DS8000 Service Documentation Version 6.3.3
PWR1918
The server (managed system) detected an error in the power system.
PWR1918 Section-1
About this task
Note: Storage complex repair actions must always be managed from the
management console. To replace any FRUs identified in this procedure, use . If the FRUs are listed in
this or another Serviceable Event, select them from there.
Use the table that follows to determine the failing FRU.
| Reference code | Description/Action |
|---|---|
| 1xxx 1611, 1612, or 1613 | Processor voltage regulator 1 at location Un-P2-C3 is failing. Replace it. |
| 1xxx 1621, 1622, or 1623 | Processor voltage regulator 2 at location Un-P2-C4 is failing. Replace it. |
| 1xxx 1631, 1632, or 1633 | Processor voltage regulator 3 at location Un-P2-C5 is failing. Replace it. |
| 1xxx 2602 and all other reference codes | Failing processor voltage regulator card cannot be determined. Replace processor voltage regulator cards sequentially. If 1xxx 2602 appears again, replace CEC enclosure system processor backplane assembly Un-P2. |
| 1xxx 8450 | Fewer processor voltage regulator cards than processor cards are installed. |
| 1xxx 8451 | Too few processor voltage regulator cards installed. |