| BE190001 |
RPC-1 standby 3.3V limiter failure for CEC enclosure 1. |
| BE190002 |
RPC-2 standby 3.3V limiter failure for CEC enclosure 1. |
| BE190003 |
RPC-1 standby 3.3V limiter failure for CEC enclosure 2. |
| BE190004 |
RPC-2 standby 3.3V limiter failure for CEC enclosure 2. |
| BE190005 |
RPC-1 is held fenced by RPC-2. |
| BE190006 |
RPC-1 to RPC-2 communication failure. |
| BE190007 |
RPC-2 is held fenced by RPC-1. |
| BE190008 |
RPC-2 to RPC-1 communication failure. |
| BE190009 |
RPC-1 to CEC enclosure 1
communication failure. |
| BE19000A |
RPC-1 to CEC enclosure 2
communication failure. |
| BE19000B |
RPC-2 to CEC enclosure 1
communication failure. |
| BE19000C |
RPC-2 to CEC enclosure 2
communication failure. |
| BE190010 |
CEC enclosure 1 failed to
communicate with RPC-1 and RPC-2. |
| BE190011 |
CEC enclosure 2 failed to
communicate with RPC-1 and RPC-2. |
| BE190012 |
CEC enclosure 1 and 2 failed to
communicate with RPC-1. |
| BE190013 |
CEC enclosure 1 and 2 failed to
communicate with RPC-2. |
| BE190014 |
CEC enclosure 1 failed to
communicate with RPC-1. |
| BE190015 |
CEC enclosure 2 failed to
communicate with RPC-1. |
| BE190016 |
CEC enclosure 1 failed to
communicate with RPC-2. |
| BE190017 |
CEC enclosure 2 failed to
communicate with RPC-2. |
| BE190020 |
RPC-1 interrupt state incorrect. |
| BE190021 |
RPC-2 interrupt state incorrect. |
| BE190030 |
RPC-1 to RPC-2 communication failure. |
| BE190031 |
RPC-1 and RPC-2 failed to communicate with the rack ID logic card. |
| BE190032 |
RPC-1 failed to communicate with the rack ID logic card. |
| BE190033 |
RPC-2 failed to communicate with the rack ID logic card. |
| BE190034 |
RPC-1 and RPC-2, rack ID data CRC check. |
| BE190035 |
RPC-2, rack ID data CRC check. |
| BE190036 |
RPC-1, rack ID data CRC check. |
| BE190037 |
RPC-1, pack data parity error in flash. |
| BE190038 |
RPC-2, pack data parity error in flash. |
| BE190039 |
Remote force power-off switch is only active on RPC-1. |
| BE19003A |
Remote force power-off switch is only active on RPC-2. |
| BE19003B |
Interrupt source register failure. |
| BE19003C |
RPC-1, PPS-2 interrupt source register failure. |
| BE19003D |
RPC-2, PPS-1 interrupt source register failure. |
| BE19003E |
RPC-2, PPS-2 interrupt source register failure. |
| BE19003F |
RPC-1 indicates that RPC-2 is failing. |
| BE190040 |
RPC-2 indicates that RPC-1 is failing. |
| BE190041 |
RPC-1 failure caused CEC enclosure
1 communication failure. |
| BE190042 |
RPC-1 failure caused CEC enclosure
2 communication failure. |
| BE190043 |
RPC-2 failure caused CEC enclosure
1 communication failure. |
| BE190044 |
RPC-2 failure caused CEC enclosure
2 communication failure. |
| BE190045 |
CEC enclosure 1 standby 3.3V
source failure. |
| BE190046 |
CEC enclosure 2 standby 3.3V
source failure. |
| BE190047 |
RPC-1 remote force power-off switch source has failed. |
| BE190048 |
RPC-2 remote force power-off switch source has failed. |
| BE190049 |
RPC-1, microcode interrupt is active unexpectedly. |
| BE19004A |
RPC-2, microcode interrupt is active unexpectedly. |
| BE19004B |
Single-SFI loss of master detected with RPC-1 in fenced state. |
| BE19004C |
Single-SFI loss of master detected with RPC-2 in fenced state. |
| BE190050 |
CEC enclosure 1 failed to communicate with RPC-1 and RPC-2 through serial
paths. |
| BE190051 |
CEC enclosure 2 failed to communicate with RPC-1 and RPC-2 through serial
paths. |
| BE190052 |
CEC enclosure 1 and 2 failed to communicate with RPC-1 through serial
paths. |
| BE190053 |
CEC enclosure 1 and 2 failed to communicate with RPC-2 through serial
paths. |
| BE190054 |
CEC enclosure 1 failed to communicate with RPC-1 through serial path. |
| BE190055 |
CEC enclosure 2 failed to communicate with RPC-1 through serial path. |
| BE190056 |
CEC enclosure 1 failed to communicate with RPC-2 through serial path. |
| BE190057 |
CEC enclosure 2 failed to communicate with RPC-2 through serial path. |
| BE190058 |
CEC enclosure 1 failed to communicate with RPC-1 through serial path. |
| BE190059 |
CEC enclosure 2 failed to communicate with RPC-1 through serial path. |
| BE19005A |
CEC enclosure 1 failed to communicate with RPC-2 through serial path. |
| BE19005B |
CEC enclosure 2 failed to communicate with RPC-2 through serial path. |
| BE19005C |
CEC enclosure RS-485 serial interface card diagnostic failure during card
power on. |
| BE19011x |
RPC-1 and RPC-2 to PPS-1, rack x communication failure. |
| BE19012x |
RPC-1 and RPC-2 to PPS-2, rack x communication failure. |
| BE19013x |
RPC-1 to PPS-1, rack x communication failure. |
| BE19014x |
RPC-1 to PPS-2, rack x communication failure. |
| BE19015x |
RPC-2 to PPS-1, rack x communication failure. |
| BE19016x |
RPC-2 to PPS-2, rack x communication failure. |
| BE19017x |
RPC-1 to PPS-1 and PPS-2, rack x communication failure. |
| BE19018x |
RPC-2 to PPS-1 and PPS-2, rack x communication failure. |
| BE19021x |
RPC-1 and RPC-2 to PPS-1, rack x communication failure during PPS
configuration |
| BE19022x |
RPC-1 and RPC-2 to PPS-2, rack x communication failure during PPS
configuration |
| BE19030A |
RPC-1 local power control mode conflict. |
| BE19030B |
RPC-1 remote power control mode conflict. |
| BE19030C |
RPC-2 local power control mode conflict. |
| BE19030D |
RPC-2 remote power control mode conflict. |
| BE19100x |
Rack x, loss of line cord ac. |
| BE19101x |
PPS-1 to PPS-2, rack x communication failure. |
| BE19104x |
PPS-1 and PPS-2, rack x over current at DDM +5 volt boundary A. |
| BE19105x |
PPS-1 and PPS-2, rack x over current at DDM +12 volt boundary A. |
| BE19106x |
PPS-1 and PPS-2, rack x over current at DDM +5 volt boundary B. |
| BE19107x |
PPS-1 and PPS-2, rack x over current at DDM +12 volt boundary B. |
| BE19108x |
PPS-1 and PPS-2, rack x over current at optional DDM +5 volt boundary
A. |
| BE19109x |
PPS-1 and PPS-2, rack x over current at optional DDM +12 volt boundary
A. |
| BE1910Ax |
PPS-1 and PPS-2, rack x over current at optional DDM +5 volt boundary
B. |
| BE1910Bx |
PPS-1 and PPS-2, rack x over current at optional DDM +12 volt boundary
B. |
| BE1910Cx |
PPS-1 and PPS-2, rack x standby converter off. |
| BE1910Dx |
PPS-1 and PPS-2, rack x protected 0 +208 VDC is off. |
| BE1910Ex |
