MAP4A90 Code update utility process was automatically suspended
About this task
A code update process started by a Utility option has been
automatically suspended by an unexpected problem that should have
created a separate serviceable event from
the one that sent you here.
In addition to the serviceable event that
sent you here, are there any other open serviceable events?
Yes, continue with step 3.
No, go to the next step.
Did you already repair a related serviceable event or problem?
Yes, go to step 4.
No, the code update has failed
with no associated error.
Note: A serviceable event may not be opened
for the problem which caused the update to fail, until one or more
hourly healthchecks have run. If you wish, you may run CDA preverify
now and work with your next level of support to isolate the problem
more quickly.
If you choose to wait for a serviceable event, you
will restart this MAP at step 1 with that serviceable event.
If
you do not wish to wait, run CDA preverify now and then contact your
next level of support with the results.
Find the error messages in the CDA preverify log, and
contact your next level of support.
Display the serviceable event details
for the other serviceable event that
did not send you here. Use Table 1 to
prioritize the repair sequence.
Note: You will not be able
to reselect the serviceable event in the
original window that you used to select it when you began this repair.
Instead, return to the main HMC menu selection and repeat the steps
to view serviceable events.
Table 1. Service repair sequence priority
Serviceable Event Type
Repair Sequence
Action
CEC enclosureserviceable event
1
Repair serviceable event and then
return here and continue.
All other problems except any serviceable event with
MAP4A90 or MAP4AA0 in the FRU list.
2
Repair serviceable event and then
return here and continue.
Serviceable event with MAP4AA0 in FRU list.
3
Close this serviceable event and then
continue.
Close the serviceable event that
sent you here.
Note: There should be no open serviceable events remaining
now.
Exit this MAP and restart the original code update Utility
option from the beginning.