DS8000 Service Documentation Version 6.3.3
MAP21C1 CEC complex 2 I/O backplane assembly
Procedure
- Determine the machine type/model/serial (MTMS) number of the top CEC enclosure in Rack-1.
- Does this storage facility have
a Rack-2?
- Yes, go to step 3.
- No, the controlling CEC enclosure for CEC complex 2 is the bottom CEC enclosure in Rack-1. Go to step 4.
- Does Rack-2 have CEC enclosures?
- Yes, the controlling CEC enclosure for CEC complex 2 is the top CEC enclosure in Rack-2. Go to step 4.
- No, the controlling CEC enclosure for CEC complex 2 is the bottom CEC enclosure in Rack-1. Go to step 4.
- The MTMS of the controlling CEC enclosure for CEC complex 2 is on the front of the CEC enclosure, at the far right, between the rack mounting screws (in a vertical orientation).
- Use the Exchange FRU process to select and replace the CEC complex I/O backplane assembly.
- From the navigation area, click Storage Facility Management > storage facility.
- From the bottom Task area, click Exchange Parts. Select the exchange option that contains the FRU to be exchanged. A window opens and displays the enclosures.
- Select the Enclosure Location Code, and then click Show FRUs.
- Select the FRU Location Code, and then click Exchange FRU.
Related tasks: