All other serviceable events for
the code update process failure have been repaired. This MAP provides
guidance for special processing that is required before resuming selected
resources. (You will only be sent here from MAP4A30 or MAP4A40.)
Procedure
There should only be one serviceable event left
open from the MAPs that sent you here. Do you have only one serviceable event open,
and is its SRC = BE9CxxC0 or BE9CxxC1?
Note: This is a normal condition during the
code update process that would have been automatically reset if the
code update process had continued without error.
Note: This is a
normal condition during the code update process that would have been
automatically reset if the code update process had continued without
error.
A host adapter card and host adapter port
that has completed its code update will have a state=0. Determine
the state of the host adapter cards and host adapter ports.
The code update may complete successfully
if the card is quiesced and resumed. A pseudo repair using the HMC Exchange
Parts option will be used to force this.
Contact your next level
of support. From the Review Resources State screen,
provide support personnel with the Identifier value (third column)
of the card/port that has a state not equal to 0. (An example of
an Identifier is cpssfc0232.)
Support personnel will need to determine
the specific location of the FRU. This is the MTMS (machine type model
serial) of the I/O enclosure and the physical location (PCIe slot) in which the card resides (for example, U1400.1B2.102ABBA-P1-C3).
Use the location code of the host adapter card to do the
pseudo repair. This means you do the complete replacement procedure
but do not disconnect any cables or remove the host card. Use the
Exchange FRU option to replace the FRU.
From the navigation area, click Storage Facility Management > storage
facility.
From the bottom Task area, click Exchange
Parts. Select the exchange option that contains the FRU
to be exchanged. A window opens and displays the enclosures.
Select the enclosure location code, and then click Show
FRUs.
Select the FRU location code, and then click Exchange
FRUs.
Is the control switch for CUIR (Control Unit
Initiated Request) enabled on the storage
facilities images
that were being updated?
Yes, it is unknown if all customer paths were successfully
restored. Have the customer check and restore their paths or contact your next
level of support for
help if needed. After all customer path access is confirmed, return
here and go to step 14.