Note: If the Large File Transfer (the tenth System Check
Type status from the top) is FAILED, this System Check Type cannot
be displayed.
Procedure
Figure 1 is an example
of the detail window for the system power off policy (in this example,
an error condition is not shown).
Figure 1. Window: Systems
power off policy details
Description: Power off policy should be set to 1.
Action: Click Storage Facility Management > storage facility > Service
Utilities > View Storage Facility Power Status and display the Power Status menu options. If nothing
appears incorrect, display and repair any open serviceable events that
are related to the rack power system. If there are none, contact your next
level of support. The
next level of support must remotely connect to
repair this condition.
Next level of support only:
- /opt/hsc/bin/lssyscfg -r sys -F name,power_off_policy
Server-9117-MMA-SN13AABF0,1
Server-9117-MMA-SN100096A,1
Error evaluation:
power_Off_Policy should be set to 1. Anything else is an error.