PPS-1 and PPS-2, rack x protected 1 +208 VDC is off. |
| BE1910Fx |
PPS-1 and PPS-2, rack x rack ID card communication failure. |
| BE19110x |
PPS-1, rack x loss of line cord ac. |
| BE19111x |
PPS-2, rack x loss of line cord ac. |
| BE19112x |
PPS-1, rack x line cord ac is single phase. |
| BE19113x |
PPS-2, rack x line cord ac is single phase. |
| BE19114x |
PPS-1, rack x input circuit breaker is off. |
| BE19115x |
PPS-2, rack x input circuit breaker is off. |
| BE19116x |
PPS-1, rack x UEPO switch is active. |
| BE19117x |
PPS-2, rack x UEPO switch is active. |
| BE19118x |
PPS-1, rack x UEPO converter failure. |
| BE19119x |
PPS-2, rack x UEPO converter failure. |
| BE1911Ax |
PPS-1, rack x PFC converter failure. |
| BE1911Bx |
PPS-2, rack x PFC converter failure. |
| BE1911Cx |
PPS-1, rack x internal failure. |
| BE1911Dx |
PPS-2, rack x internal failure. |
| BE1911Ex |
PPS-1, rack x power-on self-test failed. |
| BE1911Fx |
PPS-2, rack x power-on self-test failed. |
| BE19120x |
PPS-1, rack x standby converter failure. |
| BE19121x |
PPS-2, rack x standby converter failure. |
| BE19122x |
PPS-1, rack x sequencer EEPROM failure. |
| BE19123x |
PPS-2, rack x sequencer EEPROM failure. |
| BE19124x |
PPS-1, rack x sequencer heartbeat failure. |
| BE19125x |
PPS-2, rack x sequencer heartbeat failure. |
| BE19126x |
PPS-1, rack x age of BBUs differ by more than 2 years. |
| BE19127x |
PPS-2, rack x age of BBUs differ by more than 2 years. |
| BE19128x |
PPS-1, rack x fan 1 failure. |
| BE19129x |
PPS-2, rack x fan 1 failure. |
| BE1912Ax |
PPS-1, rack x fan 2 failure. |
| BE1912Bx |
PPS-2, rack x fan 2 failure. |
| BE1912Cx |
PPS-1, rack x fan 3 failure. |
| BE1912Dx |
PPS-2, rack x fan 3 failure. |
| BE1912Ex |
PPS-1, rack x over temperature at main 208V. |
| BE1912Fx |
PPS-2, rack x over temperature at main 208V. |
| BE19130x |
PPS-1, rack x over temperature at PFC. |
| BE19131x |
PPS-2, rack x over temperature at PFC. |
| BE19132x |
PPS-1, rack x over temperature at main DDM module, bus A. |
| BE19133x |
PPS-2, rack x over temperature at main DDM module, bus A. |
| BE19134x |
PPS-1, rack x over temperature at main DDM module, bus B. |
| BE19135x |
PPS-2, rack x over temperature at main DDM module, bus B. |
| BE19136x |
PPS-1, rack x over temperature at optional +208 VDC module. |
| BE19137x |
PPS-2, rack x over temperature at optional +208 VDC module. |
| BE19138x |
PPS-1, rack x over temperature at booster module. |
| BE19139x |
PPS-2, rack x over temperature at booster module. |
| BE1913Ax |
PPS-1, rack x over temperature at optional DDM module bus A. |
| BE1913Bx |
PPS-2, rack x over temperature at optional DDM module bus A. |
| BE1913Cx |
PPS-1, rack x over temperature at optional DDM module bus B. |
| BE1913Dx |
PPS-2, rack x over temperature at optional DDM module bus B. |
| BE1913Ex |
PPS-1, rack x main +208 VDC over or under voltage. |
| BE1913Fx |
PPS-1 (in rack x) module 3 offline and PPS-2 (in rack x) module 3
offline |
| BE19140x |
PPS-1 (in rack x) module 4 offline and PPS-2 (in rack x) module 4
offline |
| BE19141x |
PPS-2, rack x main +208 VDC over or under voltage. |
| BE19142x |
PPS-1, rack x main +5 VDC boundary A over or under voltage. |
| BE19143x |
PPS-2, rack x main +5 VDC boundary A over or under voltage. |
| BE19144x |
PPS-1, rack x main +12 VDC boundary A over or under voltage. |
| BE19145x |
PPS-2, rack x main +12 VDC boundary A over or under voltage. |
| BE19146x |
PPS-1, rack x main +5 VDC boundary B over or under voltage. |
| BE19147x |
PPS-2, rack x main +5 VDC boundary B over or under voltage. |
| BE19148x |
PPS-1, rack x main +12 VDC boundary B over or under voltage. |
| BE19149x |
PPS-2, rack x main +12 VDC boundary B over or under voltage. |
| BE1914Ax |
PPS-1, rack x optional +5 VDC boundary A over or under voltage |
| BE1914Bx |
PPS-2, rack x optional +5 VDC boundary A over or under voltage. |
| BE1914Cx |
PPS-1, rack x optional +12 VDC boundary A over or under voltage. |
| BE1914Dx |
PPS-2, rack x optional +12 VDC boundary A over or under voltage. |
| BE1914Ex |
PPS-1, rack x optional +5 VDC boundary B over or under voltage. |
| BE1914Fx |
PPS-2, rack x optional +5 VDC boundary B over or under voltage. |
| BE19150x |
PPS-1, rack x optional +12 VDC boundary B over or under voltage. |
| BE19151x |
PPS-2, rack x optional +12 VDC boundary B over or under voltage. |
| BE19152x |
PPS-1, rack x optional +208 VDC over or under voltage. |
| BE19153x |
PPS-2, rack x optional +208 VDC over or under voltage. |
| BE19154x |
PPS-1, rack x optional booster module test failed. |
| BE19155x |
PPS-2, rack x optional booster module test failed. |
| BE19156x |
PPS-1, rack x main DDM +5 VDC A current sharing fault not isolated. |
| BE19157x |
PPS-2, rack x main DDM +5 VDC A current sharing fault not isolated. |
| BE19158x |
PPS-1, rack x main DDM +5 VDC B current sharing fault not isolated. |
| BE19159x |
PPS-2, rack x main DDM +5 VDC B current sharing fault not isolated. |
| BE1915Ax |
PPS-1, rack x main DDM +12 VDC A current sharing fault not isolated. |
| BE1915Bx |
PPS-2, rack x main DDM +12 VDC A current sharing fault not isolated. |
| BE1915Cx |
PPS-1, rack x main DDM +12 VDC B current sharing fault not isolated. |
| BE1915Dx |
PPS-2, rack x main DDM +12 VDC B current sharing fault not isolated. |
| BE1915Ex |
PPS-1, rack x to front fan sense card communication failure. |
| BE1915Fx |
PPS-2, rack x to rear fan sense card communication failure. |
| BE19160x |
PPS-1, rack x to front fan sense card data compare failure. |
| BE19161x |
PPS-2, rack x to rear fan sense card data compare failure. |
| BE19162x |
Rack ID card, rack x Rack_ID CRC failure. |
| BE19163x |
Rack ID card, rack x Rack_ID CRC failure. |
| BE19168x |
PPS-1, rack x internal I2C interface failure. |
| BE19169x |
PPS-2, rack x internal I2C interface failure. |
| BE1916Ax |
PPS-1, rack x internal I2C interface failure at PFC. |
| BE1916Bx |
PPS-2, rack x internal I2C interface failure at PFC. |
| BE1916Cx |
PPS-1, rack x internal I2C interface failure at +208 VDC. |
| BE1916Dx |
PPS-2, rack x internal I2C interface failure at +208 VDC. |
| BE1916Ex |
PPS-1, rack x internal I2C interface failure at main DDM. |
| BE1916Fx |
PPS-2, rack x internal I2C interface failure at main DDM. |
