This MAP procedure is only used when directed by the management console GUI while repairing an open serviceable event.
These FRUs have additional logical procedures that you must do after they are physically replaced.
| If the serviceable event FRU list contains: | Location code | Select this FRU and continue at substep 5.b |
|---|---|---|
| CEC enclosure system backplane
and CEC enclosure VPD card |
Un-P1 Un-P1-C20 |
CEC enclosure system backplane |
| CEC enclosure system backplane
and CEC enclosure time-of-day battery |
Un-P1 Un-P1-E1 |
CEC enclosure system backplane |
| CEC enclosure system backplane | Un-P1 | CEC enclosure system backplane |
| CEC enclosure VPD card | Un-P1-C20 | CEC enclosure VPD card |
| CEC enclosure time-of-day battery | Un-P1-E1 | CEC enclosure time-of-day battery |
| If the serviceable event FRU list contains: | Location code | Select this FRU and continue at substep 6.b |
|---|---|---|
| CEC enclosure memory card and CEC enclosure memory module |
Un-P1-Cxx (xx=15-18) Un-P1-Cxx-Cy (xx=15-18; y=1-4, 7-10) |
CEC enclosure memory module |
| CEC enclosure memory module | Un-P1-Cxx-Cy (xx=15-18; y=1-4, 7-10) | CEC enclosure memory module |
| All other CEC FRUs | N/A | Any FRU listed in the serviceable event FRU list. |