA transfer. |
| BE80CB07 |
Recovery error, the IOA recovered the IOADL
tag/sequence number error. |
| BE80CB08 |
Recovery error, the IOA recovered the logical
block CRC error on the IOA to host transfer. |
| BE80CB09 |
Recovery error, the IOA recovered the logical
block sequence number error on the IOA to host transfer. |
| BE80CB0A |
Recovery error, the IOA recovered from a logical
block reference tag error. |
| BE80CB0B |
Recovery error, the IOA recovered from a logical
block guard error. |
| BE80CB0E |
Recovery error, IOA sector reassignment successful. |
| BE80CB11 |
Recovery error, the IOA recovered the soft PCI
bus error. |
| BE80CB12 |
Recovery error, the IOA recovered the device
hardware error. |
| BE80CB13 |
Recovery error, the device recovered the device
hardware error. |
| BE80CB14 |
Recovery error, the IOA recovered the soft IOA
error. |
| BE80CB15 |
Recovery error, the IOA recovered the undefined
device response. |
| BE80CB17 |
Recovery error, failure prediction threshold
exceeded. |
| BE80CB1A |
IOA not ready, IOA requested reset. |
| BE80CB1C |
Media error, data unreadable, recommend reassignment. |
| BE80CB1F |
Hardware error, IOA cannot communicate with
device. |
| BE80CB20 |
Hardware error, device bus error or device error. |
| BE80CB21 |
Hardware error, the device or IOA command has
timed out. |
| BE80CB22 |
Hardware error, device bus fabric error. |
| BE80CB29 |
Hardware error, logical block CRC error on IOA
to host transfer. |
| BE80CB2B |
Hardware error, logical block reference tag
error detected by the IOA. |
| BE80CB2C |
Hardware error, logical block guard error detected
by the IOA. |
| BE80CB2D |
Hardware error, IOA reserved area data check. |
| BE80CB2E |
Hardware error, the IOA reserved area has an
invalid data pattern. |
| BE80CB2F |
Hardware error, the IOA reserved area has T10
DIF error. |
| BE80CB30 |
Hardware error, reassignment space exceeded. |
| BE80CB31 |
Hardware error, data transfer is out of minimum
length. |
| BE80CB32 |
Hardware error, data transfer is out of maximum
length. |
| BE80CB34 |
Hardware error, device error. |
| BE80CB35 |
Hardware error, IOA Error. |
| BE80CB36 |
Hardware error, undefined device response. |
| BE80CB37 |
Hardware error, IOA microcode error. |
| BE80CB38 |
Hardware error, the IOA must be reset to recover
from an error. |
| BE80CB3A |
Hardware error, previously missing or failed
device detected but has been significantly altered. |
| BE80CB3B |
Hardware error, encountered a data check on
a read or write performed to a sector just after that sector was reassigned. |
| BE80CB3C |
Hardware error, encountered a T10 DIF error
on read to a sector just after that sector was written. |
| BE80CB3D |
Hardware error, SAS command or task management
function failed. |
| BE80CB3E |
Hardware error, different (incompatible) device
detected at resource address of previously failed device. The new
device cannot be utilized. |
| BE80CB3F |
Hardware error, invalid multi-adapter configuration. |
| BE80CB40 |
Hardware configuration error, incorrect connection
between cascaded enclosures. |
| BE80CB41 |
Hardware configuration error, connections exceed
IOA design limits. |
| BE80CB42 |
Hardware configuration error, incorrect multipath
connection. |
| BE80CB43 |
Hardware error, unsupported enclosure function. |
| BE80CB45 |
Hardware error, command to logical unit failed. |
| BE80CB48 |
Hardware error, device error, security threshold
exceeded. |
| BE80CB49 |
Hardware error, IOA error, the encryption password
is not correct. |
| BE80CB4A |
Unit Attention, rebuild of replaced/repaired
device automatically restarted. |
| BE80CB4D |
Unit Attention, device bus was reset, expander
may be at fault. |
| BE80CB50 |
Unit Attention, performance degradation, device
bus running at slower than expected speed. |
| BE80CB55 |
Unit Attention, asymmetric advanced function
DASD configuration. |
| BE80CB56 |
Unit Attention, configuration error, incomplete
multipath connection between IOA and enclosure. |
| BE80CB57 |
Unit Attention, configuration error, incomplete
multipath connection between enclosures and device. |
| BE80CB58 |
Unit Attention, configuration error, incomplete
multipath connection between IOA and remote IOA. |
| BE80CB5A |
Unit Attention, enclosure does not support a
required multipath function (OEM unit). |
| BE80CB5F |
Unit Attention, data loss on logical unit. |
| BE80CB62 |
Unit attention, corrupt array parity detected,
parity was not resynchronized. |
| BE80CB63 |
Unit Attention, array exposed, rebuilding will
start soon if there is an available spare. |
| BE80CB66 |
Unit attention, array exposed but still protected. |
| BE80CB69 |
Unit Attention, Multipath redundancy level is
incorrect. |
| BE80CB70 |
Data Protect, two or more devices are missing
in this array, and only one device is present. |
| BE80CB71 |
Data Protect, two or more devices are missing
in this array, and two or more devices are present. |
| BE80CB72 |
Data Protect, exposed array is short a required
device. |
| BE80CB73 |
Data Protect, one or more disk array members
are not at required physical locations. |
| BE80CB74 |
Data Protect, physical location of the disk
array members conflict with another disk array. |
| BE80CB75 |
Data Protect, previously degraded disk in the
disk array not found at required physical location. |
| BE80CB76 |
Data Protect, array is missing a device and
parity is out of synchronization. |
| BE80CB77 |
Data Protect, maximum number of arrays already
exist. |
| BE80CB7A |
Data Protect, IOA is out of free device identifiers. |
| BE80CB7C |
Data Protect, creation of an exposed mode device
for an array would cause IOA to exceed the maximum number of devices. |
| BE80CB7D |
Data Protect, missing an array out of a volume
set, the volume set is not functional. |
| BE80CB80 |
Data Protect, maximum number of volume sets
already exist. |
| BE80CB82 |
SIS adapter unit check data error. |
| BE80CB83 |
SIS adapter reset timeout. |
| BE80CBBD |
Unit Attention reported due to a storage enclosure RAID controller operating
at a high temperature for a prolonged duration. |