DS8000 Service Documentation Version 6.3.3

BE3xxxxx

This topic lists the BE3xxxxx system reference codes.

If the SRC listed in a serviceable event is missing from the following table, ask your next level of support for assistance.
Note: Next level, inform development of any SRCs not defined in the table.
Table 1. BE30xxxx system reference codes
System reference code Description
BE30040F Lost access to one half of a mirrored array
BE303200 Loop Empty: Loop restored after darsterror.
BE303201 Loop Empty: Loop restored after HOS reset.
BE303202 Loop Empty: Loop partially restored after HOS reset.
BE303203 Loop Empty: Loop restored after port disable/enable.
BE303204 Loop Empty: Loop partially restored after port disable/enable.
BE303205 Loop Empty: Loop restored after IC card reset.
BE303206 Loop Empty: Loop partially restored after IC card reset.
BE303207 Loop Empty: Bad FCIC.
BE303208 Loop Empty: Utility was not able to recover loop.
BE304000 The ISS adapter card has failed.
BE304010 No SDRAM module detected or POST is unable to determine the SDRAM size.
BE304012 A 256 MB SDRAM module has failed.
BE304060 Device Adapter Power On Self Test detected compact flash failure.
BE304062 Device Adapter flash memory card has reached its end of life.
BE304063 The flash memory card is missing.
BE304064 The Compact Flash card is downlevel, and needs to be upgraded in order to support RAID6.
BE304088 Array is offline because there are insufficient drives in the array to maintain data availability.
BE30408A DA failover failed. The array is offline as a missing adapter contains APU data that cannot be reconstructed locally.
BE30408C An array member is missing and the opening adapter is not available.
BE304090 Array offline, adapter has full APU.
BE304094 Part of the array data might have been lost.
BE3040A0 ISP failure.
BE3040A4 The ISS adapter has detected a loop configuration that is not valid.
BE3040A8 An array filter has detected a loop configuration that is not valid.
BE3040AC Array is offline because some of its members are only connected to one adapter and some are connected to both adapters.
BE3040B0 A RAID-10 array is offline because the primary/secondary half of the array is not present.
BE3040B2 A RAID-10 array is offline because only one half of the array is present and that half contains an out-of-date copy of the data.
BE3040B4 All the primary or all the secondary disks of a RAID-10 array are present, but the adapter is unknown to the array.
BE3040BC The Invalid-strip-table is full. Because of failures on multiple member disk drives of an array, at least 448 blocks of data are not accessible. Other data on the array might still be readable.
BE3040BD Parity Resync table full. Array has gone offline.
BE3040C0 Array not available - multiple device failures.
BE3040C4 A disk drive has caused an array building operation to fail.
BE3040C6 A RAID-6 array is in the Critical state because 2 disk drives are not available to the array and a write command has been sent to that array.
BE3040C8 An array is in the Degraded state because a DDM is not available to the array and a write command has been sent to that array.
BE3040CC An array is in the Exposed state because a DDM is not available to the array.
BE3040CD Device adapter internal error: DAHP disabled.
BE3040D0 A different adapter has been detected on each loop.
BE3040D4 Disused loop.
BE3040D8 Disused FC chip.
BE3040D9 The number of drive bias swaps has exceeded threshold. Device adapter firmware has placed the FCAL loop into service mode.
BE304100 No hot spare disk drives are available for an array that is configured for hot spare disk drives.
BE304440 There is one device that only has a single active port.
BE304442 There are multiple devices that only have a single active port.
BE304460 NVRAM failure.
BE304461 Correctable NVRAM error threshold exceeded.
BE304471 Control store single-bit error.
BE304472 Data store single-bit error.
BE305000 Unable to read or write to the PCI configuration space.
BE305004 An ISS adapter or device driver protocol error has occurred.
BE305008 The ISS adapter microcode has hung.
BE30500C The ISS adapter card has failed.
BE305010 An attempt was made to log an error against a pdisk that is not available to the using system.
BE305020 Duplicate node number detected.
BE305D00 Dump available on disk.
BE305F00 The ISS adapter microcode has hung.
BE306002 Device asynchronous health check.
BE306004 Device has been reset due to invalid SCSI protocol.
BE306006 The device adapter issued a reset to a device.
BE306008 A device has a Failed status.
BE30600C Device not initialized, unsupported device.
BE30600E Disk drive is only visible on a single-active network and it is in use by another adapter.
BE306010 A device port has been marked disused by the Device Adapter.
BE306011 A device is present but it is not logged-in through either of its ports.
BE306012 A device is present but Port Login was rejected on both ports.
BE306015 Lost data frame (incorrect transfer length).
BE306016 Lost non-data frame.
BE306017 Device failed initialization.
BE306018 Slow device threshold exceeded.
BE30CE24 Device adapter showstop because of double bit error in L2 cache.
BE30CE79 FATA disk drive utilization exceeds specification. Array throughput is now limited. Informational only, no repair necessary.
BE30CE80 ER adapter showstop threshold exceeded, DA fenced was last path to data.
BE30CE81 ER adapter showstop threshold exceeded, DA fenced was not last path to data.
BE30CE7A FATA disk drive utilization now within specification. Array throughput no longer limited. Informational only, no repair necessary.
BE30CE95 DA Datapath Error: Physical Address Check (true).
BE30CE96 DA Datapath Error: Physical Address Check (false).
BE30CE97 Bad LRC on DA Global Meta Data.
BE30CEB0 Physical volume hardware error.
BE30CEB1 Physical volume media error.
BE30CEB2 Physical volume recovered media error.
BE30CEB3 DASD detected software error.
BE30CEB4 Device adapter hardware error.
BE30CEB5 ISS software or firmware error.
BE30CEB6 Adapter detected device error.
BE30CEB7 Loop error.
BE30CEB8 ISS degraded condition.
BE30CEB9 ISS RAID array error.
BE30CEBA ISS configuration error.
BE30CEBB ISS flash memory error.
BE30CEBC ISS event.
BE30CEBD Unable to log an error against a pdisk.
BE30CEBE Enclosure error.
BE30CEBF Enclosure critical temperature.
BE30CEC0 Enclosure temperature warning.
BE30CEC1 Adapter detected device error event.
BE30CECE Split network error detected.
Table 2. BE31xxxx system reference codes
System reference code Description
BE310000 DDM Reported Error: No Additional Sense Information
BE310001 DDM format failed
BE310002 DDM initsurf failed
BE310003 DDM certify failed
BE310004 SCSI sense data error: Beginning of partition/medium detected.
BE310005 SCSI sense data error: End of data detected.
BE310006 SCSI sense data error: I/O process terminated.
BE310011 SCSI sense data error: Audio play operation in progress.
BE310012 SCSI sense data error: Audio play operation paused.
BE310013 SCSI sense data error: Audio play operation successfully completed.
BE310014 SCSI sense data error: Audio play operation stopped due to error.
BE310015 SCSI sense data error: No current audio status to return.
BE310016 SCSI sense data error: Code/Qualifier 00/16.
BE310100 SCSI sense data error: No Index/Logical Block Signal
BE310200 SCSI sense data error: No Seek Complete
BE310300 SCSI sense data error: Peripheral Device Write Fault
BE310301 SCSI sense data error: No write current.
BE310302 SCSI sense data error: Excessive write errors.
BE310400 SCSI sense data error: Logical Unit Not Ready, Start motor failed
BE310401 SCSI sense data error: Logical Unit Not Ready, Becoming Ready
BE310402 SCSI sense data error: Logical Unit Not Ready, Initializing Command Required
BE310403 SCSI sense data error: Logical Unit Not Ready, Manual Intervention Required
BE310404 SCSI sense data error: Logical Unit Not Ready, Format in Progress
BE310408 A drive has been removed from the array by RAID
BE310409 SCSI sense data error: Self-test in progress
BE31040B Array member marked Rejected
BE310411 Member slow on read
BE310412 Member slow on write
BE310483 A hot spare drive has been rejected because a fault has been found with it.
BE310500 SCSI sense data error: Logical unit does not respond to selection.
BE310600 SCSI sense data error: Reference position found.
BE310700 SCSI sense data error: Multiple peripheral devices selected.
BE310800 SCSI sense data error: Logical Unit Communication Failure
BE310801 SCSI sense data error: Logical Unit Communication Time-Out
BE310802 SCSI sense data error: Logical Unit Communication Parity Error
BE310900 SCSI sense data error: Track Following Error
BE310901 SCSI sense data error: Servo Fault
BE310902 SCSI sense data error: Focus servo failure.
BE310903 SCSI sense data error: Spindle servo failure.
BE310904 SCSI sense data error: Head Select Fault
BE310A00 SCSI sense data error: Error Log Overflow
BE310B01 SCSI sense data error: Temperature warning error
BE310C00 SCSI sense data error: Write Error
BE310C01 SCSI sense data error: Write Error Recovered With Auto-Reallocation
BE310C02 SCSI sense data error: Write Error - Auto Reallocation Failed
BE310C03 SCSI sense data error: Recovered write error - Recommend reassign
BE310C81 SCSI sense data error: Code/Qualifier 0C/81.
BE311000 SCSI sense data error: ID CRC Or ECC Error
BE311100 DDM Error Threshold Exceeded: Unrecovered Read Error
BE311101 SCSI sense data error: Read Retries Exhausted
BE311102 SCSI sense data error: Error Too Long To Correct
BE311103 SCSI sense data error: Multiple read errors.
BE311104 SCSI sense data error: Unrecovered Read Error - Auto Reallocation Failed
BE311105 SCSI sense data error: L-EC uncorrectable error.
BE311106 SCSI sense data error: CIRC unrecovered error.
BE311107 SCSI sense data error: Data resynchronization error.
BE311108 SCSI sense data error: Incomplete block read.
BE311109 SCSI sense data error: No gap found.
BE31110A SCSI sense data error: Miscorrected error.
BE31110B SCSI sense data error: Unrecovered read error - recommend reassignment.
BE31110C SCSI sense data error: Unrecovered read error - recommend re-write the data.
BE311181 SCSI sense data error: Code/Qualifier 11/81.
BE311200 SCSI sense data error: Address Mark Not Found For ID Field
BE311201 SCSI sense data error: Recovered Data Without ECC Using Previous Logical Block ID
BE311202 SCSI sense data error: Recovered Data With ECC Using Previous Logical Block ID
BE311300 SCSI sense data error: Address mark not found for data field.
BE311400 SCSI sense data error: Logical Block Not Found
BE311401 SCSI sense data error: Record Not Found
BE311405 SCSI sense data error: Recovered record not found - Recommend reassign
BE311500 SCSI sense data error: Random Positioning Error
BE311501 SCSI sense data error: Mechanical Positioning Error
BE311502 SCSI sense data error: Positioning Error Detected By Read Of Medium
BE311600 SCSI sense data error: Data Synchronization Mark Error
BE311602 SCSI sense data error: Recovered write error, data sync error - Recommend rewrite
BE311604 SCSI sense data error: Recovered write error, data sync error - Recommend reassign
BE311700 SCSI sense data error: Recovered Data With No Error Correction Applied
BE311701 SCSI sense data error: Recovered Data Using Retries
BE311702 SCSI sense data error: Recovered Data Using Positive Offset
BE311703 SCSI sense data error: Recovered Data Using Negative Offset
BE311704 SCSI sense data error: Recovered data with retries and/or CIRC applied
BE311705 SCSI sense data error: Recovered Data Using Previous Logical Block ID
BE311706 SCSI sense data error: Recovered Data Without ECC - Data Auto Reallocated
BE311707 SCSI sense data error: Recovered data without ECC - recommend reassignment.
BE311708 SCSI sense data error: Recovered data without ECC - recommend rewrite.
BE311800 SCSI sense data error: Recovered Data With ECC
BE311801 SCSI sense data error: Recovered Data With ECC And Retries Applied
BE311802 SCSI sense data error: Recovered Data With ECC And/Or Retries, Data Auto-Reallocated
BE311803 SCSI sense data error: Recovered data with CIRC.
BE311804 SCSI sense data error: Recovered data with LEC.
