The protected 208 VDC output is off. Either one of the sequencer
module S0, S1, or S2 enable/disable switches is set to disable or the PPS
has a failure.
All LEDs are green, the failure is not occurring now so this MAP will
not be able to isolate it. Exit this MAP and close the problem.
Figure 1. PPS sequencer module and LED enable/disable
switch
Observe the S0, S1, and S2 enable/disable
switches 1 on the sequencer module of the PPS
FRU. Is a switch in the disable position?
Yes, set the switch to the enable position. Return to the repair
process screen and do a pseudo repair (see Note) of the next FRU in the list.
This will run verification tests to ensure the repair is successful.
Note: A
pseudo repair means you use the normal procedures to replace the FRU, but
do not exchange the original FRU with a new FRU. You must still power off
and disconnect the cables when directed. Do not remove or replace the FRU.
Connect and power on the FRU when guided. This ensures the error conditions
are properly reset and all verification tests, including the FRU power-on
self test, are correctly run.
No, return to the repair process screen and continue the repair by
selecting the next FRU on the list.