| BE19170x |
PPS-1, rack x internal I2C interface failure at booster module. |
| BE19171x |
PPS-2, rack x internal I2C interface failure at booster module. |
| BE19172x |
PPS-1, rack x internal I2C interface failure at optional module. |
| BE19173x |
PPS-2, rack x internal I2C interface failure at optional module. |
| BE19174x |
PPS-1, rack x over current at DDM +5 VDC boundary A. |
| BE19175x |
PPS-2, rack x over current at DDM +5 VDC boundary A. |
| BE19176x |
PPS-1, rack x over current at DDM +12 VDC boundary A. |
| BE19177x |
PPS-2, rack x over current at DDM +12 VDC boundary A. |
| BE19178x |
PPS-1, rack x over current at DDM +5 VDC boundary B. |
| BE19179x |
PPS-2, rack x over current at DDM +5 VDC boundary B. |
| BE1917Ax |
PPS-1, rack x over current at DDM +12 VDC boundary B. |
| BE1917Bx |
PPS-2, rack x over current at DDM +12 VDC boundary B. |
| BE1917Cx |
PPS-1, rack x over current at optional DDM +5 VDC boundary A. |
| BE1917Dx |
PPS-2, rack x over current at optional DDM +5 VDC boundary A. |
| BE1917Ex |
PPS-1, rack x over current at optional DDM +12 VDC boundary A. |
| BE1917Fx |
PPS-2, rack x over current at optional DDM +12 VDC boundary A. |
| BE19180x |
PPS-1, rack x over current at optional DDM +5 VDC boundary B. |
| BE19181x |
PPS-2, rack x over current at optional DDM +5 VDC boundary B. |
| BE19182x |
PPS-1, rack x over current at optional DDM +12 VDC boundary B. |
| BE19183x |
PPS-2, rack x over current at optional DDM +12 VDC boundary B. |
| BE19184x |
PPS-1, rack x over current at main and optional +208 VDC. |
| BE19185x |
PPS-2, rack x over current at main and optional +208 VDC. |
| BE19186x |
PPS-1, rack x over current at main +208 VDC with opt. +208 VDC
installed. |
| BE19187x |
PPS-2, rack x over current at main +208 VDC with opt. +208 VDC
installed. |
| BE19188x |
PPS-1, rack x over current at optional +208 VDC. |
| BE19189x |
PPS-2, rack x over current at optional +208 VDC. |
| BE1918Ax |
PPS-1, rack x over current at main +208 VDC. |
| BE1918Bx |
PPS-2, rack x over current at main +208 VDC. |
| BE1918Cx |
PPS-1, rack x main DDM power boundary A is off. |
| BE1918Dx |
PPS-2, rack x main DDM power boundary A is off. |
| BE1918Ex |
PPS-1, rack x main DDM +5 VDC power boundary A is off. |
| BE1918Fx |
PPS-2, rack x main DDM +5 VDC power boundary A is off. |
| BE19190x |
PPS-1, rack x main DDM +12 VDC power boundary A is off. |
| BE19191x |
PPS-2, rack x main DDM +12 VDC power boundary A is off. |
| BE19192x |
PPS-1, rack x main DDM power boundary B is off. |
| BE19193x |
PPS-2, rack x main DDM power boundary B is off. |
| BE19194x |
PPS-1, rack x main DDM +5 VDC power boundary B is off. |
| BE19195x |
PPS-2, rack x main DDM +5 VDC power boundary B is off. |
| BE19196x |
PPS-1, rack x main DDM +12 VDC power boundary B is off. |
| BE19197x |
PPS-2, rack x main DDM +12 VDC power boundary B is off. |
| BE19198x |
PPS-1, rack x main +208 VDC is off. |
| BE19199x |
PPS-2, rack x main +208 VDC is off. |
| BE1919Ax |
PPS-1, rack x protected 0 +208 VDC is off. |
| BE1919Bx |
PPS-2, rack x protected 0 +208 VDC is off. |
| BE1919Cx |
PPS-1, rack x protected 1 +208 VDC is off. |
| BE1919Dx |
PPS-2, rack x protected 1 +208 VDC is off. |
| BE1919Ex |
PPS-1, rack x optional DDM power boundary A is off. |
| BE1919Fx |
PPS-2, rack x optional DDM power boundary A is off. |
| BE191A0x |
PPS-1, rack x optional DDM +5 VDC power boundary A is off. |
| BE191A1x |
PPS-2, rack x optional DDM +5 VDC power boundary A is off. |
| BE191A2x |
PPS-1, rack x optional DDM +12 VDC power boundary A is off. |
| BE191A3x |
PPS-2, rack x optional DDM +12 VDC power boundary A is off. |
| BE191A4x |
PPS-1, rack x optional DDM power boundary B is off. |
| BE191A5x |
PPS-2, rack x optional DDM power boundary B is off. |
| BE191A6x |
PPS-1, rack x optional DDM +5 VDC power boundary B is off. |
| BE191A7x |
PPS-2, rack x optional DDM +5 VDC power boundary B is off. |
| BE191A8x |
PPS-1, rack x optional DDM +12 VDC power boundary B is off. |
| BE191A9x |
PPS-2, rack x optional DDM +12 VDC power boundary B is off. |
| BE191AAx |
PPS-1, rack x optional +208 VDC is off. |
| BE191ABx |
PPS-2, rack x optional +208 VDC is off. |
| BE191ACx |
PPS-1, rack x all fans failing. |
| BE191ADx |
PPS-2, rack x all fans failing. |
| BE191AEx |
PPS-1, rack x fans 1 and 2 failure. |
| BE191AFx |
PPS-2, rack x fans 1 and 2 failure. |
| BE191B0x |
PPS-1, rack x fans 1 and 3 failure. |
| BE191B1x |
PPS-2, rack x fans 1 and 3 failure. |
| BE191B2x |
PPS-1, rack x fans 2 and 3 failure. |
| BE191B3x |
PPS-2, rack x fans 2 and 3 failure. |
| BE191B4x |
PPS-1, rack x rack ID card communication failure. |
| BE191B5x |
PPS-2, rack x rack ID card communication failure. |
| BE191B6x |
Rack x, front/back mismatch between PPS-1 and RPC-1. |
| BE191B7x |
Rack x, front/back mismatch between PPS-2 and RPC-1. |
| BE191B8x |
PPS-1, rack x main DDM +5 VDC A current sharing fault. |
| BE191B9x |
PPS-2, rack x main DDM +5 VDC A current sharing fault. |
| BE191BAx |
PPS-1, rack x main DDM +5 VDC B current sharing fault. |
| BE191BBx |
PPS-2, rack x main DDM +5 VDC B current sharing fault. |
| BE191BCx |
PPS-1, rack x main DDM +12 VDC A current sharing fault. |
| BE191BDx |
PPS-2, rack x main DDM +12 VDC A current sharing fault. |
| BE191BEx |
PPS-1, rack x main DDM +12 VDC B current sharing fault. |
| BE191BFx |
PPS-2, rack x main DDM +12 VDC B current sharing fault. |
| BE191C0x |
PPS-1, rack x optional DDM +5 VDC A current sharing fault. |
| BE191C1x |
PPS-2, rack x optional DDM +5 VDC A current sharing fault. |
| BE191C2x |
PPS-1, rack x optional DDM +5 VDC B current sharing fault. |
| BE191C3x |
PPS-2, rack x optional DDM +5 VDC B current sharing fault. |
| BE191C4x |
PPS-1, rack x optional DDM +12 VDC A current sharing fault. |
| BE191C5x |
PPS-2, rack x optional DDM +12 VDC A current sharing fault. |
| BE191C6x |
PPS-1, rack x optional DDM +12 VDC B current sharing fault. |
| BE191C7x |
PPS-2, rack x optional DDM +12 VDC B current sharing fault. |
| BE191C8x |
PPS-1, rack x main +208 VDC current sharing fault, opt. +208
installed. |
| BE191C9x |
PPS-2, rack x main +208 VDC current sharing fault, opt. +208
installed. |
| BE191CAx |
PPS-1, rack x main +208 VDC current sharing fault not isolated. |