BE311805 SCSI sense data error: Recovered read error with ECC - Recommend reassign
BE311806 SCSI sense data error: Recovered data using ECC and offsets
BE311807 SCSI sense data error: Recovered Data With ECC - Data Rewritten
BE311886 SCSI sense data error: Recovered read error with ECC (6 symbols)
BE311887 SCSI sense data error: Recovered read error with ECC (7 symbols)
BE311888 SCSI sense data error: Recovered read error with ECC (8 symbols)
BE311889 SCSI sense data error: Recovered read error with ECC (9 symbols)
BE31188A SCSI sense data error: Recovered read error with ECC (10 symbols)
BE311900 SCSI sense data error: Defect List Error
BE311901 SCSI sense data error: Defect List Not Available
BE311902 SCSI sense data error: Defect List Error In Primary List
BE311903 SCSI sense data error: Defect List Error in Grown List
BE311A00 SCSI sense data error: Parameter List Length Error
BE311B00 SCSI sense data error: Synchronous Data Transfer Error
BE311C00 SCSI sense data error: Defect List Not Found
BE311C01 SCSI sense data error: Primary Defect List Not Found
BE311C02 SCSI sense data error: Grown Defect List Not Found
BE311C83 SCSI sense data error: Unique Diagnostic Code
BE311D00 SCSI sense data error: Miscompare During Verify Operation
BE311D06 SCSI sense data error: Data integrity check took >650ms on 5 consecutive readings
BE311D07 SCSI sense data error: Data integrity check failed read/write diagnostic test
BE311E00 SCSI sense data error: Recovered ID with ECC.
BE311F00 SCSI sense data error: Partial defect list transferred
BE312000 SCSI sense data error: Invalid Command Operation Code
BE312100 SCSI sense data error: Logical Block Address Out Of Range
BE312101 SCSI sense data error: Invalid element address.
BE312200 SCSI sense data error: Illegal function (should use 20 00, 24 00, or 26 00).
BE312345 SCSI sense data error: Code/Qualifier 23/45
BE312400 SCSI sense data error: Invalid Field In CDB
BE312500 SCSI sense data error: Logical Unit Not Supported
BE312600 SCSI sense data error: Invalid Field In Parameter List
BE312601 SCSI sense data error: Parameter Not Supported
BE312602 SCSI sense data error: Parameter Value Invalid
BE312603 SCSI sense data error: Invalid Field Parameter - Threshold Parameter
BE312610 SCSI sense data error: Code/Qualifier 26/10
BE312698 SCSI sense data error: Invalid Field Parameter - Check Sum
BE312699 SCSI sense data error: Invalid Field Parameter - Firmware Tag
BE312700 SCSI sense data error: Write Protected
BE312800 SCSI sense data error: Not ready to ready transition (medium may have changed).
BE312801 SCSI sense data error: Import or export element accessed.
BE312900 SCSI sense data error: Power On, Reset, Or Bus Device Reset Occurred
BE312901 SCSI sense data error: Power-On Reset Occurred
BE312902 SCSI sense data error: SCSI Bus Reset Occurred
BE312903 SCSI sense data error: Bus Device Reset Function Occurred
BE312904 SCSI sense data error: Device Internal Reset Occurred
BE312905 SCSI sense data error: Transceiver Mode Changed To Single-Ended
BE312906 SCSI sense data error: Transceiver Mode Changed To LVD
BE312A01 SCSI sense data error: Mode Parameters Changed
BE312A02 SCSI sense data error: Log Parameters Changed
BE312A03 SCSI sense data error: Reservations preempted
BE312B00 SCSI sense data error: Copy cannot execute since host cannot disconnect.
BE312B10 SCSI sense data error: Code/Qualifier 2B/10
BE312C00 SCSI sense data error: Command Sequence Error
BE312C01 SCSI sense data error: Too many windows specified.
BE312C02 SCSI sense data error: Invalid combination of windows specified.
BE312D00 SCSI sense data error: Overwrite error on update in place.
BE312E10 SCSI sense data error: Code/Qualifier 2E/10
BE312F00 SCSI sense data error: Tagged Commands Cleared By Another Initiator
BE313000 SCSI sense data error: Incompatible medium installed.
BE313001 SCSI sense data error: Cannot read medium - unknown format.
BE313002 SCSI sense data error: Cannot read medium - incompatible format.
BE313003 SCSI sense data error: Cleaning cartridge installed.
BE313010 SCSI sense data error: Code/Qualifier 30/10
BE313100 SCSI sense data error: Medium Format Corrupted
BE313101 SCSI sense data error: Format Failed
BE313191 SCSI sense data error: Format Corrupted, World Wide Name (WWN) Is Invalid
BE313200 SCSI sense data error: No Defect Spare Location Available
BE313201 SCSI sense data error: Defect list update Error
BE313202 SCSI sense data error: No Spares Available - Too Many Defects On One Track
BE313500 SCSI sense data error: Code/Qualifier 35/00.
BE313501 SCSI sense data error: Code/Qualifier 35/01, unsupported storage enclosure function.
BE313502 SCSI sense data error: Enclosure services unavailable
BE313610 SCSI sense data error: Code/Qualifier 36/10
BE313700 SCSI sense data error: Parameter Rounded
BE313900 SCSI sense data error: Saving parameters not supported.
BE313910 SCSI sense data error: Code/Qualifier 39/10
BE313D00 SCSI sense data error: Invalid Bits In Identify Message
BE313E00 SCSI sense data error: Logical Unit Has Not Self Configured Yet
BE313F00 SCSI sense data error: Target Operating Conditions Have Changed
BE313F01 SCSI sense data error: Microcode Changed
BE313F02 SCSI sense data error: Changed Operating Definition
BE313F03 SCSI sense data error: Inquiry data has changed.
BE313F0F SCSI sense data error: Echo buffer overwritten
BE313F90 SCSI sense data error: Invalid APM Parameters
BE313F91 SCSI sense data error: World Wide Name (WWN) Mismatch
BE314000 SCSI sense data error: RAM failure.
BE314001 SCSI sense data error: DRAM Parity Error
BE314080 SCSI sense data error: Degraded mode, diagnostics fail
BE314081 SCSI sense data error: Degraded mode, hardware error
BE314082 SCSI sense data error: Diagnostics failure, inconsistent data
BE314083 SCSI sense data error: Diagnostics failure, HDA diagnostics
BE314084 SCSI sense data error: Diagnostics failure, PCB diagnostics
BE314085 SCSI sense data error: Diagnostic failure, RAM microcode not loaded
BE314090 SCSI sense data error: Seek test failure
BE3140A0 SCSI sense data error: Read/write test failure
BE3140B0 SCSI sense data error: Diagnostic failure, self reset
BE3140C5 SCSI sense data error: Diagnostic failure
BE3140D0 SCSI sense data error: Component mismatch
BE314100 SCSI sense data error: Data path failure.
BE314200 SCSI sense data error: Power-On Or Self-Test Failure
BE314300 SCSI sense data error: Message Reject Error
BE314400 SCSI sense data error: Internal Target Failure
BE3144B6 SCSI sense data error: Code/Qualifier 44/B6
BE3144D7 SCSI sense data error: Code/Qualifier 44/D7
BE3144DC SCSI sense data error: Code/Qualifier 44/DC
BE314500 SCSI sense data error: Select/Reselection Failure
BE314600 SCSI sense data error: Unsuccessful soft reset.
BE314700 SCSI sense data error: SCSI Parity Error
BE314701 SCSI sense data error: Code/Qualifier 47/01.
BE314800 SCSI sense data error: Initiator Detected Error Message Received
BE314900 SCSI sense data error: Invalid Message Error
BE314A00 SCSI sense data error: Command phase error.
BE314B00 SCSI sense data error: Data phase error.
BE314C00 SCSI sense data error: Logical Unit Failed Self-Configuration
BE314E00 SCSI sense data error: Overlapped Commands Attempted
BE314F00 SCSI sense data error: Aborted Command due to loop initialization
BE315100 SCSI sense data error: Code/Qualifier 51/00.
BE315400 SCSI sense data error: SCSI to host system interface failure.
BE315500 SCSI sense data error: System resource failure.
BE315B00 SCSI sense data error: Log Exception
BE315B01 SCSI sense data error: Threshold Condition Met
BE315B02 SCSI sense data error: Log Counter At Maximum
BE315B03 SCSI sense data error: Log List Codes Exhausted
BE315C00 SCSI sense data error: RPL Status Change
BE315C01 SCSI sense data error: Spindles Synchronized
BE315C02 SCSI sense data error: Spindles Not Synchronized
BE315D00 SCSI sense data error: Predictive Failure Analysis Threshold Exceeded
BE315DFF SCSI sense data error: Predictive Failure Analysis test warning
BE316000 SCSI sense data error: Lamp Failure.
BE316002 Disk drive asynchronous health check - replace disk.
BE316003 Transient LRC error in a single Block.
BE316004 Drive has been reset due to invalid SCSI protocol.
BE316005 The disk drive reallocation exceeded (no space left.)
BE316006 The disk drive has been reset by the adapter. The disk drive may be about to fail.
BE316007 I/O queued too long
BE316008 A disk drive module has a "Failed" status.
BE316009 The adapter is unable to initialize a device.
BE31600B Disk drive not initialized, capacity too small
BE31600C Disk drive not initialized, unsupported device
BE316010 Disused Device Port
BE316011 A device is present but it is not logged-in through either of its ports.
BE316012 A device is present but Port Login was rejected on both ports.
BE316013 Permanent unrecoverable LRC errors in multiple Blocks.
BE316014 Permanent unrecoverable LRC error in a single Block.
BE316017 Disk drive failed initialization.
BE316018 Slow disk threshold exceeded.
BE316021 Security In Doubt Drive.
BE316023 Security Degraded Drive.
BE316200 SCSI sense data error: Scan head positioning error.
BE316300 SCSI sense data error: End of user area encountered on this track.
BE316400 SCSI sense data error: Illegal mode for this track.
BE316500 SCSI sense data error: Voltage Fault
BE318000 SCSI sense data error: General Firmware Error Qualifier
BE318001 SCSI sense data error: Code/Qualifier 80/01.
BE318002 SCSI sense data error: Code/Qualifier 80/02.
BE318003 SCSI sense data error: Code/Qualifier 80/03.
BE318004 SCSI sense data error: Code/Qualifier 80/04.
BE318005 SCSI sense data error: Code/Qualifier 80/05.
BE318006 SCSI sense data error: Code/Qualifier 80/06.
BE318007 SCSI sense data error: Code/Qualifier 80/07.
BE318087 I/O Error Detection and Correction Checksum (IOEDC) Error on Write.
BE31808A SCSI sense data error: Code/Qualifier 80/8A
BE31808B SCSI sense data error: Code/Qualifier 80/8B
BE31808C SCSI sense data error: Code/Qualifier 80/8C
BE318100 SCSI sense data error: Internal Logic Error
BE318101 SCSI sense data error: Code/Qualifier 81/01.
BE318102 SCSI sense data error: Code/Qualifier 81/02.
BE318103 SCSI sense data error: Code/Qualifier 81/03.
BE318104 SCSI sense data error: Code/Qualifier 81/04.
BE318105 SCSI sense data error: Code/Qualifier 81/05.
BE318106 SCSI sense data error: Code/Qualifier 81/06.
BE3188FE SCSI sense data error: Code/Qualifier 88/FE
BE31CFE7 Security Degraded condition detected during security healthcheck.
BE31CFE8 Band mismatch condition detected during security healthcheck.
BE31CFE9 Security In Doubt condition detected during security healthcheck.
BE31F001 SCSI sense data error: Filemark detected.
BE31F002 SCSI sense data error: End-of-partition/medium detected.
BE31F003 SCSI sense data error: Setmark detected.
BE31F004 DDM Reported Error: PIN Migration failed.
BE31F005 DDM Reported Error: FDE spare enrollment failed.
Table 3. BE32xxxx system reference codes
System reference code Description
BE320010 Invalid storage enclosure CuDv or CuAt ODM object.
BE320200 Ferroelectric random access memory (FRAM) test failed.
BE320202 EPOW signal from power supply unit (PSU) 1 detected active.
BE320203 EPOW signal from power supply unit (PSU) 2 detected active.
BE320204 EPOW_C asserted due to both PsnEPOWe inputs asserted.
BE320205 Targeted loop initialization primitive received.
BE320207 Erase failure of storage enclosure EEPROM 1.
BE320208 Write failure of storage enclosure EEPROM 1.
BE320209 Read failure of storage enclosure EEPROM 1.
BE32020A Checksum failure of storage enclosure EEPROM 1.
BE32020B Erase failure of storage enclosure EEPROM 2.
BE32020C Write failure of storage enclosure EEPROM 2.
BE32020D Read failure of storage enclosure EEPROM 2.
BE32020E Checksum failure of storage enclosure EEPROM 2.
BE32020F Erase failure on Enclosure Controller Module (ECM) VPD.
BE320210 Write failure on Enclosure Controller Module (ECM) VPD.
BE320211 Read failure on Enclosure Controller Module (ECM) VPD.
