DS8000 Service Documentation Version 6.3.3
B70069C6 B70069C6
Explanation
Platform LIC detected an error
Response
Abnormal or unexpected HSL OptiConnect disconnection from a
remote system or partition.
The local system or partition disconnected from a remote
system or partition due to an unexpected event or failure.
The problem, which most likely originates with the remote
system or partition, probably requires intervention at the
remote system. Examine both the local and remote HSL
OptiConnected systems or partitions for problems on this
RIO or HSL
loop.
Possible reasons include: A fatal software or hardware error
in the remote system or partition, or a power failure in the
remote system.
If a complete RIO or HSL loop did not exist before this
error
occurred, the cause of this error might be a failure or
power down in a RIO or HSL component between the local
system
or
partition and the remote system or partition. Check for a
problem with the following:
- A RIO or HSL cable
- The RIO or HSL I/Oidge
- Power in an expansion I/O tower or unit on this loop
Problem determination
No action is required.