| BE191CBx |
PPS-2, rack x main +208 VDC current sharing fault not isolated. |
| BE191CCx |
PPS-1, rack x optional +208 VDC module current sharing fault. |
| BE191CDx |
PPS-2, rack x optional +208 VDC module current sharing fault. |
| BE191CEx |
Rack x, front/back mismatch between PPS-1 and RPC-2. |
| BE191CFx |
Rack x, front/back mismatch between PPS-2 and RPC-2. |
| BE191D1x |
Rack x shows on battery with line cord ac still present. |
| BE191D2x |
Rack x shows on battery with line cord ac still present. |
| BE191D4x |
RPC-1, True and Not True interrupt state set for PPS-1. |
| BE191D5x |
RPC-2, True and Not True interrupt state set for PPS-1. |
| BE191D6x |
RPC-1, True and Not True interrupt state set for PPS-2. |
| BE191D7x |
RPC-2, True and Not True interrupt state set for PPS-2. |
| BE191DAx |
PPS-1, rack x optional booster module is off. |
| BE191DBx |
PPS-2, rack x optional booster module is off. |
| BE191DCx |
PPS-1 and PPS-2, rack x RPC-1 data, pack data parity error. |
| BE191DDx |
PPS-1 and PPS-2, rack x RPC-2 data, pack data parity error. |
| BE191DEx |
PPS-1, rack x RPC-1 pack data parity error. |
| BE191DFx |
PPS-1, rack x RPC-2 pack data parity error. |
| BE191E0x |
PPS-2, rack x RPC-1 pack data parity error. |
| BE191E1x |
PPS-2, rack x RPC-2 pack data parity error. |
| BE191E2x |
PPS-1, frame x indicating battery low. |
| BE191E3x |
PPS-2, frame x indicating battery low. |
| BE191E4x |
PPS-1 and PPS-2, rack x indicating battery low. |
| BE191E5x |
PPS-1, rack x input circuit breaker is tripped. |
| BE191E6x |
PPS-2, rack x input circuit breaker is tripped. |
| BE191E7x |
PPS-1, rack x booster module failure during battery test. |
| BE191E8x |
PPS-2, rack x booster module failure during battery test. |
| BE191E9x |
PPS-1, rack x booster module failure during battery backup. |
| BE191EAx |
PPS-2, rack x booster module failure during battery backup. |
| BE191EBx |
PPS-1, rack x booster module failure while in hot standby. |
| BE191ECx |
PPS-2, rack x booster module failure while in hot standby. |
| BE191EDx |
PPS-1, rack x reported control registers are incorrect from RPC-1. |
| BE191EEx |
PPS-2, rack x reported control registers are incorrect from RPC-1. |
| BE191EFx |
PPS-1, rack x reported control registers are incorrect from RPC-2. |
| BE191F0x |
PPS-2, rack x reported control registers are incorrect from RPC-2. |
| BE191F10 |
Storage facility was automatically powered on after customer line cord power
was restored. |
| BE191F4x |
PPS-2, rack x missing battery configuration message. |
| BE191F5x |
PPS-1, rack x (x is last digit of reference code) restore of line cord
AC. |
| BE191F6x |
PPS-2, rack x (x is last digit of reference code) restore of line cord
AC. |
| BE191F7x |
PPS-1, rack x (x is last digit of reference code) restore of 3-phase line cord
AC. |
| BE191F8x |
PPS-2, rack x (x is last digit of reference code) restore of 3-phase line cord
AC. |
| BE191F9x |
PPS-1 and PPS-2, rack x missing system clock setting configuration
message. |
| BE191FAx |
PPS-1, rack x missing system clock setting configuration message. |
| BE191FBx |
PPS-1 and PPS-2, rack x missing battery configuration message. |
| BE191FCx |
PPS-1, rack x missing battery configuration message. |
| BE191FDx |
PPS-2, rack x missing system clock setting configuration message. |
| BE191FEx |
PPS-1, rack x, AC loss conflict - HW AC Off line in PPS-PPS communication
cable is open. |
| BE191FFx |
PPS-2, rack x, AC loss conflict - HW AC Off line in PPS-PPS communication
cable is open. |
| BE192001 |
One or more power system batteries are approaching end of life. |
| BE19201x |
Rack x, PPS-1 and PPS-2 to BBU1 communication failure. |
| BE19202x |
Rack x, PPS-1 and PPS-2 to BBU2 communication failure. |
| BE19203x |
Rack x, PPS-1 and PPS-2 to BBU3 communication failure. |
| BE19204x |
Rack x, PPS-1 to BBU1, BBU2 and BBU3 comm. failure. |
| BE19205x |
Rack x, PPS-2 to BBU1, BBU2 and BBU3 comm. failure. |
| BE192069 |
Power system batteries are approaching end of life. |
| BE19206A |
Power system batteries are approaching end of life, group 1. |
| BE19206B |
Power system batteries are approaching end of life, group 2. |
| BE19206C |
Power system batteries are approaching end of life, group 3. |
| BE19206x |
Rack x, PPS-1 to BBU1 communication failure. |
| BE19207x |
Rack x, PPS-1 to BBU2 communication failure. |
| BE19208x |
Rack x, PPS-1 to BBU3 communication failure. |
| BE19209x |
Rack x, PPS-2 to BBU1 communication failure. |
| BE1920Ax |
Rack x, PPS-2 to BBU2 communication failure. |
| BE1920Bx |
Rack x, PPS-2 to BBU3 communication failure. |
| BE1920Cx |
Rack x, PPS-1 and PPS-2 to BBU1 charging failure. |
| BE1920Dx |
Rack x, PPS-1 and PPS-2 to BBU2 charging failure. |
| BE1920Ex |
Rack x, PPS-1 and PPS-2 to BBU3 charging failure. |
| BE1920Fx |
Rack x, PPS-1 to BBU1, BBU2 and BBU3 charging failure. |
| BE19210x |
Rack x, PPS-2 to BBU1, BBU2 and BBU3 charging failure. |
| BE19211x |
Rack x, PPS-1 to BBU1 charging failure. |
| BE19212x |
Rack x, PPS-1 to BBU2 charging failure. |
| BE19213x |
Rack x, PPS-1 to BBU3 charging failure. |
| BE19214x |
Rack x, PPS-2 to BBU1 charging failure. |
| BE19215x |
Rack x, PPS-2 to BBU2 charging failure. |
| BE19216x |
Rack x, PPS-2 to BBU3 charging failure. |
| BE19217x |
Rack x, BBU1 battery voltage not present at output. |
| BE19218x |
Rack x, BBU2 battery voltage not present at output. |
| BE19219x |
Rack x, BBU3 battery voltage not present at output. |
| BE1921Ax |
Rack x, BBU1 fan failure. |
| BE1921Bx |
Rack x, BBU2 fan failure. |
| BE1921Cx |
Rack x, BBU3 fan failure. |
| BE1921Dx |
Rack x, BBU1 temperature sensor failure. |
| BE1921Ex |
Rack x, BBU2 temperature sensor failure. |
| BE1921Fx |
Rack x, BBU3 temperature sensor failure. |
| BE19220x |
Rack x, BBU1 under voltage. |
| BE19221x |
Rack x, BBU2 under voltage. |
| BE19222x |
Rack x, BBU3 under voltage. |
| BE19223x |
Rack x, BBU1 O-ring diode shorted. |
| BE19224x |
Rack x, BBU2 O-ring diode shorted. |
| BE19225x |
Rack x, BBU3 O-ring diode shorted. |
| BE19226x |
Rack x, BBU1 not connected to +208 VDC bus A. |
| BE19227x |
Rack x, BBU2 not connected to +208 VDC bus A. |
| BE19228x |
Rack x, BBU3 not connected to +208 VDC bus A. |
| BE19229x |
Rack x, BBU1 not connected to +208 VDC bus B. |