BE320212 Checksum failure on Enclosure Controller Module (ECM) VPD.
BE320213 VPD erase failure on power supply unit (PSU) 1.
BE320214 VPD write failure on power supply unit (PSU) 1.
BE320215 VPD read failure on power supply unit (PSU) 1.
BE320216 VPD checksum failure on power supply unit (PSU) 1.
BE320217 VPD erase failure on power supply unit (PSU) 2.
BE320218 VPD write failure on power supply unit (PSU) 2.
BE320219 VPD read failure on power supply unit (PSU) 2.
BE32021A VPD checksum failure on power supply unit (PSU) 2.
BE32021B Checksum/read failures of both storage enclosure EEPROMs.
BE32021C Storage enclosure EEPROMs contain different data.
BE32021D Frame received violating interlocked rules.
BE32021E Internal SerDes error on all ports.
BE32021F Enclosure Controller Module (ECM) not compatible with the enclosure.
BE320223 Temperature does not decrease after speeding up fans.
BE320224 Storage enclosure I2C Bus failure reported on power supply unit (PSU) 1.
BE320225 Storage enclosure I2C Bus failure reported on power supply unit (PSU) 2.
BE320226 Storage enclosure I2C Bus failure reported on midplane VPD EEPROM 1.
BE320227 Storage enclosure I2C Bus failure reported on midplane VPD EEPROM 2.
BE320228 Storage enclosure I2C Bus timeouts reported on power supply unit (PSU) 1.
BE320229 Storage enclosure I2C Bus timeouts reported on power supply unit (PSU) 2.
BE32022A Storage enclosure I2C Bus timeouts reported on midplane VPD EEPROM 1.
BE32022B Storage enclosure I2C Bus timeouts reported on midplane VPD EEPROM 2.
BE32022C Power supply unit (PSU) 1 reports different value than what enclosure controller module (ECM) 1 is driving for Power_Off signal.
BE32022D Power supply unit (PSU) 1 reports different value than what enclosure controller module (ECM) 2 is driving for Power_Off signal.
BE32022E Power supply unit (PSU) 1 reports different value than what enclosure controller module (ECM) 1 is driving for Present signal.
BE32022F Power supply unit (PSU) 1 reports different value than what enclosure controller module (ECM) 2 is driving for Present signal.
BE320230 Power supply unit (PSU) 2 reports different value than what enclosure controller module (ECM) 1 is driving for Power_Off signal.
BE320231 Power supply unit (PSU) 2 reports different value than what enclosure controller module (ECM) 2 is driving for Power_Off signal.
BE320232 Power supply unit (PSU) 2 reports different value than what enclosure controller module (ECM) 1 is driving for Present signal.
BE320233 Power supply unit (PSU) 2 reports different value than what enclosure controller module (ECM) 2 is driving for Present signal.
BE320235 Power supply unit (PSU) 1 status signal (Present) mismatch between the enclosure controller modules (ECM).
BE320236 Power supply unit (PSU) 2 status signal (Present) mismatch between the enclosure controller modules (ECM).
BE320237 Power supply unit (PSU) 1 status signal (Alert) mismatch between the enclosure controller modules (ECM).
BE320238 Power supply unit (PSU) 2 status signal (Alert) mismatch between the enclosure controller modules (ECM).
BE320239 Power supply unit (PSU) 1 communication failure.
BE32023A Power supply unit (PSU) 2 communication failure.
BE32023C Maximum number of storage enclosures exceeded on a loop of storage enclosures.
BE32023D Inconsistent storage enclosure topology.
BE32023E Two storage enclosures have the same ID.
BE32023F Invalid topology configuration.
BE320240 Storage enclosure is incorrectly cabled. Crossed A and B sides within one loop of enclosures.
BE320241 Storage enclosure is incorrectly cabled. Connection to bottom of stack of enclosures.
BE320242 Storage enclosure is incorrectly cabled. Connecting one enclosure to more than two other enclosures.
BE320243 Storage enclosure is incorrectly cabled. Single cascade connection.
BE320244 Storage enclosure is incorrectly cabled. The enclosure is not in the correct sequence.
BE320245 Unsupported frame (not DATA, XFER_RDY, or RESPONSE).
BE320246 Boot image CRC error.
BE320247 Programmable Interface Controller (PIC) image CRC error.
BE320248 Phy (SerDes) Controller (PHYC) image CRC error.
BE320249 Complex Programmable Logic Device (CPLD) image CRC error.
BE32024A Image upgrade failure for Boot-Loader.
BE32024B Image upgrade failure for Programmable Interface Controller (PIC).
BE32024C Image upgrade failure for Phy (SerDes) Controller (PHYC).
BE32024D Image upgrade failure for Complex Programmable Logic Device (CPLD).
BE32024E Failure to claim arbitrated loop physical address (ALPA).
BE32024F End of frame (EOF) or Start of frame (SOF) error.
BE320250 FIFO overflow.
BE320251 Ox_ID/RD_ID not matching expected value.
BE320252 Non Class 3 frame detected.
BE320253 Fibre Channel frame received that was below expected size.
BE320254 Fibre Channel frame received that exceeded expected size.
BE320255 Fibre Channel frame received without credit.
BE320256 Resource recovery timeout value (R_R_TOV) sequence initiative.
BE320258 Context (TAG) out of range.
BE32025A Context (TAG) inactive.
BE32025B ICT (Initiator Connection Tag) mismatch.
BE32025D No acknowledgement (NAK) received from Programmable Interface Controller (PIC).
BE32025E Time out in Programmable Interface Controller (PIC) communication.
BE32025F Alternate Enclosure Controller Module (ECM) power fail.
BE320260 Alternate Enclosure Controller Module (ECM) has Programmable Interface Controller (PIC) communication problem.
BE320261 Address mismatch during OPEN Address Frame.
BE320262 Hash check failed for source or destination address.
BE320263 Data frame payload length zero or XFER_RDY requesting zero data.
BE320264 Temperature sensor failure - power supply unit (PSU) 1.
BE320265 Temperature sensor failure - power supply unit (PSU) 2.
BE320266 Alternate Enclosure Controller Module (ECM) Programmable Interface Controller (PIC) watchdog reset.
BE320268 Loss of power on one power supply - power supply unit (PSU) 2.
BE320269 No EPOW signal when power supply removed - power supply unit (PSU) 2.
BE32026A False PSnEPOWe signal. PSnEPOWe asserted but power supply reports good - power supply unit (PSU) 2.
BE32026C Stuck in initialization (LIP -> CLS).
BE320270 Both Enclosure Controller Modules (ECM) in an enclosure have the same Slot ID.
BE320271 Fourth unexpected or self-initiated reboot in 24 hours.
BE320272 Over temperature, warning threshold exceeded.
BE320273 Temperature sensor failure - Enclosure Controller Module (ECM).
BE320274 Fan failure. Fan speed different than set fan speed. - power supply unit (PSU) 1, fan 1.
BE320275 Fan failure. Fan speed different than set fan speed. - power supply unit (PSU) 1, fan 2.
BE320276 Fan failure. Fan speed different than set fan speed. - power supply unit (PSU) 1, fan 3.
BE320277 Fan failure. Fan speed different than set fan speed. - power supply unit (PSU) 1, fan 4.
BE320278 Fan failure. Fan speed different than set fan speed. - power supply unit (PSU) 2, fan 1.
BE320279 Fan failure. Fan speed different than set fan speed. - power supply unit (PSU) 2, fan 2.
BE32027A Fan failure. Fan speed different than set fan speed. - power supply unit (PSU) 2, fan 3.
BE32027B Fan failure. Fan speed different than set fan speed. - power supply unit (PSU) 2, fan 4.
BE32027C Power supply unit (PSU) 1, DC over voltage.
BE32027D Power supply unit (PSU) 2, DC over voltage.
BE32027E Power supply unit (PSU) 1, PS_ALERT signal active but no error reported.
BE32027F Power supply unit (PSU) 2, PS_ALERT signal active but no error reported.
BE320280 Voltage sensor reading above/below thresholds - (12v In OV).
BE320281 Voltage sensor reading above/below thresholds - (5v ECM OV).
BE320282 Voltage sensor reading above/below thresholds - (5v Standby OV).
BE320283 Voltage sensor reading above/below thresholds - (3.3v ECM OV).
BE320284 Voltage sensor reading above/below thresholds - (1.8v ECM OV).
BE320285 Voltage sensor reading above/below thresholds - (1.2v ECM OV).
BE320286 Voltage sensor reading above/below thresholds - (1.5v ECM OV).
BE320287 Voltage sensor reading above/below thresholds - (3v ECM OV).
BE320288 Voltage sensor reading above/below thresholds - (2.5v ECM, SOC PLL1 OV).
BE320289 Voltage sensor reading above/below thresholds - (2.5v ECM, SOC PLL2 OV).
BE32028A Voltage sensor reading above/below thresholds - (3.3v Standby OV).
BE32028B Voltage sensor reading above/below thresholds - (12v In UV).
BE32028C Voltage sensor reading above/below thresholds - (5v ECM UV).
BE32028D Voltage sensor reading above/below thresholds - (5v Standby UV).
BE32028E Voltage sensor reading above/below thresholds - (3.3v ECM UV).
BE32028F Voltage sensor reading above/below thresholds - (1.8v ECM UV).
BE320290 Voltage sensor reading above/below thresholds - (1.2v ECM UV).
BE320291 Voltage sensor reading above/below thresholds - (1.5v ECM UV).
BE320292 Voltage sensor reading above/below thresholds - (3v ECM UV).
BE320293 Voltage sensor reading above/below thresholds - (2.5v ECM, SOC PLL1 UV).
BE320294 Voltage sensor reading above/below thresholds - (2.5v ECM, SOC PLL2 UV).
BE320295 Voltage sensor reading above/below thresholds - (3.3v Standby UV).
BE320296 Over temperature, critical threshold exceeded.
BE320297 Alternate Enclosure Controller Module (ECM) over voltage.
BE320298 Alternate Enclosure Controller Module (ECM) under voltage.
BE320299 Intra Enclosure Controller Module (ECM) communication fails on both paths.
BE32029A Watchdog timer expired.
BE32029B Enclosure program encountered error (Assert).
BE32029C Enclosure program encountered error (Exception ISR).
BE32029D Intra Enclosure Controller Module (ECM) communication fails on single path.
BE32029E Internal Parity Error in Switch on a chip (SOC) Domain.
BE32029F Transient parity error - Port Logic.
BE3202A0 Transient parity error - Bridge Logic.
BE3202A2 Processor Virtual Port (PVP) internal errors.
BE3202A3 Alternate Enclosure Controller Module (ECM) reports EPOW_C but EPOW not sensed at this ECM.
BE3202A4 EPOW_C asserted but one or both PsnEPOWe signals not asserted.
BE3202A5 Loss of power on one power supply - power supply unit (PSU) 1.
BE3202A6 No EPOW signal when power supply removed - power supply unit (PSU) 1.
BE3202A7 False PSnEPOWe signal. PSnEPOWe asserted but power supply reports good - power supply unit (PSU) 1.
BE3202A8 Power Supply removed.
BE3202A9 False indication of power supply removed - power supply unit (PSU) 1.
BE3202AA No EPOW_C when both PsnEPOWe asserted.
BE3202AB False indication of power supply removed - power supply unit (PSU) 2.
BE3202AD Invalid CRC of the primary or backup image.
BE3202AE Invalid CRC of the old image.
BE3202AF Complex Programmable Logic Device (CPLD) error corrected.
BE3202B0 Storage Enclosure Controller Module (ECM) UART test failed.
BE3202B1 UART test failed between storage enclosure controller modules.
BE3202B2 Storage enclosure programmable interface controller UART test failed.
BE3202B3 Voltage sensor test failed.
BE3202B4 Firmware version mismatch between ECMs.
BE3202B5 Power supply unit (PSU) 1, DC under voltage.
BE3202B6 Power supply unit (PSU) 2, DC under voltage.
BE3202B7 Power supply unit (PSU) 1, Over temperature.
BE3202B8 Power supply unit (PSU) 2, Over temperature.
BE3202B9 Power supply unit (PSU) 1, AC fail.
BE3202BA Power supply unit (PSU) 2, AC fail.
BE3202BB Power supply unit (PSU) 1, DC fail.
BE3202BC Power supply unit (PSU) 2, DC fail.
BE3202BD Programmable Interface Controller (PIC) to PIC communication failure.
BE3202BE Configuration settings do not match between ECMs in an enclosure (LIP Enable).
BE3202BF Configuration settings do not match between ECMs in an enclosure (Port Speed).
