MAP2160 Power system Identify LED failure
A rack or FRU Identify LED can fail to light or be lit when a repair is not active.
About this task
MAP2160 Section-1
Procedure
| Symptom | Go to: |
|---|---|
| Rack Identify LED is off and should be flashing | MAP2160 Section-2 |
| FRU Identify LED is blinking and should be off | MAP2160 Section-3 |
| FRU Identify LED is lit and should be off | MAP2160 Section-4 |
| LED does not light | MAP2160 Section-5 |
MAP2160 Section-2
About this task
Procedure
MAP2160 Section-3
The Identify LED is blinking and should be off. Each FRU Identify LED is driven by a source external to the FRU that contains the LED. When the Identify LED is flashing, a failure is indicated. A failure at the source that drives the LED is indicated because the source provides the flash timing function.
Procedure
MAP2160 Section-4
The FRU Identify LED is lit and should be off. Each Identify LED is driven by a source external to the FRU that contains the LED. If a repair action is not being taken for the FRU, the LED should be off. It the LED is on solid, a failure is indicated. When the LED is on solid, the failure can be at the source of control, the FRU that contains the LED of the cable that connects the two.
Procedure
- FRU with failing Identify LED.
- FRU that provides Identify LED control.
- Cable that connects the above two FRUs if applicable.
MAP2160 Section-5
The LED does not light.