| BE1922Ax |
Rack x, BBU2 not connected to +208 VDC bus B. |
| BE1922Bx |
Rack x, BBU3 not connected to +208 VDC bus B. |
| BE1922Cx |
Rack x, BBU1 discharge current check. |
| BE1922Dx |
Rack x, BBU2 discharge current check. |
| BE1922Ex |
Rack x, BBU3 discharge current check. |
| BE1922Fx |
Rack x, BBU1 cannot be charged. |
| BE19230x |
Rack x, BBU2 cannot be charged. |
| BE19231x |
Rack x, BBU3 cannot be charged. |
| BE19232x |
Rack x, BBU1 EEPROM failure. |
| BE19233x |
Rack x, BBU2 EEPROM failure. |
| BE19234x |
Rack x, BBU3 EEPROM failure. |
| BE19235x |
Rack x, BBU1 BSM EEPROM failure. |
| BE19236x |
Rack x, BBU2 BSM EEPROM failure. |
| BE19237x |
Rack x, BBU3 BSM EEPROM failure. |
| BE19238x |
Rack x, BBU1 more than 8 months since last charge. |
| BE19239x |
Rack x, BBU2 more than 8 months since last charge. |
| BE1923Ax |
Rack x, BBU3 more than 8 months since last charge. |
| BE1923Bx |
Rack x, BBU1 voltage sensor failure. |
| BE1923Cx |
Rack x, BBU2 voltage sensor failure. |
| BE1923Dx |
Rack x, BBU3 voltage sensor failure. |
| BE1923Ex |
Rack x, PPS-1 and PPS-2 to BBU2 communication failure. |
| BE1923Fx |
Rack x, PPS-1 and PPS-2 to BBU3 communication failure. |
| BE19240x |
Rack x, PPS-1 to BBU2 and BBU3 communication failure. |
| BE19241x |
Rack x, PPS-2 to BBU2 and BBU3 communication failure. |
| BE19242x |
Rack x, Multiple BBUs with voltage not present at output. |
| BE19243x |
Rack x, PPS-1 voltage sensor failure. |
| BE19244x |
Rack x, PPS-2 voltage sensor failure. |
| BE19245x |
Rack x, Multiple BBUs under voltage. |
| BE19248x |
Rack x, PPS-1 to BBU2 and BBU3 charging failure. |
| BE19249x |
Rack x, PPS-2 to BBU2 and BBU3 charging failure. |
| BE1924Ax |
Rack x, BBU1 failed connection test and discharge current check. |
| BE1924Bx |
Rack x, BBU2 failed connection test and discharge current check. |
| BE1924Cx |
Rack x, BBU3 failed connection test and discharge current check. |
| BE192500 |
RPC fault not isolated, but RPC in fenced state. |
| BE19251x |
Rack x, PPS fault not isolated, but PPS in fenced state. |
| BE192560 |
PBCM RPC register corruption with fenced RPC. |
| BE192561 |
PBCM RPC register corruption without fenced RPC. |
| BE192562 |
PPCL RPC register corruption with fenced RPC. |
| BE192563 |
PPCL RPC register corruption without fenced RPC. |
| BE192564 |
FDCL RPC register corruption with fenced RPC. |
| BE192565 |
FDCL RPC register corruption without fenced RPC. |
| BE192566 |
ISR RPC register corruption with fenced RPC |
| BE192567 |
ISR RPC register corruption without fenced RPC |
| BE19252x |
Rack x, BBU fault not isolated, but BBU in fenced state. |
| BE193000 |
HMC Power controlling firmware microcode logic error |
| BE193001 |
Rack 1, HMC to RPC connection failure. Check all cables, reboot HMC, and
retry. |
| BE193002 |
HMC power controlling firmware MLE. Missing/bad pack ID files on HMC. |
| BE193003 |
The RPC/PPS firmware file is missing on the HMC |
| BE193011 |
Rack 1, close SRC BE193001: HMC to RPC connection failure. |
| BE193012 |
Rack 1, the RPC card flash update/read operation failed. |
| BE193080 |
Service Processor function's power controlling firmware microcode
logic error |
| BE1930F0 |
The number of batteries found does not match what is expected. Check
configuration. |
| BE1930F1 |
Rack x, expected rack MTMS does not match content in primary PPS-1. Check
configuration. |
| BE193100 |
Rack 1, RPC-1 not communicating with either service processor
function. |
| BE193101 |
Rack x, RPC-1 not communicating with either PPS. |
| BE193102 |
Rack 1, expected zSeries setting in RPC-1 is not correct. |
| BE193103 |
The firmware update to RPC-1 failed. |
| BE193104 |
RPC-2 card SF power state is "Off", continuing CDA process for RPC-1
card will cause SF to power off. |
| BE193105 |
RPC-2 failed to power on. |
| BE193106 |
RPC-1 card SF power control mode failed to change. |
| BE193110 |
RPC-1 remote power and RPC-2 local power mode conflict. |
| BE193111 |
RPC-1 local power and RPC-2 remote power mode conflict. |
| BE193150 |
Rack x, the RPC-1 and RPC-2 communication cables are swapped in PPS. |
| BE193300 |
Rack x, both RPCs not communicating with either PPS. |
| BE193301 |
Rack x, RPC-1 not communicating with either PPS. |
| BE193302 |
Rack 1, expected zSeries setting in RPC-2 is not correct. |
| BE193303 |
The firmware update to RPC-2 failed. |
| BE193306 |
RPC-2 card SF power control mode failed to change. |
| BE19350x |
Rack x, unable to read/write the rack MTMS to primary PPS-1. |
| BE19351x |
Rack x, RPC-1 unable to communicate with PPS-1. |
| BE19352x |
Rack x, RPC-2 unable to communicate with PPS-1. |
| BE19353x |
Rack x PPS-1 unable to communicate with either RPC. |
| BE19354x |
Rack x PPS's module count are not equal; the module count in PPS-1 does not
match PPS-2. |
| BE19355x |
Rack x PPS-1 is unable to obtain battery VPD data. |
| BE19356x |
Rack x PPS's contain the PLD module, while the base rack PPS's do not. |
| BE19357x |
Rack x PPS's do not contain the PLD module. while the base rack PPS's
do. |
| BE19358x |
PPS-1, rack x main +208 VDC is off |
| BE19359x |
PPS-2, rack x main +208 VDC is off |
| BE193600 |
The firmware update to PPS-1 failed. |
| BE193601 |
PPS firmware update failed; RPC-1 did not clear PBCM download
registers. |
| BE193602 |
PPS-1 failed to go into firmware download mode. |
| BE193603 |
The firmware S-record data transfer to PPS-1 failed. |
| BE19370x |
Rack x, unable to write the rack MTMS to PPS-2. |
| BE19371x |
Rack x, RPC-1 unable to communicate with PPS-2. |
| BE19372x |
Rack x, RPC-2 unable to communicate with PPS-2. |
| BE19373x |
Rack x PPS-2 unable to communicate with either RPC. |
| BE19374x |
Rack x - missing, broken, or powered off PLD module in Primary PPS. |
| BE19375x |
Rack x - missing, broken, or powered off Optional DDM module in Primary
PPS. |
| BE193800 |
The firmware update to PPS-2 failed. |
| BE193802 |
PPS-2 failed to go into firmware download mode. |
| BE193803 |
The firmware S-record data transfer to PPS-2 failed. |
| BE193804 |
Loss of input power to multiple CECs and/or I/O enclosures -> possibly bus bar
loose cables or failure. |
| BE193805 |
Loss of input power to multiple CECs and/or IO Enclosures ->
Possibly 'Bus Bar group A' loose cable(s) OR failure. |