BE3202C0 Configuration settings do not match between ECMs in an enclosure (Port Type).
BE3202C1 Configuration settings do not match between ECMs in an enclosure (Port Enable).
BE3202C2 Configuration settings do not match between ECMs in an enclosure (Zone Enable).
BE3202C3 Configuration settings do not match between ECMs in an enclosure (Blocking ARB).
BE3202C4 Storage enclosure Fibre Channel interface card has exceeded the threshold for recoverable data transfer Context Full errors.
BE3202C5 Storage enclosure Fibre Channel interface card has exceeded the threshold for recoverable context engine lock Up errors.
BE321100 I2C timeout: Remote SSC200 (processor)
BE321101 I2C timeout: DS1721 (Temperature Sensor)
BE321102 I2C timeout: PCA9552-0 (I/O Expander)
BE321103 I2C timeout: PCA9552-1 (I/O Expander)
BE321104 I2C timeout: PCA9552-2 (I/O Expander)
BE321105 I2C timeout: SOC320 (FC Loop Switch)
BE32110B I2C timeout: PCA9555-2 (I/O Expander on Sense Card, pass-3)
BE321116 I2C timeout: DS1855 (Digipot)
BE321200 GPIO Miscompare: Slot 0 Fault LED
BE321201 GPIO Miscompare: Slot 1 Fault LED
BE321202 GPIO Miscompare: Slot 2 Fault LED
BE321203 GPIO Miscompare: Slot 3 Fault LED
BE321204 GPIO Miscompare: Slot 4 Fault LED
BE321205 GPIO Miscompare: Slot 5 Fault LED
BE321206 GPIO Miscompare: Slot 6 Fault LED
BE321207 GPIO Miscompare: Slot 7 Fault LED
BE321208 GPIO Miscompare: Slot 8 Fault LED
BE321209 GPIO Miscompare: Slot 9 Fault LED
BE32120A GPIO Miscompare: Slot 10 Fault LED
BE32120B GPIO Miscompare: Slot 11 Fault LED
BE32120C GPIO Miscompare: Slot 12 Fault LED
BE32120D GPIO Miscompare: Slot 13 Fault LED
BE32120E GPIO Miscompare: Slot 14 Fault LED
BE32120F GPIO Miscompare: Slot 15 Fault LED
BE321210 GPIO Miscompare: Pack Fault LED
BE321211 GPIO Miscompare: Partner Card Fault LED
BE321212 GPIO Miscompare: SOC320 Reset A
BE321213 GPIO Miscompare: Sense Card I2C Reset
BE321214 GPIO Miscompare: Sense Card Identity
BE321215 GPIO Miscompare: Local Card Fault LED
BE321216 GPIO Miscompare: Connector 3 LED
BE321217 GPIO Miscompare: Connector 2 LED
BE321218 GPIO Miscompare: Connector 1 LED
BE321219 GPIO Miscompare: Connector 0 LED
BE32121A GPIO Miscompare: Drive Address Buffer Enable
BE32121B GPIO Miscompare: Expander I2C Reset
BE32121C GPIO Miscompare: SOC320 Reset B
BE32121D GPIO Miscompare: Watchdog Timer Reset
BE321302 GPIO Miscompare: Sense Card LED
BE321305 GPIO Miscompare: Sense Card Over Temp Notify
BE321310 Flash Write Failure
BE321311 Flash Erase Failure
BE321312 VPD Write Failure Ras
BE321313 VPD Erase Failure
BE321314 SES has taken an internal statesave
BE321315 SES has detected an internal hardware error
BE321316 FCIC detected problem with FCIC Location Signal - left FCIC Card
BE321317 FCIC detected problem with FCIC Location Signal - right FCIC Card
BE321318 Unexpected amount of self-initiated FCIC Card reboots occurred.
BE321319 EPOW Signal from PPS1 (cpPPSr0, r=rack)
BE32131A EPOW Signal from PPS2 (cpPPSr1, r=rack)
BE32131B Storage enclosure reporting 12V Under Voltage.
BE32131C Storage enclosure reporting 12V Over Voltage.
BE32131D Storage enclosures reporting 5V Under Voltage.
BE32131E Storage enclosures reporting 5V Over Voltage.
BE322001 PTBI Error
BE322002 Fibre Channel Cable Failure
BE322003 Fibre Channel Cable Failure
BE322101 Port Test Before Insert (PTBI) failure.
BE322104 CRC error.
BE322105 SEOC passes and PTBI fails.
BE322106 Serial Number Exchange On Connect (SEOC) failure.
BE322108 Loss of signal detected.
BE322109 Storage enclosure is incorrectly cabled. Connecting one enclosure to more than two other enclosures.
BE32210A Internal SerDes error.
BE32210B SFP present but unable to read VPD.
BE32210C SAS protocol attempted.
BE32210D Port bypassed.
BE32210F Transmit (TX) fault detected.
BE322110 Port (DDM or SFP) removed.
BE322111 Loss of sync.
BE322112 Comma character timeout.
BE322113 Wrong speed attempted - Port not running at set speed.
BE322114 Unknown ordered set.
BE322115 Clock accuracy (PPM) out of spec.
BE322116 Checksum/read failure on SFP VPD.
BE322117 Invalid received word (Rx).
BE322118 Multiple connection stall timeouts.
BE322119 Reception of loop initialization primitive (F8, xx).
BE32211A Reception of directed loop initialization primitive.
BE32211C Arbitrated loop physical address (ALPA) claimed multiple times.
BE32211D Loop initialization timeout (LIxA).
BE32211E Loop initialization timeout (LISM).
BE322125 Unexpected Open received.
BE322126 Reflected Open.
BE32212A Storage enclosure is incorrectly cabled. Crossed A and B sides within one loop of enclosures.
BE322130 SFP temperature high.
BE322131 SFP voltage (Vcc) high.
BE322132 SFP voltage (Vcc) low.
BE322133 Measured SFP Transmit (Tx) bias exceeds high value.
BE322134 Measured SFP Transmit (Tx) bias below low value.
BE322135 Measured SFP Receive (Rx) power exceeds high value.
BE322136 Measured SFP Receive (Rx) power below low value.
BE322137 DDM not seated properly.
BE322138 Phy (SerDes) Controller (PHYC) Failure.
BE322139 Data word sync reset.
BE32213A Phy (SerDes) Controller (PHYC) layer reset.
BE32213D OPEN Rejects - Command, Task, Data.
BE32213F OPEN Timeout - Command, Task, Data.
BE322141 Multiple DONE or CLOSE timeouts.
BE322142 BREAK timeout.
BE322143 BREAK received in response to OPEN Address Frame - Command, Task, Data.
BE322145 BREAK received after connection established but before ACK/NAK balance - Command, Task, Data.
BE322147 BREAK received after connection established and after ACK/NAK balance.
BE322148 Enhanced Port Test Before Insert (EPTBI) Failed.
BE322149 No acknowledgement (NAK) received - Command, Task, Data.
BE32214A No acknowledgement (NAK) received by DDM.
BE32214B Acknowledgement (ACK/NAK) timeout - Command, Task, Data.
BE32214D Credit timeout - Command, Task, Data.
BE32214F Primitive Error (no K character or invalid 8/10b encoding).
BE322150 Unknown primitive.
BE32215B OPEN Address Frame to initiator not logged in on Fibre Channel.
BE32215C OPEN Address Frame with unsupported protocol, connection rate, or wrong destination.
BE32215D OPEN Address Frame with: errors detected.
BE32215E IDENTIFY or Open Address Frame with errors detected.
BE322164 Switch on a chip (SOC) taken offline.
BE322166 SAS Port set to Fibre Channel Mode.
BE322167 SAS Port set to force bypass.
BE327000 Storage enclosure power supply repair has detected a communication failure between the ICs and PSU.
BE327001 AC fail has been detected on a storage enclosure power supply and the PSU or PDU was isolated.
BE327002 AC fail has been detected on one or more storage enclosure power supplies and root cause could not be isolated.
BE327003 DC over voltage condition has been detected on a storage enclosure power supply.
BE327004 DC under voltage condition has been detected on a storage enclosure power supply.
BE327005 DC fail voltage condition has been detected on a storage enclosure power supply.
BE327006 Storage enclosure power supply has detected a fault condition.
BE327007 Storage enclosure power supply has detected an over temperature condition.
BE327009 Storage enclosure interface card(s) have detected a storage enclosure power supply is installed but with failures.
BE327010 Storage enclosure interface card(s) have detected a storage enclosure power supply is not installed.
BE327011 Storage enclosure interface card(s) have detected a storage enclosure power supply with unexpected status.
BE327012 Storage enclosure power supply has detected BOTH ICs missing (this could be a false error or issue with power supply).
BE327013 Storage enclosure interface card(s) have detected EPOW condition with one or more power supplies.
BE327014 Storage enclosure interface card(s) have detected EPOW condition, but the condition cannot be fully isolated.
BE327015 Storage enclosure FCIC card(s) requested storage enclosure power supplies to power off.
BE327016 One or more storage enclosure interface card(s) have signaled the storage enclosure power supplies to power off, but a status conflict is detected.
BE327017 Storage enclosure interface card(s) have detected the storage enclosure power supply asserting alert status.
BE327018 Storage enclosure interface card(s) have detected the storage enclosure power supply asserting alert status, but the power supply does not report the same status.
BE327019 Storage enclosure power supply verification has detected the storage enclosure power supply fans have not returned to normal after the service action.
BE327020 Storage enclosure power supply firmware download has failed for unknown reason, but no faults were detected on installed power supply.
BE327021 Storage enclosure power supply verification was unable to verify the status of the partner power supply so did not continue with firmware update.
BE327022 Storage enclosure power supply verification was unable to discover associated enclosure and cannot continue (possible both power supplies do not have power or do not function).
BE32CEA0 Unexpected storage enclosure error code detected.
BE32CEF0 Unexpected storage enclosure error code detected.
Table 4. BE33xxxx system reference codes
System reference code Description
BE330000 Unknown Exception Symptom Code.
BE33CE00 DA Hardware Error: Fatal Error.
BE33CE01 DA Hardware Error: Bad INIT Command Error.
BE33CE02 DA Hardware Error: Bad Download Command Error.
BE33CE03 DA Hardware Error: Restart State.
BE33CE04 DA Hardware Error: Dead State.
BE33CE05 DA Hardware Error: Ping TO With Adapter Error.
BE33CE06 DA Hardware Error: Ping TO With NO Adapter Error.
BE33CE07 DA Hardware Error: Quiesce Timeout.
BE33CE08 DA Hardware Error: Reset Complete Failed.
BE33CE09 DA Hardware Error: Gateway Disconnect Failed.
BE33CE0A DA Hardware Error: Reset 64 Failed.
BE33CE0B DA Hardware Error: Reset INIT Failed.
BE33CE0C DA Hardware Error: Download Reset Complete Failed.
BE33CE0D DA Hardware Error: Download 64 Failed.
BE33CE0E DA Hardware Error; Download DNLD Failed.
BE33CE0F DA Hardware Error: Terminate Reset Complete Failed.
BE33CE10 DA Hardware Error: Showstop Timeout.
BE33CE11 DA Hardware Error: Device Adapter VPD Timeout.
BE33CE12 DA Hardware Error: Ping TO With Adapter Error on last path to data.
BE33CE13 DA Hardware Error: Exceeded maximum allowed DAs.
BE33CE14 DA Hardware Error: DA_4460_NVRAM_FAILURE.
BE33CE15 DA Hardware Error: DA_4461_NVRAM_CORRECT_FAILURE.
BE33CE16 DA Hardware Error: DA_4471_CSSINGLE_BITERR.
BE33CE17 DA Hardware Error: DA_4472_SDRAM_SINGLEBIT_ERR.
BE33CE18 DA Hardware Error: Device Adapter DMA push invalid known pattern.
BE33CE19 DA Hardware Error: Device Adapter DMA push invalid address.
BE33CE1A DA Hardware Error: The FCAL network is not stable enough for RAID to progress.
BE33CE1B DA Hardware Error: Internal error in the ARC firmware.
BE33CE1C DA Hardware Error: Bad SY_Code.
BE33CE1D DA Hardware Error: DPB_Number too high.
BE33CE1E DA Hardware Error: Illegal DP_Pending.
BE33CE1F DA Hardware Error: Directive returned; DP_aborting.
BE33CE20 DA Hardware Error: Showstop error happened.
BE33CE21 DA Hardware Error: DPB has wrong safety value in Knl_CompleteDirective.
BE33CE22 DA Hardware Error: Idsb != DP_Pending to DP_Aborting in Knl_CompleteDirective.
