DS8000 Service Documentation Version 6.3.3

FSPSP02

This procedure is for boot failures that end very early in the boot process. This error path is indicated when the SRC data words are scrolling automatically through the CEC enclosure control panel functions 11, 12, and 13, and the CEC enclosure control panel interface buttons are not responsive.

Procedure

  1. Reset the service processor card. See MAP4810 Resetting the service processor (FSP).
  2. Did resetting the service processor card fix the problem?
    • Yes, you have fixed the problem but you should call your next level of support. Further incidents might be prevented by installing the most recent version of Licensed Internal Code (LIC).
    • No, continue with step 3.
  3. Exchange the CEC enclosure service processor card. If it is listed in the serviceable event FRU list, then exit this procedure and replace it using the serviceable event. If it is not listed in the serviceable event FRU list, refer to MAP1230 Replace a FRU without using a serviceable event and then exit this MAP. If the problem persists call your next level of support for assistance. This problem might be resolved by installing the most recent version of Licensed Internal Code (LIC).

What to do next

This ends the procedure.