| BE193806 |
Loss of input power to multiple CECs and/or IO Enclosures ->
Possibly 'Bus Bar group B' loose cable(s) OR failure. |
| BE19381x |
Rack x (x is last digit of reference code), loss of input power from upper
DC-UPS to multiple CECs, I/O enclosures, or both. |
| BE19382x |
Rack x (x is last digit of reference code), loss of input power from lower
DC-UPS to multiple CECs, I/O enclosures, or both. |
| BE19383x |
Rack x (x is last digit of reference code), loss of input power from lower
DC-UPS to multiple CECs, I/O enclosures, or both. |
| BE19384x |
Rack x (x is last digit of reference code), loss of input power from upper
DC-UPS to multiple CECs, I/O enclosures, or both. |
| BE19385x |
Rack x (x is last digit of reference code), loss of input power from upper
DC-UPS to multiple CECs, I/O enclosures, or both. |
| BE19386x |
Rack x (x is last digit of reference code), loss of input power from lower
DC-UPS to multiple CECs, I/O enclosures, or both. |
| BE193900 |
A power resource failed to Reset Service Mode and is unavailable. |
| BE19390x |
Rack x battery or batteries is/are being reported as disconnected. |
| BE19391x |
Rack x PPS is reporting missing Line cord ac tripped CB, or no 3 phase
power. |
| BE19392x |
Rack x MES failure, a PPS or BBU resource in this rack is reporting a
fault. |
| BE19393x |
Rack x Battery failure, a BBU resource in this rack is reporting a
fault. |
| BE19394x |
Rack x Battery charging, a BBU resource in this rack is still
charging. |
| BE19395x |
Rack x PPS-1 may have invalid PPS ID = 1. Communication to RPC is
down. |
| BE19396x |
Rack x was last powered down using the Red ( UEPO ) Switch. |
| BE19397x |
One or more rack x batteries are not present during IML. |
| BE19400x |
PPS-1, rack x DDM signal failure at both fan sense cards. |
| BE19401x |
PPS-2, rack x DDM signal failure at both fan sense cards. |
| BE19402x |
PPS-1, rack x DDM signal failure at front fan sense card. |
| BE19403x |
PPS-1, rack x DDM signal failure at rear fan sense card. |
| BE19404x |
PPS-2, rack x DDM signal failure at rear fan sense card. |
| BE19405x |
PPS-2, rack x DDM signal failure at front fan sense card. |
| BE19406x |
PPS-1 and PPS-2, rack x temperature alert. |
| BE19407x |
PPS-2, rack x invalid high fan speed setting from PPS-1. |
| BE19408x |
PPS-1, rack x invalid high fan speed setting from PPS-2. |
| BE19409x |
PPS-2, rack x invalid low fan speed setting from PPS-1. |
| BE1940Ax |
PPS-1, rack x invalid low fan speed setting from PPS-2. |
| BE1940Cx |
PPS-1, rack x DASD fan tray assembly 2 I2C interface failure. |
| BE1940Dx |
PPS-2, rack x DASD fan tray assembly 3 I2C interface failure. |
| BE1940Ex |
PPS-1, rack x DASD fan tray assembly 1 I2C interface failure. |
| BE19410x |
PPS-1, rack x fan failure in DASD fan tray assembly 2. |
| BE19411x |
PPS-2, rack x fan failure in DASD fan tray assembly 3. |
| BE19412x |
PPS-1, rack x fan failure in DASD fan tray assembly 1. |
| BE19414x |
PPS-1, rack x invalid fan speed setting from rear fan sense card. |
| BE19415x |
PPS-2, rack x invalid fan speed setting from front fan sense card. |
| BE19416x |
PPS-1, rack x temperature alert. |
| BE19417x |
PPS-2, rack x temperature alert. |
| BE19418x |
PPS-1, rack x front fan sense card EEPROM failure. |
| BE19419x |
PPS-1, rack x rear fan sense card EEPROM failure. |
| BE19500x |
PPS-1, rack x main +208 VDC voltage sensor failure. |
| BE19501x |
PPS-2, rack x main +208 VDC voltage sensor failure. |
| BE19502x |
PPS-1, rack x main +208 VDC current sensor failure. |
| BE19503x |
PPS-2, rack x main +208 VDC current sensor failure. |
| BE19504x |
PPS-1, rack x optional +208 VDC voltage sensor failure. |
| BE19505x |
PPS-2, rack x optional +208 VDC voltage sensor failure. |
| BE19506x |
PPS-1, rack x optional +208 VDC voltage current failure. |
| BE19507x |
PPS-2, rack x optional +208 VDC voltage current failure. |
| BE19508x |
PPS-1, rack x main +5 VDC boundary A voltage sensor failure. |
| BE19509x |
PPS-2, rack x main +5 VDC boundary A voltage sensor failure. |
| BE1950Ax |
PPS-1, rack x main +5 VDC boundary A current sensor failure. |
| BE1950Bx |
PPS-2, rack x main +5 VDC boundary A current sensor failure. |
| BE1950Cx |
PPS-1, rack x main +5 VDC boundary B voltage sensor failure. |
| BE1950Dx |
PPS-2, rack x main +5 VDC boundary B voltage sensor failure. |
| BE1950Ex |
PPS-1, rack x main +5 VDC boundary B current sensor failure. |
| BE1950Fx |
PPS-2, rack x main +5 VDC boundary B current sensor failure. |
| BE19510x |
PPS-1, rack x optional +5 VDC boundary A voltage sensor failure. |
| BE19511x |
PPS-2, rack x optional +5 VDC boundary A voltage sensor failure. |
| BE19512x |
PPS-1, rack x optional +5 VDC boundary A current sensor failure. |
| BE19513x |
PPS-1, rack x optional +5 VDC boundary A current sensor failure. |
| BE19514x |
PPS-1, rack x optional +5 VDC boundary B voltage sensor failure. |
| BE19515x |
PPS-2, rack x optional +5 VDC boundary B voltage sensor failure. |
| BE19516x |
PPS-1, rack x optional +5 VDC boundary B current sensor failure. |
| BE19517x |
PPS-2, rack x optional +5 VDC boundary B current sensor failure. |
| BE19518x |
PPS-1, rack x main +12 VDC boundary A voltage sensor failure. |
| BE19519x |
PPS-2, rack x main +12 VDC boundary A voltage sensor failure. |
| BE1951Ax |
PPS-1, rack x main +12 VDC boundary A current sensor failure. |
| BE1951Bx |
PPS-2, rack x main +12 VDC boundary A current sensor failure. |
| BE1951Cx |
PPS-1, rack x main +12 VDC boundary B voltage sensor failure. |
| BE1951Dx |
PPS-2, rack x main +12 VDC boundary B voltage sensor failure. |
| BE1951Ex |
PPS-1, rack x main +12 VDC boundary B current sensor failure. |
| BE1951Fx |
PPS-2, rack x main +12 VDC boundary B current sensor failure. |
| BE19520x |
PPS-1, rack x optional +12 VDC boundary A voltage sensor failure. |
| BE19521x |
PPS-2, rack x optional +12 VDC boundary A voltage sensor failure. |
| BE19522x |
PPS-1, rack x optional +12 VDC boundary A current sensor failure. |
| BE19523x |
PPS-2, rack x optional DDM +12 VDC boundary A current sensor failure. |
| BE19524x |
PPS-1, rack x optional +12 VDC boundary B voltage sensor failure. |
| BE19525x |
PPS-2, rack x optional +12 VDC boundary B voltage sensor failure. |
| BE19526x |