BE33CE23 DA Hardware Error: Den_default called.
BE33CE24 DA Hardware Error: Dab_default called.
BE33CE25 DA Hardware Error: Bad period in Den_NoOperation.
BE33CE26 DA Hardware Error: Bad flag value in Dab_NoOperation.
BE33CE27 DA Hardware Error: DP_Pending in Den_AbortDirective2.
BE33CE28 DA Hardware Error: DP_Aborting returned from abort routine.
BE33CE29 DA Hardware Error: DefaultIsr called.
BE33CE2A DA Hardware Error: Number too large in Knl_ProcessInterupt.
BE33CE2B DA Hardware Error: Zero time in clock block.
BE33CE2C DA Hardware Error: Thread routine called with CTask == 0.
BE33CE2D DA Hardware Error: Knl_RoundRobin called with F/G task.
BE33CE2E DA Hardware Error: DC_ExitThread without SY_None.
BE33CE2F DA Hardware Error: Thread routine called without thread support.
BE33CE30 DA Hardware Error: Den_AllowcateBytes > D__MAXMALLOC.
BE33CE31 DA Hardware Error: Malloc failure.
BE33CE32 DA Hardware Error: Corrupt MCB_DestinationNode in Dab_startTranssaction.
BE33CE33 DA Hardware Error: Knl_CompleteMcbDirective not called with MCB.
BE33CE34 DA Hardware Error: sop->SOP_Tcb == 0 in DC_SlavdOperation.
BE33CE35 DA Hardware Error: TCB_SlaveOperationEntryPoint == 0 in Den_SlaveOperation.
BE33CE36 DA Hardware Error: No default service.
BE33CE37 DA Hardware Error: Strange error from DC_Allocate bytes.
BE33CE38 DA Hardware Error: Strange error from DC_Free bytes.
BE33CE39 DA Hardware Error: Directive failure.
BE33CE3A DA Hardware Error: Lst function: qh == 0.
BE33CE3B DA Hardware Error: Lst function: ve == 0.
BE33CE3C DA Hardware Error: Que function: qh == 0.
BE33CE3D DA Hardware Error: Que function: ve == 0.
BE33CE3E DA Hardware Error: No background thread support.
BE33CE3F DA Hardware Error: TCB not active in ipng00.
BE33CE40 DA Microcode Error: First Reset.
BE33CE41 DA Microcode Error: Open Restart.
BE33CE42 DA Microcode Error: Reset Locked.
BE33CE43 DA Microcode Error: GF Reset Adapter.
BE33CE44 DA Microcode Error: Gateway Disconnect.
BE33CE45 DA Microcode Error: Download Start.
BE33CE46 DA Microcode Error: ISSDS Reset.
BE33CE47 DA Microcode Error: Warmstart Force.
BE33CE48 DA Microcode Error: Warmstart No Skip.
BE33CE49 DA Microcode Error: Download Successful.
BE33CE4A DA Microcode Error: Partner Disconnect.
BE33CE4B DA Microcode Error: Heartbeat Invalid.
BE33CE4C DA Microcode Error: Inbound Queue 1.
BE33CE4D DA Microcode Error: Inbound Queue 2.
BE33CE4E DA Microcode Error: Reply Unexpected.
BE33CE4F DA Microcode Error: TCB Start Slave Failed.
BE33CE50 DA Microcode Error: MCB Fail Start.
BE33CE51 DA Microcode Error: Fail Send Ping.
BE33CE52 DA Microcode Error: IOCTL Timeout.
BE33CE53 DA Microcode Error: Dead State No Fence.
BE33CE54 DA Microcode Error: IRQ Read Failed.
BE33CE55 DA Microcode Error: EEH Recovery Failed.
BE33CE56 DA Microcode Error: TCB Start Init Failed.
BE33CE57 DA Microcode Error: TCB Start DNLD Failed.
BE33CE58 DA Microcode Error: Dump Failed.
BE33CE59 DA Microcode Error: DA Failover/Failback.
BE33CE5A DA Microcode Error: DA Requested Reset.
BE33CE5B DA Microcode Error: DA No Data in EIR.
BE33CE5C DA Microcode Error: DA Informational Event.
BE33CE5D DA Microcode Error: DA Unknown Error.
BE33CE5E DA Microcode Error: Device Adapter Requested Reset.
BE33CE5F DA Microcode Error: DA Fence due to Fabric.
BE33CE60 DA Microcode Error: DA Error in Fabric.
BE33CE61 DA Microcode Error: DA/Fabric Error in Fabric.
BE33CE62 DA Microcode Error: DA Requested Reset.
BE33CE63 DA Microcode Error: DA Informational Error.
BE33CE64 DA Microcode Error: DA No Data in EIR.
BE33CE65 DA Microcode Error: Unknown DA Error.
BE33CE66 DA Microcode Error: Device Adapter Requested Reset.
BE33CE67 DA Microcode Error: DA Send Mail Failure.
BE33CE68 DA Microcode Error: BAD LRC ON EIR.
BE33CE69 DA Microcode Error: Drive Dumps Available.
BE33CE6A DA Microcode Error: IOCTL Failure.
BE33CE6B DA Microcode Error: DA Favored Cache LRC.
BE33CE6C DA Microcode Error: Config Failure.
BE33CE6D DA Microcode Error: Global Data Establish Error.
BE33CE6E DA Microcode Error: Global Data Error Recovery Fence Remote.
BE33CE70 DA Rank Failover/Failback Occurred.
BE33CE71 DA Rank Layout Error.
BE33CE72 Unknown Rank Error.
BE33CE73 DDM Reconstruct Read Occurred.
BE33CE76 Logical Disk Failure.
BE33CE7B One or more logical volumes or repositories has entered into a failed state.
BE33CE7E Device adapter card(s) reported that a storage enclosure DDM failed the secure data overwrite process.
BE33CE84 Device adapter microcode error: Sequence number error (Real).
BE33CE85 Device adapter microcode error: Sequence number error (False).
BE33CE88 Device adapter microcode error: Datapath Error (Real).
BE33CE89 Device adapter microcode error: Datapath Error (False).
BE33CE8C Device adapter microcode error: Data parity (LRC error) error detected.
BE33CE8F Device adapter microcode error: Data parity error (LRC error) detected during generation of data parity (Real).
BE33CE90 Device adapter microcode error: Data parity error (LRC error) detected during generation of data parity (False).
BE33CE94 Device adapter microcode error: Physical address check (Real) due to an R0 Metadata mismatch.
BE33CE9B Device adapter datapath error: Loss of access occurred. Corrective action attempted against last available device adapter of a device adapter pair.
BE33CE9C Device adapter datapath error: Temporary loss of access occurred. Corrective action taken against last available device adapter of a device adapter pair.
BE33CEA8 Device adapter card has encountered a fatal error and has requested a reset.
BE33CEC6 Device adapter microcode error: Loss of access to global data.
BE33CEC8 Device adapter microcode error: PCI configuration write failure.
BE33CEC9 Device adapter microcode error: PCI configuration read failure.
BE33CED1 Device adapter microcode error: Lost heartbeat with partner adapter.
BE33CED4 Device adapter in service mode was fenced due to a service action interrupted by a warmstart.
BE33CED6 Easy Tier volume migration error: migration timeout.
BE33CED8 Informational Message - Customer only notification of rank transitioning into rank rebuild.
BE33CED9 Informational Message - Customer only notification of rank transitioning out of rank rebuild.
BE33CEDB Device adapter resume failed due to warmstart.
BE33CEDE Timeout waiting for remote server to complete stage error recovery.
BE33CEDF Invalid I/O request command to device adapter.
BE33CEE3 Informational Message - Customer only notification that extended disk recovery occurred. System performance may have been impacted.
BE33CFE4 RAID-6 APU protocol error.
Table 5. BE34xxxx system reference codes
System reference code Description
BE340000 Adapter spares or members do not match program expectation.
BE340001 Device adapter cabling error.
BE340002 Fan tray installed but encountered problems or is not installed.
BE340003 Storage enclosure FCAL cabling error detected.
BE340004 Storage Enclosure: at least one DDM missing in slots 1-8.
BE340005 Storage Enclosure: at least one slot is empty (no DDMs or baffles) in slots 9-16.
BE340006 FCAL Cable: Cabling error detected.
BE340007 Fan sense card in unknown state.
BE340008 FCAL cable not connected on the target loop.
BE340009 LPAR device area resource manager detected unexpected objects during IML harvest that have not yet been installed.
BE34000B Actual RPM less than required RPM and/or actual capacity less than required capacity.
BE34000C Duplicate IBM.EssStorageEnclosure objects found.
BE34000D The harvested attribute values for the component are not consistent with the attributes on the associated RM object model.
BE34000E Logical configuration error.
BE34000F DDM certify operation could not be completed due to multiple device adapter resets.
BE340010 Device Area Resource Manager detected objects harvested by the Group Leader Node but not the Peer Node or attribute mismatch between Group Leader and Peer harvested attributes.
BE340011 Device Area Resource Manager detected objects harvested by the Peer Node but not the Group Leader Node.
BE340012 Device Area Resource Manager detected objects missing in the current harvest.
BE340013 Rejected drive found during health check.
BE340014 Bypassed drive found during health check.
BE340015 A POST error was reported.
BE340016 DDM object mismatch detected.
BE340017 Device adapter invalid or corrupt VPD data detected.
BE340018 One or more bypassed drives detected in a storage enclosure.
BE340019 Failed to get device information from Resource Manager.
BE34001A Device adapter cannot see SES disk(s).
BE34001B DDM resume failure.
BE34001C Call home for previously deferred service.
BE34001D Duplicate physicalId (Rx-Syz) detected in ODM.
BE34001E Invalid physical location ID detected in ODM, but a valid physical location ID is reflected in the device area resource manager object model.
BE34001F DDM format complete but initsurf_valid bit not set.
BE340020 Invalid pdisk name detected.
BE340021 Device object mismatch detected in RM object(s).
BE340022 Health check detected a drive with an unknown use.
BE340023 Disk use is invalid.
BE340024 DDM migration failed.
BE340025 Failed drives found during health check.
BE340026 Health check attempted to fail a rejected, bypassed, or unknown DDM, but was unable to determine the locationCode. The DDM may not be fully installed or the DDM object may be missing.
BE340027 Service action detected a bypassed or empty DDM slot and was unable to return it to normal use.
BE340028 Empty slot found by device health check for installed drive not in service.
BE340029 Install or repair detected FCIC or Backplane VPD incoherence.
BE34002A Adapter is not available.
BE34002B Failed to initiate sparing because the dual loop does not contain any valid spares.
BE34002C Sparing operation failed due to microcode error.
BE34002D Sparing was not initiated due to incorrect array state. Array could be in rebuilding or unknown state.
BE34002E Failed to update LPAR device area resource manager. (Possible attribute value mismatch.)
BE34002F LPAR device area resource manager attribute value mismatch detected.
BE340030 Detected a powered-off slot in the I/O tower.
BE340031 LPAR microcode failed to discover device adapter card.
BE340032 LPAR microcode unable to set device adapter card in service mode.
BE340033 LPAR microcode unable to reset device adapter card service mode.
BE340034 Service action detected a non-operational LPAR.
BE340035 DDM firmware update failed due to a system error.
BE340036 Unrecoverable error occurred while updating FCIC card or PSU firmware.
BE340037 Device adapter memory flash card has failed or reached end of life. (Microcode reported error codes are 4060, 4062, or 4063.)
BE340038 Device adapter card has a broken ISP. (Microcode reported error code is 40A0.)
BE340039 Device adapter card detected illegal loop configuration. (Microcode reported error code is 40A4.)
BE34003A Different device adapters types detected on each loop. (Microcode reported error code is 40D0.)
BE34003B Device adapter card detected an unused loop. (Microcode reported error code is 40D4.)
BE34003C Device adapter card detected an unused FC chip. (Microcode reported error code is 40D8.)
BE34003D Device adapter card failed diagnostics.
BE34003E Device adapter card is unavailable and could be fenced or in service mode.
BE34003F Health check detected a device adapter card in service mode for more than 72 hours. Performance may be impacted.
BE340040 Health check found fenced adapter.
BE340041 SES utility reported communication error.
BE340042 The storage enclosure installation process failed to discover at least one enclosure.
BE340043 Dual loop imbalance detected.
BE340044 Service action detected one or more missing Rack ODM object(s).
BE340045 All storage enclosures have duplicate physical IDs (Rx-Syz) and/or have PackID values greater than 5.
BE340046 Duplicate storage enclosure physical IDs (Rx-Syz) detected and at least one enclosure reports good Pack ID.
