DS8000 Service Documentation Version 7.5
MAP4090 PCI bus isolation from the HMC
Use this procedure if you are isolating a PCI bus problem
from the HMC.
MAP4090 Section-1
Procedure
- Did the serviceable event view
provide the location(s) for the failing FRU(s)?
- Yes, use those locations to exchange the given FRUs one at
a time until the problem is resolved. This ends the procedure.
- No, contact your next
level of support before
you continue with the next step. This procedure from the eServer service
Information Center assumes knowledge of the HMC options that the storage facility service
representative is not trained with.
- Go to MAP4091 DSA translation to determine the
Direct Select Address (DSA) in decimal value and then return here
and go to the next step.
- Record the Cc value from the
DSA.
Is the Cc value greater
than 00?
- Yes, go to the next step.
- No, the multi-adapter bridge number and the multi-adapter
function number have not been identified, so the card slot cannot
be identified using the DSA. Look in the HMC partition resources for
non-reporting or non-operational hardware. That will indicate which
cards in which positions need to be replaced. If replacing the PCI
card does not fix the problem, replace the backplane that the card
is plugged into. This ends the procedure.
- Is the right-most character (the c character)
F?
- No, go to the next step.
- Yes, only the multi-adapter bridge number has been identified.
Record the multi-adapter bridge number (left-most character of Cc)
for later use. Since the card slot cannot be identified with the DSA,
see . Consider all of the card
slots that are controlled by the multi-adapter bridge to be FRUs. This
ends the procedure.
- Refer to MAP4092 Card positions and
use the BBBB and Cc values
that you recorded to identify the card position. Then return to the
procedure that sent you here. This ends the procedure.