PPS-1, rack x optional +12 VDC boundary B current sensor failure. |
| BE19527x |
PPS-2, rack x optional +12 VDC boundary B current sensor failure. |
| BE19528x |
PPS-1, rack x booster module sensor failure. |
| BE19529x |
PPS-2, rack x booster module sensor failure. |
| BE1952Ax |
Rack ID data cannot be read in rack x; Rack Identify LED is in use. |
| BE1952Bx |
Both PPSs detected EPOW or Power Good signal failure on partner in rack
x. |
| BE1952Cx |
PPS-1 main 208V offline and PPS-2 module 3 offline and PPS-2 module 4 offline
in rack x (x is last digit of reference code). |
| BE1952Dx |
PPS-2 main 208V offline and PPS-1 module 3 offline and PPS-1 module 4 offline
in rack x (x is last digit of reference code). |
| BE1952Dx |
PPS-2 main 208V offline and PPS-1 module 3 offline and PPS-1 module 4 offline
in rack x (x is last digit of reference code). |
| BE1952Ex |
Both PPSs reporting partner EPOW mismatch in rack x (x is last digit of
reference code). |
| BE196010 |
One CEC enclosure failed to communicate with both RPC cards. |
| BE196012 |
One RPC card failed to communicate with multiple CEC enclosures. |
| BE19700x |
RPC-1 and RPC-2 are both failing to communicate with DC-UPS in rack x (x is
last digit of reference code). |
| BE19702x |
RPC is failing to communicate with DC-UPS-1 and DC-UPS-2 in rack x (x is last
digit of reference code). |
| BE19704x |
RPC-1 is failing to communicate with DC-UPS-1 in rack x (x is last digit of
reference code). |
| BE19705x |
RPC-2 is failing to communicate with DC-UPS-1 in rack x (x is last digit of
reference code). |
| BE19706x |
RPC-1 is failing to communicate with DC-UPS-2 in rack x (x
is last digit of reference code). |
| BE19707x |
RPC-2 is failing to communicate with DC-UPS-2 in rack x (x is last digit of
reference code). |
| BE19B01x |
Rack x (x is last digit of reference code), DC-UPS power output not complete:
One or more output boundaries are not turned on. |
| BE19B02x |
Rack x (x is last digit of reference code), low battery. |
| BE19B04x |
Rack x (x is last digit of reference code), DC-UPS on battery. |
| BE19B06x |
Rack x (x is last digit of reference code), Control Registers from RPC-2
differ from RPC-1 and indicate off or disabled. |
| BE19B08x |
Rack x (x is last digit of reference code), Control Registers from RPC-1
differ from RPC-2 and indicate off or disabled. |
| BE19B0Bx |
Rack x (x is last digit of reference code), Both DC-UPSs report a
communication failure to RPC. |
| BE19B0Dx |
Rack x (x is last digit of reference code), DC-UPS reports communication
failures to both RPCs. |
| BE19B11x |
Rack x (x is last digit of reference code), DC-UPS has not received the system
EPLD configuration message. |
| BE19B13x |
Rack x (x is last digit of reference code), DC-UPS local ac input not
present. |
| BE19B15x |
Rack x (x is last digit of reference code), DC-UPS input circuit breaker is
not on. |
| BE19B16x |
Rack x (x is last digit of reference code), DC-UPS missing single input ac
phase. |
| BE19B19x |
Rack x (x is last digit of reference code), DC-UPS UEPO Converter not
on. |
| BE19B1Bx |
Rack x (x is last digit of reference code), DC-UPS UEPO Contactor not
on. |
| BE19B1Dx |
Rack x (x is last digit of reference code), DC-UPS partner phase 3 ac is not
present. |
| BE19B1Fx |
Rack x (x is last digit of reference code), DC-UPS partner phase 2 ac is not
present. |
| BE19B21x |
Rack x (x is last digit of reference code), DC-UPS partner phase 1 ac is not
present. |
| BE19B25x |
Rack x (x is last digit of reference code), DC-UPS not supplying output power
to phase 3 main output. |
| BE19B27x |
Rack x (x is last digit of reference code), DC-UPS not supplying output power
to phase 2 main output. |
| BE19B29x |
Rack x (x is last digit of reference code), DC-UPS not supplying output power
to phase 1 main output. |
| BE19B2Bx |
Rack x (x is last digit of reference code), DC-UPS not supplying output power
to phase 3 DDM output. |
| BE19B2Dx |
Rack x (x is last digit of reference code), DC-UPS not supplying output power
to phase 2 DDM output. |
| BE19B2Fx |
Rack x (x is last digit of reference code), DC-UPS not supplying output power
to phase 1 DDM output. |
| BE19B37x |
Rack x (x is last digit of reference code), DC-UPS BSM Set 1 not
present. |
| BE19B38x |
Rack x (x is last digit of reference code), DC-UPS BSM Set 1 contactor
open. |
| BE19B3Bx |
Rack x (x is last digit of reference code), DC-UPS BSM Set 1 Battery switch
not open. |
| BE19B3Ex |
Rack x (x is last digit of reference code), DC-UPS BSM Set 1 disconnected
because it has reached battery discharge cutoff. |
| BE19B41x |
Rack x (x is last digit of reference code), DC-UPS BSM Set 2 not
present. |
| BE19B42x |
Rack x (x is last digit of reference code), DC-UPS BSM Set 2 contactor
open. |
| BE19B45x |
Rack x (x is last digit of reference code), DC-UPS BSM Set 2 Battery switch
not open. |
| BE19B48x |
Rack x (x is last digit of reference code), DC-UPS BSM Set 2 disconnected
because it has reached battery discharge cutoff. |
| BE19B4Bx |
Rack x (x is last digit of reference code), DC-UPS BSM Set 3 not
present. |
| BE19B4Cx |
Rack x (x is last digit of reference code), DC-UPS BSM Set 3 contactor
open. |
| BE19B4Fx |
Rack x (x is last digit of reference code), DC-UPS BSM Set 3 Battery switch
not open. |
| BE19B51x |
Rack x (x is last digit of reference code), DC-UPS BSM Set 3 disconnected
because it has reached battery discharge cutoff. |
| BE19B53x |
Rack x (x is last digit of reference code), DC-UPS input circuit breaker
tripped. |
| BE19B55x |
Rack x (x is last digit of reference code), DC-UPS DSU fault. |
| BE19B57x |
Rack x (x is last digit of reference code), DC-UPS BSM set 1 fault. |
| BE19B59x |
Rack x (x is last digit of reference code), DC-UPS BSM set 2 fault. |
| BE19B5Bx |
Rack x (x is last digit of reference code), DC-UPS BSM set 3 fault. |
| BE19B5Dx |
Rack x (x is last digit of reference code), DC-UPS fan fault. |
| BE19B60x |
Rack x (x is last digit of reference code), DC-UPS unsupported
interrupt. |
| BE19B61x |
Rack x (x is last digit of reference code), DC-UPS BSM set E10 has an invalid
serial number in one of the secondary modules. |
| BE19B62x |
Rack x (x is last digit of reference code), DC-UPS BSM set E11 has an invalid
serial number in one of the secondary modules. |