BE340047 Duplicate storage enclosure physical IDs (Rx-Syz) and/or bad PackID (greater than 5) detected.
BE340048 LPAR microcode failed to configure the device adapter card during a repair or install service action.
BE340049 cpss0 is unavailable.
BE34004A Storage enclosure service action encountered an error while querying ODM.
BE34004B Storage enclosure install failed to enable/disable downstream FCIC card port.
BE34004C The storage enclosure installation process detected a loop error.
BE34004D The storage enclosure installation process detected an invalid drive count. This could be due to missing and/or bypassed drives.
BE34004E The storage enclosure installation process detected at least one downstream trunk cabling error.
BE34004F An error occurred while configuring enclosures and its drives.
BE340050 Device RM or IBM.essSADevicesRM is inactive.
BE340051 The system state is inappropriate for code load. At least one device error count has exceeded its threshold.
BE340052 Failed to format or resume drive because diskCapacity and RPM are invalid.
BE340053 The storage enclosure configuration process detected at least one enclosure with inconsistent FCIC VPDs. The inconsistency could be the result of mismatched VPDs between FCIC cards in the enclosure.
BE340054 Drive was marked for deferred sparing.
BE340055 Start of changeDisk class, capacity, or RPM intermix within a storage enclosure or between a storage enclosure pair.End of change
BE340057 DDM configuration process failed to configure the DDM.
BE340058 Storage enclosure service action detected missing rack ODM object.
BE340059 Detected all storage enclosures with a duplicate physical ID (Rx-Syz). This error can occur due to hung I2C bus.
BE34005A Detected storage enclosures with a duplicate physical ID (Rx-Sxy) and a good pack ID. This error can occur due to hung I2C bus.
BE34005B Detected storage enclosures with duplicate physicalIDs (Rx-Sxy), bad pack IDs, or both. This error could be related to improperly seated enclosure cables that are connected to the fan sense card.
BE34005C LPAR unable to query device adapter resource status during service action.
BE34005D Device adapter service action failed to enable all on-board ports.
BE34005E Storage enclosure code update cannot continue because the DDMs that communicate to FCIC card are unavailable.
BE34005F The storage enclosure installation process detected one or more pre-existing RAID array members.
BE340060 Service action detected a single drive single port active (not present on one loop of the dualLoop). Normally this indicates a problem with the DDM or FCIC.
BE340061 Service action detected a single drive with a disused port (one drive port has been logically bypassed by the adapter). Normally this indicates a problem with the DDM or FCIC.
BE340062 issdiag returned SRC indicating DDM is bad and needs to be replaced.
BE340063 Drive failed diagnostics test.
BE340064 Device Adapter's owning PCI slot is not powered off.
BE340065 Device Adapter's owning PCI slot power status could not be obtained- RTAS call failed or PCI slot is missing from device tree.
BE340065 Device Adapter's owning PCI slot power status could not be obtained- RTAS call failed or PCI slot is missing from device tree.
BE340066 SE install detected an invalid rackID, packLevel, FCIC device, or connector value from the downstream FCIC. The downstream FCIC is included in the FRU list and has location code of the form Rx-Syz-P1-Ca. Reseat this FCIC card and make sure the cabling from this FCIC to the upstream enclosure is also properly seated. Close this service event and attempt install again. If install fails again, either replace the card or call next level of support.
BE340067 FCIC repair or storage enclosure install detected an internal error while updating FCIC firmware. Call the next level of support.
BE340068 FCIC repair or storage enclosure install detected a device adapter not in good state while updating FCIC firmware. Replace FCIC and retry service action.
BE340069 FCIC repair or storage enclosure install failed while downloading FCIC firmware. Replace FCIC and retry service action.
BE34006A FCIC repair or storage enclosure install detected a missing firmware binary. Call next level of support.
BE34006B FCIC repair or storage enclosure install failed during firmware update while calling issraid. Retry service action without replacing parts.
BE34006C FCIC card repair or the storage enclosure installation process failed during firmware download because one or more RAID arrays are not in good state. At least one RAID array may still be rebuilding.
BE34006D FCIC card repair or the storage enclosure installation process failed because one or more FCAL loops are not in good state.
BE34006E FCIC card repair or storage enclosure installation process failed to set FCAL loop in service mode.
BE34006F FCIC card repair or the storage enclosure installation process failed to reset FCAL loop out of service mode.
BE340070 FCIC card firmware download completed successfully, but additional problems were detected.
BE340071 The storage enclosure installation process failed to set FCAL loop in service mode during firmware update. Firmware download has not yet started.
BE340072 FCIC card repair or the storage enclosure installation process detected a storage enclosure in Defined state.
BE340073 DDM could not be deconfigured during sparing operation due to internal microcode error.
BE340074 DDM could not be deconfigured because no spares were available.
BE340075 DDM could not be deconfigured due to a special data situation.
BE340076 DDM could not be deconfigured after multiple retries because device adapter card was reset.
BE340077 Microcode failed to unfence device adapter card during device adapter installation process.
BE340078 Storage enclosure installation process detected a DDM missing from ODM.
BE340079 Storage enclosure installation process detected a DDM bypassed in a storage enclosure on the same FCAL loop.
BE340080 SE install detected at least one bypassed drive on the newly installed enclosure.
BE340082 Storage enclosure installation process failed due to incorrect rackID value detected during FCAL cable check.
BE340083 Storage enclosure installation process failed due to incorrect rackID and packLevel detected during FCAL cable check.
BE340084 This service action cannot proceed until an error on the partner FCAL loop is repaired.
BE340085 FCIC card or FCAL cable replacement failed due to FCAL loop error.
BE340086 FC-AL cable check detected cable problem at a device adapter card.
BE340087 Cable check detected less than two FC-AL loops in Good state. This could be the result of split network condition. There may be a problem with cabling.
BE340088 FC-AL Cable check detected split network condition. There may be a problem with cabling.
BE340089 Service action failed because storage enclosure FCAL loop cross cabling was detected (half of dual loop 1).
BE34008A Service action failed because storage enclosure FCAL loop cross cabling was detected (half of dual loop 2).
BE34008B Service action failed because storage enclosure FCAL loop cross cabling across loops was detected (across dual loops).
BE34008C DA repair was successful but FC-AL cable check detected partner device adapter not seen on the loop.
BE34008D FC-AL cable check found blank output from issmap when enclosures are installed on the daPair.
BE34008E Device adapter card service action did not run FCAL loop checking because repair was run on non-owning LPAR.
BE34008F Device adapter card repair detected an unknown dormant compact flash data.
BE340090 Owning device adapter card was unable to gain access to the DDM to perform diagnostics during storage enclosure install verification process.
BE340091 An unexpected storage enclosure was detected during storage enclosure installation process.
BE340092 Service action failed because both LPARs are not IMLed (cpss0 not available).
BE340093 Service action failed because one of the device adapter cards in a device adapter pair is not available.
BE340094 FCIC card harvest detected invalid FCIC card VPD.
BE340095 Service action has failed because device area resource manager was not operational on both LPARs.
BE340096 The storage enclosure has the invalid rackNumber R16 or R15. The PPS may not be correctly programming the sense card.
BE340097 Storage enclosure has invalid physical ID (Rx-Syz).
BE340098 Error occurred while updating FCIC firmware because SES disks were unavailable or formatting. Try again at a later time.
BE340099 DDM repair failed because the drive is bypassed by the FCIC card microcode.
BE34009A FCAL cable check detected cross connected cables at device adapter card.
BE34009B FCAL cable check detected cross connected cables at an FCIC card.
BE34009C Multiple DDMs are reporting over-temperature alert. Customer room temperature may be greater than 32 degrees C (90 degrees F).
BE34009D DA repair could not verify cabling
BE34009E FDE drive is not cryptographically erased. isscryptoerase utility failed due to software or hardware error.
BE34009F One or more FDE drives are not cryptographically erased.
BE3400A0 DDM Reported Error: Disk class mismatch detected.
BE3400A1 LPAR device area resource manager detected an exception while updating database (system registry) during harvest operation. Database is likely out of sync between LPARs.
BE3400A2 Failed to enroll FDE drive. Encryption groupId is inaccessible.
BE3400A3 Cryptographic erase was not initiated because target drive listed as member or spare. Drive must be in unconfigured state before attempting this action.
BE3400A4 Device adapter card service action failed to reset DA takeover condition in single LPAR operational mode.
BE3400A5 Device adapter card service action failed to reset DA takeover condition in dual LPAR operational mode.
BE3400A6 Service action failed to determine the DDM disk class possibly due to faulty DDM firmware.
BE3400A7 Service action detected a DDM disk class intermix within storage enclosure slot group.
BE3400A8 Service action detected partner storage enclosures with unequal DDM counts.
BE3400A9 Repair detected partner device adapter with one or more FC-AL loops not in Good state so did not verify cabling for partner device adapter.
BE3400AA DDM format operation failed.
BE3400AB The storage enclosure installation process detected at least one FCAL loop error.
BE3400AC Service action detected an intermix of SSD and non-SSD DDMs.
BE3400AD Service action detected an invalid SSD DDM count within a device adapter pair.
BE3400AE Service action detected an intermix of encryption and non-encryption capable DDMs within a storage enclosure slot group.
BE3400AF Service action detected an intermix of encryption and non-encryption capable DDMs within a device adapter pair.
BE3400B0 FCIC card repair detected one or more needed DDMs are unavailable.
BE3400B1 FCIC card repair detected that all needed DDMs are unavailable.
BE3400B2 FCIC repair detected native SES/ESI DDMs are unavailable.
BE3400B3 One or more DDM's are in Security Degraded condition.
BE3400B4 One or more DDMs are in Hard Security Degraded condition.
BE3400B5 DDM install failed because unexpected DDM(s) or slot status was found for storage enclosure slots not being installed.
BE3400B6 Configured encryption group is inaccessible.
BE3400B7 Cannot continue with service action. Replacement drive is a member of an array.
BE3400B8 daDeconfigCryptoEraseFdeDisk utility failed. Disk could not be deconfigured and/or cryptographically erased.
BE3400B9 DA type mismatch detected.
BE3400BA FDE drive could not be cryptographically erased due to internal microcode error.
BE3400BB FDE drive could not be resumed because encryption group state could not be determined.
BE3400BC Detected an invalid DDM capacity.
BE3400BD More than one DDM drive has failed during format or certify.
BE3400BE A failed DDM drive whose state is 9 or 10 was detected during the format or cryptographic erase of arraySite.
BE3400BF issmap/issses command failed during FC-AL cable check.
BE3400C0 Unexpected DDM found in storage enclosure drive slot.
BE3400C1 Storage enclosure repair verification process detected that one or more storage enclosure FRUs were not installed in original locations.
BE3400C2 Storage enclosure backplane repair sys lev verify: cmd issses_checkpost failed after resetting both FCICs.
BE3400C3 At least one storage enclosure component is in bad state.
BE3400C4 DDM SysLevVer, the replacement drive is single port active.
BE3400C5 DDM SysLevVer, the left port for multiple drives are NOT active.
BE3400C6 DDM verification process detected that one of the two ports for multiple DDMs is not available.
BE3400C7 Storage Enclosure: At least one DDM missing in slots 17-24.
BE3400C8 Storage enclosure midplane repair detected an invalid storage enclosure WWNN.
BE3400C9 The service action could not recover an IC port in bad state. This could be due to a bad port or a miscabling.
BE3400CA DDM has exceeded media error thresholds and was failed after a successful smart rebuild with a spare DDM.
BE3400CB DDM has exceeded background media scan threshold (flagged by DA process).
BE3400D0 Midplane System Level Verify: some fields in VPD are not valid.
BE3400D1 The storage installation process failed due to an unsupported DDM intermix condition.
BE3400F3 Device adapter repair failed, service action failed to reset disabled resources on partner adapter.
BE3400F6 The storage enclosure installation process detected a member drive that belongs to a legitimate RAID array.
BE340106 The service action failed to deactivate the target FRU.
Start of changeBE340113End of change Start of changeLPAR health check is not running as frequently as expected.End of change
BE344440 Storage enclosure has a single port active.
BE346018 Proactive slow disk notification.
BE34CA11 Problem Analysis could not completely diagnose a Device Area failure. A FRU was not isolated. System state saves have been forced.
BE34CE12 Bypassed and failed a drive based on 0xCE12 invocation and error threshold count (attempt to bypass a drive before it fences alt DA).
