DS8000 Service Documentation Version 6.3.3
MAP31B0 SRCs BE34002B and BE340074 No available spares for DDM repair
A DDM that has failed cannot be repaired until other failed
DDMs on this same loop are repaired first.
MAP31B0 Section-1
Procedure
- Use the following information to repair this serviceable event:
- Both DDM spare drives on this loop have already been used by the
two DDMs that have failed.
- A third DDM drive on the same loop has failed, but there is no
available spare drive to use.
- All the failing DDM drives for this loop are listed in the serviceable
event FRU list.
- Ensure that you repair the DDM drives in the
order that they are listed in the FRU list starting at the top.
Note: The last DDM drive in the FRU list can only be repaired
after at least one DDM spare has been made available by repairing
a prior DDM drive in the FRU list.