MAP20F5 Expansion rack PPS to rack
1 RPC communication problem detected
A PPS to RPC card communication
problem was detected. The problem normally will be mis-plugged PPS
or RPC card cables
detected during an install or repair action.
The RPC to PPS communication
cable is a "Y" cable that connects one RPC card to the
sequencer module in each PPS in a rack. Each rack in the storage facility has
two "Y" cables, one going to each RPC card.
One or more PPS to RPC card cables
have been detected as mis-plugged at PPS-1, PPS-2, or
the RPC card.
This should only occur during an install or repair action that caused
you to connect or reconnect the cables.
Note: If this occurred
during an install, it is possible that a cable was mislabeled. If
a labeling error is found, mark the label so it will not cause future
problems.
Use the tables below to physically trace each cable and
ensure all three ends are correctly plugged. If a problem is found,
you must not hot plug the cables to correct the problem. Instead,
return and repeat the procedure during which the cables were connected.
If this is not possible, contact your next
level of support.