| BE19B63x |
Rack x (x is last digit of reference code), DC-UPS BSM set E12 has an invalid
serial number in one of the secondary modules. |
| BE19B99x |
Rack x (x is last digit of reference code), DC-UPS DSU to BSM Set 1 (-E10)
communications fault. |
| BE19B9Ax |
Rack x (x is last digit of reference code), DC-UPS DSU to BSM Set 2 (-E11)
communications fault. |
| BE19B9Bx |
Rack x (x is last digit of reference code), DC-UPS DSU to BSM Set 3 (-E12)
communications fault. |
| BE19B9Fx |
Rack x (x is last digit of reference code), DC-UPS BSM set 1 has reached end
of life. |
| BE19BAFx |
Rack x (x is last digit of reference code), DC-UPS BSM set 1 date of last
charge greater than 8 months. |
| BE19BB1x |
Rack x (x is last digit of reference code), DC-UPS BSM set 2 has reached end
of life. |
| BE19BC1x |
Rack x (x is last digit of reference code), DC-UPS BSM set 2 date of last
charge greater than 8 months. |
| BE19BC3x |
Rack x (x is last digit of reference code), DC-UPS BSM set 3 has reached end
of life. |
| BE19BD3x |
Rack x (x is last digit of reference code), DC-UPS BSM set 3 date of last
charge greater than 8 months. |
| BE19BD5x |
Rack x (x is last digit of reference code), DC-UPS communication error with
RPC-1. |
| BE19BD6x |
Rack x (x is last digit of reference code), DC-UPS communication error with
RPC-2. |
| BE19BD7x |
Rack x (x is last digit of reference code), DC-UPS communication error with
both RPCs. |
| BE19BD8x |
Rack x (x is last digit of reference code), RPC communication error to both
DC-UPSs. |
| BE19BD9x |
Rack x (x is last digit of reference code), Each DC-UPS is reporting a
communication error to a different RPC. |
| BE19BDAx |
Rack x (x is last digit of reference code), ac input has been restored to this
DC-UPS. |
| BE19BDBx |
Rack x (x is last digit of reference code), The input circuit breaker has been
turned back on this DC-UPS. |
| BE19BF4x |
Rack x (x is last digit of reference code), DC-UPS BSM set 1 (-E10) reported
born-on date more than 2 years out of sync with a partner BSM set. |
| BE19BF5x |
Rack x (x is last digit of reference code), DC-UPS BSM set 2 (-E11) reported
born-on date more than 2 years out of sync with a partner BSM set. |
| BE19BF6x |
Rack x (x is last digit of reference code), DC-UPS BSM set 3 (-E12) reported
born-on date more than 2 years out of sync with a partner BSM set. |
| BE19BF8x |
Rack x (x is last digit of reference code), battery failure threshold was
exceeded. System might not be able to complete FHD. If a power loss occurs, customer data might be
lost. |
| BE19BF9x |
Rack x (x is last digit of reference code), DC-UPS BSM set 1 replacement 9
months early warning. |
| BE19BFAx |
Rack x (x is last digit of reference code), DC-UPS BSM set 2 replacement 9
months early warning. |
| BE19BFBx |
Rack x (x is last digit of reference code), DC-UPS BSM set 3 replacement 9
months early warning. |
| BE19BFCx |
Rack x (x is last digit of reference code), DC-UPS BSM set 1 replacement 3
months early warning. |
| BE19BFDx |
Rack x (x is last digit of reference code), DC-UPS BSM set 2 replacement 3
months early warning. |
| BE19BFEx |
Rack x (x is last digit of reference code), DC-UPS BSM set 3 replacement 3
months early warning. |
| BE19C00x |
Rack x (x is last digit of reference code), DC-UPS-1 to DC-UPS-2 phase 1 ac
crossover cable is disconnected. |
| BE19C01x |
Rack x (x is last digit of reference code), DC-UPS-1 to DC-UPS-2 phase 2 ac
crossover cable is disconnected. |
| BE19C02x |
Rack x (x is last digit of reference code), DC-UPS-1 to DC-UPS-2 phase 3 ac
crossover cable is disconnected. |
| BE19C04x |
Rack x (x is last digit of reference code), both DC-UPSs report partner AC
input status not good on all phases. |
| BE19C05x |
Rack x (x is last digit of reference code), battery test timeout on DC-UPS BSM
set 1. |
| BE19C06x |
Rack x (x is last digit of reference code), battery test timeout on DC-UPS BSM
set 2. |
| BE19C07x |
Rack x (x is last digit of reference code), battery test timeout on DC-UPS BSM
set 3. |
| BE19C08x |
Rack x (x is last digit of reference code), battery test failed to start due
to DC-UPS BSM set 1 errors. |
| BE19C09x |
Rack x (x is last digit of reference code), battery test failed to start due
to DC-UPS BSM set 2 errors. |
| BE19C0Ax |
Rack x (x is last digit of reference code), battery test failed to start due
to DC-UPS BSM set 3 errors. |
| BE19C0Bx |
Rack x (x is last digit of reference code), DC-UPS DSU fault, phase 1 partner
switch opened. |
| BE19C0Dx |
Rack x (x is last digit of reference code), DC-UPS DSU fault, phase 2 partner
switch opened. |
| BE19C0Fx |
Rack x (x is last digit of reference code), DC-UPS DSU fault, phase 3 partner
switch opened. |
| BE19C11x |
Rack x (x is last digit of reference code), DC-UPS BSM set 1 fault, contactor
shorted. |
| BE19C13x |
Rack x (x is last digit of reference code), DC-UPS BSM set 2 fault, contactor
shorted. |
| BE19C15x |
Rack x (x is last digit of reference code), DC-UPS BSM set 3 fault, contactor
shorted. |
| BE19C17x |
Rack x (x is last digit of reference code), battery test stopped due to DC-UPS
BSM set 1 fault. |
| BE19C19x |
Rack x (x is last digit of reference code), battery test stopped due to DC-UPS
BSM set 2 fault. |
| BE19C1Bx |
Rack x (x is last digit of reference code), battery test stopped due to DC-UPS
BSM set 3 fault. |
| BE19C20x |
Rack x (x is last digit of reference code), DC-UPS DSU fault, phase switch
shorted. |
| BE19C21x |
Rack x (x is last digit of reference code), DC-UPS DSU fault, main output over
voltage. |
| BE19D010 |
RPC-1 CPLD clock error |
| BE19D011 |
RPC-2 CPLD clock error |
| BE19D120 |
RPC-1 boot error |
| BE19D121 |
RPC-2 boot error |
| BE19D190 |
RPC-1 has a microcode logic error |
| BE19D191 |
RPC-2 has a microcode logic error. |
| BE19D1C0 |
RPC-1 rebooted due to power fault. |
| BE19D1C1 |
RPC-2 rebooted due to power fault. |
| BE19D1D0 |
RPC-1 rebooted due to unfence by partner RPC. |
| BE19D1D1 |
RPC-2 rebooted due to unfence by partner RPC. |
| BE19D1E0 |
Checksum failure on RPC-1 configuration data in flash memory. |
| BE19D1E1 |
Checksum failure on RPC-2 configuration data in flash memory. |
| BE19DEAD |
Loss of ac or a Force Power Off caused Storage Facility to power off. |