Table 6. BE35xxxx system reference codes
System reference code Description
BE35250D An EEH Event On This IOA Slot Has Been Detected
BE35250E EEH Event Caused by IOA Asserting SERR
BE35250F EEH Event Caused by Host MMIO RAM Error
BE352510 EEH Event Caused by EadsX Detecting Bad Parity on PHB
BE352511 EEH Event Caused by EadsX Detecting Bad Parity on IOA bus
BE352512 EEH Event Caused by EadsX Master Aborted by PHB
BE352513 EEH Event Caused by EadsX Master Aborted by IOA
BE352514 EEH Event Caused by EadsX Target Aborted by PHB
BE352515 EEH Event Caused by EadsX Target Aborted by IOA
BE352516 EEH Event Caused by EadsX Destination Bus Was Reset
BE352517 EEH Event Caused by EadsX Detecting Bad Write Data Parity on PHB bus
BE352518 EEH Event Caused by EadsX Detecting Bad Write Data Parity on IOA bus
BE352519 EEH Event Caused by EadsX Discarding Delayed Completion Operation because IOA Did Not Retry the Operation in Time
BE35251A EEH Event Caused by EadsX Discarding Delayed Completion Operation because PHB Did Not Retry the Operation in Time
BE35251B EEH Event Caused by an EadsX Master Bus Timeout on IOA Bus
BE35251C EEH Event Caused by an EadsX Time Out Waiting for PHB to Return Split Completion Operation
BE35251D EEH Event Caused by an EadsX Time Out Waiting for IOA to Return Split Completion Operation
BE35251E EEH Event Caused by EadsX Received Split Completion Message From PHB
BE35251F EEH Event Caused by EadsX Received Split Completion Message From IOA
BE352520 EEH Event Caused by EadsX Received Master/Target Abort From PHB When It tried to return a Split Completion.
BE352521 EEH Event Caused by EadsX Received Master/Target Abort From IOA Or IOA Bus Was Reset When EadsX tried to return a Split Completion.
BE352522 EEH event was caused by EadsX entering freeze state for an unknown reason.
BE352600 Host Adapter Error During Service Mode
BE352601 Host Adapter Interrupt With NO DATA Error
BE352602 Host Adapter EIR LRC Check
BE352603 Host Adapter Message LRC Failure
BE352604 Host Adapter Invalid Message Failure
BE352605 Host Adapter Control Message Failure
BE352606 Host Adapter Data CRC Check
BE352607 Host Adapter Data CRC Check and Cache Check
BE352608 Host Adapter Data LRC Check
BE352609 Host Adapter Data LRC Check and Cache Check
BE35260A Host Adapter SCSI SeqNum Error First Event
BE35260B Host Adapter SCSI SeqNum Error and Cache LRC
BE35260C Second occurrence of customer data sequence number error
BE35260D Host Adapter Header LRC Check
BE35260E Host Adapter Header LRC Check and Cache Check
BE35260F Host Adapter Header PA bad CRC
BE352610 Host Adapter Header PA bad CRC and Cache Check
BE352611 Second occurrence of customer data physical address error
BE352612 Host Adapter Error: Invalid Record Sector
BE352613 Host Adapter Error: Invalid Record Sector and Cache Check
BE352614 Host Adapter: SCSI Abort Task
BE352615 Host Adapter: SCSI Abort Task Set
BE352616 Host Adapter: SCSI Clear Task Set
BE352617 Host Adapter: SCSI LUN Reset
BE352618 Host Adapter: SCSI Target Reset
BE352619 Host Adapter HA Trace Log
BE35261A Host Adapter HA Abort Log Reported
BE35261B Host Adapter HA Logical Table Mismatch
BE35261C Host Adapter Host Log: Abort Task
BE35261D Host Adapter Host Log: Check Condition
BE35261E Host Adapter Host Logging Enabled
BE35261F Host Adapter Host Logging Disabled
BE352620 Host Adapter Host Log: Task Timeout
BE352621 Host Adapter Fixed Block MLE
BE352622 Host Adapter Adapter Error: Panic
BE352623 Host Adapter ODM Failure - cpss0 CuDv
BE352624 Host Adapter ODM Failure - odmget CuDv parent
BE352625 Host Adapter ODM Failure - CuDv bad state
BE352626 Host Adapter ODM Failure - CuDv odmget
BE352627 Host Adapter ODM Failure - no CuDv
BE352628 Host Adapter ODM Failure - no CuDv parent
BE352629 Host Adapter ODM Failure on odmget
BE35262A Host Adapter ODM Failure on odminit
BE35262B Host Adapter ODM Initialization Failure
BE35262C Host Adapter ODM Options Error
BE35262D Host Adapter ODM Failure on CuAt close
BE35262E Host Adapter ODM Failure on CuDv close
BE35262F Host Adapter ODM Failure on CuVPD close
BE352630 Host Adapter ODM Failure on CuAt open
BE352631 Host Adapter ODM Failure on CuDv open
BE352632 Host Adapter ODM Failure on CuDv open
BE352633 Host Adapter ODM Failure on CuVPD open
BE352634 Host Adapter ODM Failure on CuAt remove
BE352635 Host Adapter ODM Failure on CuDv remove
BE352636 Host Adapter ODM Failure on CuVPD remove
BE352637 Host Adapter ODM Failure on Storage Map remove
BE352638 Host Adapter ODM Failure on Bus Behavior Table
BE352639 Host Adapter ODM Failure on Storage Map Get
BE35263A Host Adapter ODM Failure on Storage Map Get
BE35263B Host Adapter ODM Failure on Code Read
BE35263C Host Adapter ODM Failure on Flash Read
BE35263D Host Adapter ODM Failure on ODM Update
BE35263E Host Adapter ODM Failure on ODM Update
BE35263F Host Adapter ODM Failure - Location Already Configured
BE352640 Host Adapter ODM Failure - Port CuDv not found
BE352641 Host Adapter ODM Failure - No CuDv
BE352642 Host Adapter ODM Failure - No cpss0 entry in CuDv
BE352643 Host Adapter ODM Failure - No CuDv Info
BE352644 Host Adapter ODM Failure - No CuDv Parent
BE352645 Host Adapter ODM Failure - No Logical Name
BE352646 Host Adapter ODM Failure - No PdDv
BE352647 Host Adapter ODM Failure - Storage Map Operation Failure
BE352648 Host Adapter ODM Failure - Open cpssdd Failure
BE352649 Host Adapter ODM Failure - Options Failure
BE35264A Host Adapter Fence Logical Path
BE35264B Host Adapter Link Incident - BER Exceeded
BE35264C Host Adapter Link Incident - LIR Reported
BE35264D Host Adapter Link Incident - no LIR reported
BE35264E Host Adapter ECC Correctable Error Detected
BE35264F Host Adapter ECC Uncorrectable Error Detected
BE352650 Host Adapter Formatter Error
BE352651 Host Adapter Service Config/Unconfig Failure
BE352652 Host Adapter Config Fail: ADS Null
BE352653 Host Adapter Config Failure: Boot Failure
BE352654 Host Adapter Config Fail: Flash Miscompare
BE352655 Host Adapter Config Fail: Burn Flash Failure
BE352656 Host Adapter Config Fail: Config Checksum
BE352657 Host Adapter Config: CMNGS Update Timeout
BE352658 Microcode failed to configure host adapter card.
BE352659 Host Adapter Config Fail: Device ID Incorrect
BE35265A Host Adapter Config Fail: Early IML Complete
BE35265B Host Adapter Config Failure: POST Failure
BE35265C Host Adapter Config Fail: Config Ready Fail
BE35265D Host Adapter Config Failure: CUB Timeout
BE35265E Host Adapter Config CMNADPGS Read Failure
BE35265F Host Adapter Config SMPVISIBLE Read Failure
BE352660 Host Adapter Config Fail: TCB Allocate Failed
BE352661 Host Adapter Config Fail: SREC Missing
BE352662 Host Adapter Global CRC Error
BE352663 Host Adapter SMP Detected HW Failure
BE352664 Host Adapter Microcode Detected HW Failure
BE352665 Fibre Channel IOCB Response Hardware Failure
BE352666 Fibre Channel Mailbox Response Hardware Failure
BE352667 Fibre Channel Host Adapter: Adapter PCI Error
BE352668 Fibre Channel Host Adapter: Hang Timer for adapter PCI
BE352669 Fibre Channel Host Adapter: Adapter PCI SERR Interrupt
BE35266A Fibre Channel Host Adapter: Interrupt Controller Reserved Bit Error
BE35266B Fibre Channel Host Adapter: Clock Error
BE35266C Fibre Channel Host Adapter: DMA1 Error
BE35266D Fibre Channel Host Adapter: DMA2 Error
BE35266E Fibre Channel Host Adapter: ELA Error
BE35266F Fibre Channel Multiple Port Failure
BE352670 Fibre Channel Single Port Failure
BE352671 Fibre Channel Interrupt Controller Summary With Invalid Data
BE352672 Fibre Channel Interrupt Controller Summary Active
BE352673 Fibre Channel Host Adapter L3 Cache Check
BE352674 Fibre Channel Host Adapter Local PCI Error
BE352675 Fibre Channel Local PCI Error
BE352676 Fibre Channel Host Adapter PBUS Summary Interrupt
BE352677 Fibre Channel PowerPC Exception
BE352678 Fibre Channel Host Adapter SBM Error
BE352679 Fibre Channel Adapter PCI Error
BE35267A Fibre Channel Adapter PCIA Error Interrupt
BE35267B Fibre Channel Clock Error
BE35267C Fibre Channel DMA1 Error
BE35267D Fibre Channel ELA Interrupt
BE35267E Fibre Channel HAMER Error
BE35267F Fibre Channel Host Adapter Hang Timer Interrupt
BE352680 Fibre Channel L3 Cache Check
BE352681 Fibre Channel Local PCI SERR
BE352682 Fibre Channel Local PCIA Error
BE352683 Fibre Channel PBUS Check
BE352684 Fibre Channel Reserved Field Failure
BE352685 Fibre Channel SBM Error Interrupt
BE352686 Host Adapter PowerPC Alignment Error
BE352687 Host Adapter PowerPC Breakpoint Error
BE352688 Host Adapter PowerPC DSI
BE352689 Host Adapter PowerPC Machine Check
BE35268A Host Adapter PowerPC Program Exception
BE35268B Host Adapter PowerPC Floating Point Exception
BE35268C Host Adapter PowerPC Hang Timer Exception
BE35268D Host Adapter PowerPC Instruction Storage Interrupt
BE35268E Host Adapter PowerPC No Data Exception
BE35268F Host Adapter PowerPC Performance Exception
BE352690 Host Adapter PowerPC System Reset
BE352691 Host Adapter PowerPC System Management Interrupt
BE352692 Host Adapter PowerPC System Call Exception
BE352693 Host Adapter PowerPC Thermal Management Interrupt
BE352694 Host Adapter PowerPC Trace Exception
BE352695 Host Adapter PowerPC Machine Check
BE352696 Host Adapter PowerPC Other Exception
BE352697 Host Adapter MPC107 Error
BE352698 Host Adapter MPC107 PCI SERR
BE352699 Host Adapter MPC107 PCI Target PERR
BE35269A Host Adapter MPC107 Memory Read Parity Error
BE35269B Host Adapter MPC107 Flash ROM Write Error
BE35269C Host Adapter MPC107 L2 Copyback Error
BE35269D Host Adapter MPC107 Unknown SRR1 Error
BE35269E Host Adapter MPC107 Interrupt
BE35269F Host Adapter Interrupt Controller No Data
BE3526A0 Host Adapter Interrupt Controller Hang Timer
BE3526A1 Host Adapter Interrupt Controller Reserved Bit Error
BE3526A2 Host Adapter Interrupt Controller HA PCI SERR
BE3526A3 Host Adapter Interrupt Controller Arbiter Error
BE3526A4 Host Adapter Interrupt Controller 60X Bus Address Parity Check
BE3526A5 Host Adapter Interrupt Controller 60X Bus Data Parity Check
BE3526A6 Host Adapter Interrupt Controller Protected Address Write Error
BE3526A7 Host Adapter Interrupt Controller PCIA Error
BE3526A8 Host Adapter Interrupt Controller SBM Interrupt
BE3526A9 Host Adapter Interrupt Controller Formatter Error
BE3526AA Host Adapter Interrupt Controller 60X Bus Error
BE3526AB Host Adapter MM4SC Interrupt
BE3526AC Host Adapter SBM Write Parity Error (FC PCI)
BE3526AD Host Adapter SBM Read Parity Error (FC PCI)
BE3526AE Host Adapter SBM Read/Write Parity Error (FC PCI)
BE3526AF Host Adapter SBM Uncorrectable ECC Error (FC PCI)
BE3526B0 Host Adapter SBM Multiple Error (FC PCI)
BE3526B1 Host Adapter SBM Write Parity Error (FMT PCI)
BE3526B2 Host Adapter SBM Read Parity Error (FMT PCI)
BE3526B3 Host Adapter SBM Read/Write Parity Error (FMT PCI)
BE3526B4 Host Adapter SBM Uncorrectable ECC Error (FMT PCI)
BE3526B5 Host Adapter SBM Multiple Error (FMT PCI)
BE3526B6 Host Adapter SBM Write Parity Error (LP PCI)
BE3526B7 Host Adapter SBM Read Parity Error (LP PCI)
BE3526B8 Host Adapter SBM Read/Write Parity Error (LP PCI)
