Explanation
An invalid RIO, HSL or 12X configuration
was detected
Response
Work with the FRU list in the serviceable
event view if there is one, otherwise use the FRU list documented
here to determine the parts to exchange. The four rightmost characters
of word 4 in the reference code represent the Program Return Code
(PRC), which describes the problem detected. The four leftmost digits
of word 7 represent the loop number in hexadecimal format. Convert
the loop number to decimal format before comparing it to loop numbers
shown in serviceable event views and service tools. To determine
the problem, find the PRC in the list below. Note: The FRU description
in the serviceable event view may already contain a message that
identifies the problem.
- xxxx 0000 indicates bus numbers were not assigned. Contact your
next level of support.
- xxxx 0008 indicates the system serial number is not set. Set the
serial number on the system unit. If the problem persists contact
your next level of support.
- xxxx 029A indicates an unsupported I/O tower hardware level.
Upgrade the tower hardware to a supported level.
- xxxx 3201 indicates there are HSL OptiConnect clustered systems
on both RIO or HSL loops on the same adapter. You will need to ensure
that only one RIO or HSL loop per adapter is used for HSL OptiConnect.
- xxxx 3211 indicates two or more HSL adapters are connected to
each other on the same system unit. This is not a supported configuration.
Re-cable the system so that it has a supported configuration.
- xxxx 3212 indicates the HSL adapter hardware level does not support
HSL OptiConnect. Upgrade your HSL adapter hardware to a supported
level for HSL OptiConnect.
- xxxx 3213 indicates that the switchable tower configuration is
not valid. Re-cable your HSL OptiConnect so that it has a supported
configuration.
- xxxx 3217 indicates there is a model 5791, 5792, or 5794 IO drawer
on a loop with clustered systems. This is not a supported configuration.
- xxxx 3218 indicates a concurrent tower add is not allowed due
to an incomplete loop. Look for and resolve errors on the loop.
- xxxx 3219 indicates the 12X cable port connections to the backplane
or riser card of the I/O drawer have been reversed. Return the cables
to their previous port connections.
This ends the procedure.
Problem determination
No action is required.