MAP4075 Restoring VPD after replacing the CEC enclosureI/O backplane assembly (Models 94x, 95x)
If you replace the I/O backplane assembly in the CEC enclosure, you must
manually restore the vital product data (VPD) settings. Use this MAP
to restore the settings.
From the ASMI navigation, select System
Configuration > Program Vital Product Data > System Enclosures, then select
the menu option that is listed in the first column of Table 1.
Table 1. System Enclosures menu options
Menu option
Example setting
Source of setting information
Enclosure location
Feature Code/Sequence Number = U789D-001
Enclosure serial number = 00002FA
The label on the front of the CEC enclosure (at the
far right end, between the rack mounting screws, in a vertical orientation)
Click Save Settings. The service
processor might reboot at this point. Wait until the service processor
returns to Standby state before continuing with the next step.
Return to the HMC repair process screen that sent you here
and click Next to continue.