BE3526B9 Host Adapter SBM Uncorrectable ECC Error (LP PCI)
BE3526BA Host Adapter SBM Multiple Error (LP PCI)
BE3526BB Host Adapter SBM Address Check
BE3526BC Host Adapter SBM Soft Error Threshold Check
BE3526BD Host Adapter SBM Unimplemented Memory Error
BE3526BE Host Adapter PCIA LP PMAC Received Target Abort
BE3526BF Host Adapter PCIA FC PMAC Issued Master Abort
BE3526C0 Host Adapter PCIA LP Memory Region Overlap Error
BE3526C1 Host Adapter PCIA FC PMAC Received Target Abort
BE3526C2 Host Adapter PCIA HA PMAC Issued Master Abort
BE3526C3 Host Adapter PCIA FC Memory Region Overlap Error
BE3526C4 Host Adapter PCIA HA ICR Read/Write Timeout
BE3526C5 Host Adapter PCIA HA PMAC Received Target Abort
BE3526C6 Host Adapter PCIA LP PMAC Issued Master Abort
BE3526C7 Host Adapter PCIA HA Memory Region Overlap Error
BE3526C8 Host Adapter PCIA LP ICR Read/Write Timeout
BE3526C9 First flash image boot failure
BE3526CA EADS Interface Read/Write failure
BE3526CB BIST failure
BE3526CC Flash burn AB word miscompare
BE3526CD Bootstrap loader failure
BE3526CE Fibre Channel port wraptest failure
BE3526CF IOA Slot Freeze Failure during config
BE3526D0 DMA Codeload failure
BE3526D1 Fabric event blames IOA adapter
BE3526D2 Adapter caused too many fabric faults
BE3526D3 Interrupt seen but no EIR presented
BE3526D4 Adapter communication timeout
BE3526D5 Adapter missed a heartbeat
BE3526D6 Host Adapter HA Trace Log (DMA Error Primary)
BE3526D7 Host Adapter HA Trace Log (DMA Error Secondary)
BE3526D8 Host Adapter DMA Timeout
BE3526D9 Host Adapter Microcode Detected HW Failure
BE3526DA Fibre Channel IOCB Status Error
BE3526DB Fibre Channel Mailbox Error
BE3526DC Fibre Channel Diagnostic Failure
BE3526DD Fibre Channel Illegal Parameter Error
BE3526DE Fibre Channel Mailbox Timeout
BE3526DF Fibre Channel IOCB Not Ready Error
BE3526E0 Fibre Channel IOCB Timeout
BE3526E1 Fibre Channel Unexpected Error
BE3526E2 Host Adapter Interrupt Uninstallation Failure
BE3526E3 Host Adapter Interrupt Unregistration Failure
BE3526E4 Host Adapter EADS-X Related Configuration Failure
BE3526E5 Host Adapter Fibre Channel Link Log
BE3526E6 Host Adapter Causing Too Many Indeterminite PHYP Fabric Faults
BE3526E7 Fibre Channel Reset
BE3526E8 Host Adapter Data Loss Event
BE3526E9 Host Adapter Config Fail: Adapter Failed To Become Available
BE3526EA Host Adapter Config Fail: Configuration Failed to Create PCI Windows
BE3526EB Host Adapter PCI Write Failure (Config Space)
BE3526EC Host Adapter PCI Read Failure (Config Space)
BE3526ED Host Adapter Fibre Channel ODM Topology Failure
BE3526EE Host adapter access of unconfigured LUN.
BE3526F8 More than one host adapter encountered a global CRC error.
BE3526F9 More than one host adapter encountered a header LRC error.
BE3526FC Host adapter one shot panic ODD dump.
Table 7. BE36xxxx system reference codes
System reference code Description
BE360010 LPAR host adapter resource manager detected host adapter attribute values mismatched between LPARs.
BE360011 LPAR host adapter resource manager detected HA(or I/O) Port topology attribute values mismatched in ODM between LPARs.
BE360012 IBM.EssSAHARM detected objects missing in the current harvest.
BE360013 IBM.EssSAHARM detected that the user has specified an invalid I/O port topology. Valid values are 0 (Undefined), 1 (FCP), 2 (FCAL), 3 (FICON).
BE360014 Host adapter's CCIN and/or part number value is invalid.
BE360015 Change I/O port topology service action failed because of invalid resource state. The host adapter or target I/O port is not in an available state.
BE360016 LPAR host adapter resource manager object model update failed.
BE360100 Custom Host Adapter error used by PFE group.
BE362600 Bit error rate test failure.
BE362601 Wrap test failure.
BE362602 Host adapter card service action failed due to host adapter CCIN mismatch.
BE362603 Host adapter's owning PCI slot is powered off.
BE362604 Host adapter card could not be discovered/configured.
BE362605 Unable to query PCI slot's power status failed after one or more retries.
BE362606 Health check process detected a host adapter in service mode for more than 72 hours.
BE362607 Health check found fenced host adapter.
BE362608 Health check found one or more fenced I/O ports.
BE362609 Health check found one or more offline I/O ports.
BE36260A Host Adapter's owning PCI slot is not powered off.
BE36260B Host Adapter's owning PCI slot power status could not be obtained - RTAS call failed or PCI slot is missing from device tree.
BE36260C Microcode failed to set service mode on the card during the host adapter install process.
Table 8. BE37xxxx system reference codes
System reference code Description
BE370000 I/O Adapter PCI slot is not powered on.
BE370001 I/O Adapter PCI slot is not powered off.
BE370002 I/O Adapter PCI slot power status could not be obtained. - RTAS call failed or PCI slot is missing from device tree.
BE370003 I/O Adapter could not be discovered and/or configured.
BE370004 I/O tower is not found in device tree as expected.
BE370005 Microcode failed to bring I/O bay enclosure online during install MES operation.
BE370010 IBM.essServerRM detected objects harvested by the Group Leader Node but not the Peer Node or attribute mismatch between Group Leader and Peer harvested attributes.
BE370011 IBM.essServerRM detected objects harvested by the Peer Node but not the Group Leader Node.
BE370012 I/O tower was not found by IBM.essServerRM harvest method after IML (bay is missing)
BE3700A1 LPAR server resource manager(IBM.essServerRM) detected an exception while updating database (system registry) during harvest operation. Database is likely out of sync between LPARs.
Table 9. BE38xxxx system reference codes
System reference code Description
BE382505 Previous PCIe Fabric Error Has Been Recovered.
BE38250C No path through the PCIe fabric exists to this I/O enclosure.
BE382560 CEC P5IOCv2 PHB slot error.
BE382561 CEC 8612 PCIe switch error.
BE382562 I/Oenclosure 8648 PCIe switch error.
BE382563 Degraded PCIe link(s) detected.
BE382564 Unisolated I/Oenclosure fabric event.
BE382565 I/O Adapter caused a fabric error.
BE382566 PCIe I/Oenclosure discovery/configuration failure.
BE382567 PCIe I/Oenclosure discovery/configuration failure: invalid server configuration.
BE382568 PCIe I/Oenclosure discovery/configuration failure: EEH RTAS call failed.
BE382569 PCIe I/Oenclosure discovery/configuration failure: Could not transition slot EEH state to normal.
BE38256A PCIe I/Oenclosure discovery/configuration failure: Local server hardware failure.
BE38256B PCIe I/Oenclosure discovery/configuration failure: Could not initialize path from local server to bay.
BE38256C FPGA update image corrupted on local server.
BE38256D PCIe I/Oenclosure FPGA error.
BE38256E PCIe I/Oenclosure MTMS unknown/invalid.
BE38256F PCIe I/Oenclosure miscable detected.
BE382570 PCIe hub failure detected during discovery/configuration.
BE382571 Error occurred during CEC error data collection.
BE382572 Error occurred during I/O enclosure error data collection.
BE382573 Error occurred during I/O Adapter error data collection.
BE382574 One CEC cannot reach the I/O enclosure. A system failover is required.
BE382575 PCIe I/O Enclosure discovery/configuration failure: I/O Enclosure missing.
BE382577 Error occurred during resource delay reset/delay fence: Escalating to reset/fence.
BE382579 Error occurred trying to take ownership of PCIe I/O enclosure.
BE38257A PCIe Fundamental Reset asserted on I/O enclosure slot.
BE38257B Link to PCIe I/O Enclosure down.
BE38257C RIO Hub Card is garded.
BE38257E Error occurred trying to take ownership of I/O Enclosure after port swap is successful.
BE382580 Host adapter discovery/configuration failure: Fibre Channel Host Card 8Gb plugged into wrong slot.
BE382581 Host adapter discovery/configuration failure: The rack does not support the I/O enclosure Fibre Channel 4Gb host card.
BE382582 Device adapter discovery/configuration failure: The rack does not support the I/O enclosure copper device adapter card.
BE382583 Device adapter discovery/configuration failure: The rack does not support the I/O enclosure optical device adapter card.
BE382584 A Fibre Channel Host card was discovered in the slot that does not support it, is not the type expected, or it does not match the card it is replacing.
BE382588 Page fault escalated to PCIe I/O enclosure as target address is not in this server's window.
BE382589 Interrupt stuck error detected in PCIe Bay.
BE3825A0 PCIe I/O enclosure discovery/configuration failure: Could not initialize path from local server to bay, due to PCIe switch failure.
BE3825A1 PCIe I/O enclosure error.
Table 10. BE39 System Reference Codes
System Reference Code Description
BE392800 Host adapter ASIC data formatter engine error.
BE392801 Error occurred with unused host adapter ASIC hardware.
BE392802 Host adapter ASIC primary PCIe bus error.
BE392803 Host adapter ASIC primary PCIe bus Class B recoverable error.
BE392804 Host adapter ASIC functional island error.
BE392805 MSI occurred from PCIe local bus 1.
BE392806 MSI occurred from PCIe local bus 2.
BE392807 MSI occurred from PCIe local bus 3.
BE392808 Error occurred affecting Fibre Channel port 0
BE392809 Error occurred affecting Fibre Channel port 1.
BE39280A Error occurred affecting Fibre Channel port 0 and 1.
BE39280B Error occurred affecting Fibre Channel port 2.
BE39280C Error occurred affecting Fibre Channel port 3.
BE39280D Error occurred affecting Fibre Channel port 2 and 3.
BE39280E Error occurred affecting Fibre Channel port 4.
BE39280F Error occurred affecting Fibre Channel port 5.
BE392810 Error occurred affecting Fibre Channel port 6.
BE392811 Error occurred affecting Fibre Channel port 7.
BE392812 Error occurred affecting Fibre Channel port 4, 5, 6, 7 and the PCIe switch.
BE392813 Error occurred affecting PCIe switch.
BE392814 Host adapter ASIC SBM function error.
BE392815 Host adapter processor SDRAM error.
BE392816 Default host adapter Class A event.
BE392817 Non IBM supported host adapter SFP detected.
BE392818 Non IBM supported host adapter SFP replaced with supported SFP.
BE392819 Host adapter ASIC primary PCIe bus error indicates a possible fabric fault.
BE39281B Host adapter local bus 1 PCIe recovered Class B error.
BE39281C Host adapter local bus 2 PCIe recovered Class B error.
BE39281D Host adapter local bus 3 PCIe recovered Class B error
BE392820 Error occurred from host adapter processor PCIe bus.
BE392821 Internal error occurred from Host adapter processor.
BE392822 Host adapter failsafe panic.
BE392824 Unable to reconfigure host adapter PCIe bus.
BE392829 T10 DIF CRC error on write operation.
BE392830 T10 DIF CRC error on read operation in single host adapter.
BE392831 T10 DIF CRC error on read operation in multiple host adapter.
BE392833 T10 DIF REF error on write operation.
BE392834 T10 DIF REF error on read operation in single host adapter.
BE392835 T10 DIF REF error on read operation in multiple host adapter.
BE392840 Host adapter panic occurred.