DS8000 Service Documentation Version 7.5
MAP1100 Section-42 Power Control Switch State
Procedure
- Figure 1 is an example
of the details window for the Power Control Switch check.
Figure 1. Window: PowerControl
switch details
- Description: Verifies that Storage Facility powerControlMode
is set to REMOTE or LOCAL. Displays as FAILED in the main panel when:
- powerControlMode attribute is equal to 0 (local)
- powerControlMode attribute is less than -1 and greater than
5 (indicates 'unknown' state)
- Action:
- For Model 941: At the upper left rear of Rack-1,
observe the Local remote switch card white Local/Remote switch. It
should be in the Remote position (up). It should be in the local position
(down) only if directed by next level of support or an isolation MAP
for the special case where the management console could not control
the storage facility power.
- If the state is displayed as LOCAL, observe the white local remote
switch position.
- If the white switch is in LOCAL (down), complete the service action
that had you set it to local. If there is no service action in progress,
reset the switch back to REMOTE.
- If the white switch is in REMOTE (up), there is a problem with
the physical setting of the switch not agreeing with the setting reported
by the code. Call next level of support.
- If the state is displayed as REMOTE, this is correct if the white
switch is in the REMOTE (up) position. If the white switch is in the
LOCAL (down) position, call the next level of support.
Figure 2. 941 Local remote switch cards
- For Model 951: At the upper left rear of Rack-1,
observe the Local remote switch card white Local/Remote switch. It
should be in the Remote position (right). It should be in the local
position (left) only if directed by next level of support or an isolation
MAP for the special case where the management console could not control
the storage facility power.
- If the state is displayed as LOCAL, observe the white local remote
switch position.
- If the white switch is in LOCAL (left), complete the service action
that had you set it to local. If there is no service action in progress,
reset the switch back to REMOTE.
- If the white switch is in REMOTE (right), there is a problem with
the physical setting of the switch not agreeing with the setting reported
by the code. Call next level of support.
- If the state is displayed as REMOTE, this is correct if the white
switch is in the REMOTE (right) position. If the white switch is in
the LOCAL (left) position, call the next level of support.
Figure 3. 951 Local remote switch cards