Visually check both circuit breakers (CBs) on
the battery module enclosure. Find the condition that applies:
CB is in the full OFF (down) position, go to step 2.
CB is not detented in a full OFF (down) or full
ON (up) position, go to step 3.
Note: This
normally occurs if the CB has mechanically failed internally. The
breaker handle will feel like it is loose. When gently moved up or
down, it will not detent in the full up or down position.
Do a pseudo repair of the battery module enclosure
FRU, and set the CB to ON (up) during that repair. A pseudo repair
means you do not actually physically replace the FRU, but you go through
the normal FRU replacement process. If
you have already performed a pseudo repair of the battery module enclosure
FRU and the problem reoccurred, go to step 3.
Click Close in the current service
information window (that is, this window).
One or more HMC repair screens will prompt you for the
result of using the service procedure in the MAP. Select Problem
not fixed.
Select No when prompted for whether
you exchanged any parts.
Select Yes when prompted for
whether you isolated the problem.
Select the FRU to be repaired from the FRU list. Click Next.
The HMC begins the FRU exchange process for the selected
FRU.
When the pseudo repair is complete, return
here and continue.
Inspect the CBs on the other battery module
enclosures in this rack.
If all are in the ON (up) position, exit this MAP, the repair
is complete.
If any are in the OFF (down) position, use their serviceable event
to repair them. If there are no serviceable events for that battery
module enclosure, then do a pseudo repair of that battery module enclosure
to reset the CBs to the ON (up) position using MAP1230 Replace a FRU without using a serviceable event. When all CBs have been
reset, exit this MAP, the repair is complete.
Replace the battery module enclosure FRU.
Click Close in the current service
information window (that is, this window).
One or more HMC repair screens will prompt you for the
result of using the service procedure in the MAP. Select Problem
not fixed.
Select No when prompted for whether
you exchanged any parts.
Select Yes when prompted for
whether you isolated the problem.
Select the FRU to be repaired from the FRU list. Click Next.
The HMC begins the FRU exchange process for the selected
FRU.
Observe the FRU list in the serviceable event that
sent you here. Are there FRUs listed that have not been
replaced yet?
Yes, use the steps below to replace the next FRU
in the list. If the listed FRUs do not fix the problem, replace the
battery module enclosure FRU if it has not been replaced. Then exit
this MAP.
No, use the steps below. Replace the battery module
enclosure FRU if it has not been replaced.
Click Close in the current service
information window (that is, this window).
One or more HMC repair screens will prompt you for the
result of using the service procedure in the MAP. Select Problem
not fixed.
Select No when prompted for whether
you exchanged any parts.
Select Yes when prompted for
whether you isolated the problem.
Select the FRU to be repaired from the FRU list. Click Next.
The HMC begins the FRU exchange process for the selected
FRU.