DS8000 Service Documentation Version 6.3.3
B70069C7 B70069C7
Explanation
Platform LIC detected an error
Response
Abnormal or unexpected HSL OptiConnect disconnection from a
remote system or partition.
The local system or partition disconnected from a remote
system or partition due to an unexpected event or failure.
Licensed Internal Code will attempt to recover from the
error. Intervention at the local or remote system or
partition might be required.
Possible causes include time out, hang, or hardware failure.
The problem may be with the local system or partition or the
remote system or partition.
If a complete RIO or HSL loop did not exist before this
error
occurred, the cause of this error might be a failure or
power down in a RIO or HSL component between the local
system
or
partition and the remote system or partition. Check for SRCs
with FRUs that indicate problems with the following:
- RIO or HSL cables
- The RIO or HSL I/Oidge
- Power in an expansion I/O tower or unit on this loop
Problem determination
No action is required.