DS8000 Service Documentation Version 7.5

MAP2241 Rack battery module set born-on date mismatch

One or more of the battery service module (BSM) sets in the rack has a born-on date that is more than two years older than the BSM set with the newest born-on date.

About this task

MAP2240 Section-1

Procedure

  1. One or more of the BSM sets in the rack has a born-on date that is more than two years older than the BSM set with the newest born-on date in the same rack.
  2. At the front of the rack remove the BSM set black bezel.
    At the top of the bezel, pull toward you until it releases then lift it up off the bottom tabs.
  3. Observe the battery born-on date label on BSM set.

    Is there more than a two-year difference?

    • Yes, go to the next step.
    • No, exit this MAP. All BSM sets are within their limits.
  4. Do you have a serviceable event that lists the location code of the specific battery module set to be replaced? See the lower left of Figure 1 for the location codes (E10, E11, and E12).
    Figure 1. Battery service module (BSM) set locations (front)
    Battery service module (BSM) set locations (front)