This procedure is called for when a error is detected but the management console (HMC) cannot communicate with the Storage Facility Image (SFI) to suspended CDA, or the HMC fails and becomes inaccessible while a code load is in process. CDA attributes are kept in the SFI. For the later condition, no open problems can be viewed.
This MAP is called for when a error is detected but the HMC cannot communicate with the SFI to suspended code update or the HMC fails and becomes inaccessible while a code load is in process. Code update status is kept in the SFI. For the later condition, no open problems can be viewed.
A single HMC can control a code update on more than one storage facility (DS8000®, DS8000, or both) at a time. Only one SFI on each storage facility is updated at a time.
If the HMC itself fails, then more than one code update could also fail. In that case, there should be a separate serviceable event for each code update process. They will be repaired individually.