This I/O problem-determination procedure isolates
I/O card and I/O subsystem failures.
PFW1542 Section-1
Procedure
Did you wait a maximum of 10 minutes for the progress code
to change?
Yes, continue with the next step.
No, wait 10 minutes before you continue with the next step
Use Storage Facility
Management > storage facility > Exchange Parts > Exchange CEC Components > Show FRUs > Exchange FRU to
check whether you have a serviceable event to repair
for the failing CEC enclosure. Did you find a serviceable event to repair?
Yes, repair the problem using the serviceable event.
No, continue with the next step.
Use the Service Processor ASMI menu to check for event
logs, which indicate a problem:
No, if a serviceable event was created,
repair the problem using the serviceable event. If the
same SRN error occurs, contact your next
level of support.
Yes, resume the LPAR(s) on the CEC enclosure as
follows:
From the navigation area, click Storage Facility Management > storage
facility > SF image.
From the bottom Task area, click Service
Utilities > Change/Show LPAR State.
On the Server Control Panel, click Resume
LPAR.
If the Resume was successful, then this is the end of
the repair.