DS8000 Service Documentation Version 6.3.3

B1812A61   

Explanation

Throttling occurred in nominal or turbo mode due to the bulk power limit being reached with both power supplies good. An event occurred and the thermal/power management firmware may reduce performance (either memory throttling and/or a drop in processor frequency).

Response

If this is a tracking event, no service actions are required. Otherwise, use the FRU and procedure callouts detailed with the SRC to determine service actions.