If you replace the service processor in the CEC enclosure, you must manually restore the vital product data (VPD) settings. Use this MAP to restore the settings.
Go to MAP4065 Section-2.
| Menu option | Example settings | Source of setting information |
|---|---|---|
| Time of Day | 01 May 2009 13 : 23 : 19 UTC |
Ensure that the date and time match. The date and time must be entered in Coordinated Universal Time (UTC). |
From the ASMI navigation, select Performance Setup, then select the menu option listed in the first column of Table 2.
| Menu option | Example settings | Source of setting information |
|---|---|---|
| Logical Memory Block Size | 16 | The Setting field
must be set to "16" for DS8000®. Note: If you change this field to "16," ensure you click Save
Settings.
|